Chemical kinetics: rate laws, half-life and Arrhenius
Thermodynamics says which way a reaction goes; kinetics, how fast. A strongly favored reaction can take years and a barely favored one, microseconds. This topic explains how the rate of a reaction is defined and measured, what a rate law and its order are, how the zero-, first- and second-order laws are integrated and what the half-life says, how the order is found from data (the graphical method and the method of initial rates), how the rate constant changes with temperature (the Arrhenius equation) and what a catalyst does. Every number comes from the chemical kinetics simulator, and at the end there are ten worked examples that open in it.
Reaction rate
The rate of a reaction says how much the concentration of a species changes per unit time. Reactants are used up (their concentration falls) and products are formed (theirs rises), and not all at the same pace: it depends on the coefficients of the equation. For the rate of the reaction to be a single, positive number, each change is divided by its stoichiometric coefficient and the sign of the reactants is changed. For :
In the decomposition 2 N₂O₅ → 4 NO₂ + O₂, if N₂O₅ disappears at M/s, NO₂ appears at M/s (four for every two) and O₂ at M/s (one for every two); the rate of the reaction is M/s. The units are concentration per time: M/s, that is, mol·L⁻¹·s⁻¹ (for a gas you can also work with partial pressures, in atm/s or kPa/s).
Average and instantaneous rate
With two measurements you get the average rate, : the slope of the secant line joining those two points of the [A]–t curve. The instantaneous rate is the limit of that slope as , the slope of the tangent, . Since the curve flattens as the reactant is used up, the rate keeps falling: the one at the initial instant, the initial rate , is the largest.
How is [A] measured while the reaction goes on? With any property that depends on it and can be read without stopping the reaction: the absorbance of a colored species (by the Beer–Lambert law the absorbance is proportional to the concentration), the total pressure of a gas at constant volume, the conductivity of a solution with ions or the optical rotation, as in the inversion of sucrose. With partial pressures the same laws hold as with concentrations: that is why the tool's «Concentration» list also has atm, kPa, mmHg and bar.
Rate law and reaction order
Experimentally, the rate depends on the concentrations of the reactants (sometimes also on those of a product or of a catalyst) as a power of each one:
- and are the partial orders and , the overall order. They are measured: they are not read from the balanced equation.
- is the rate constant: it depends on temperature (and on the catalyst), not on the concentrations.
- An order can be 0 (the rate does not depend on that species), fractional (½) or even negative (a species that slows the reaction down).
Three reactions from the tool's examples («Initial rates» view, exercise data) show that the orders are not the coefficients:
| Reaction | Rate law (from the data) | Orders = coefficients? |
|---|---|---|
| 2 NO + O₂ → 2 NO₂ | , order 3 | Yes, in this case |
| (CH₃)₃CBr + OH⁻ → (CH₃)₃COH + Br⁻ | , order 1 | No: order 0 in OH⁻ |
| BrO₃⁻ + 5 Br⁻ + 6 H⁺ → 3 Br₂ + 3 H₂O | , order 4 | No: the coefficients are 1, 5 and 6 |
The reason lies in the mechanism. An overall equation is usually the sum of several elementary steps, actual collisions between molecules. Only in an elementary step does the order match the number of molecules that collide (its molecularity: uni-, bi- or, very rarely, termolecular), and the slowest step, the rate-determining step, sets the rate of the whole. In the second reaction the slow step is the breaking (CH₃)₃CBr → (CH₃)₃C⁺ + Br⁻; OH⁻ reacts afterwards with the carbocation, in a fast step, and that is why adding more OH⁻ speeds nothing up.
The units of k
Since is always in concentration/time, the units of depend on the overall order : concentration times time. The tool writes that unit in the list of for each order and converts it if the time unit of and that of differ.
| Overall order | Law | Units of k (M and s) |
|---|---|---|
| 0 | ||
| ½ | ||
| 1 | ||
| 2 | or | |
| 3 |
Integrated rate laws
The rate law is a differential equation: it says how [A] changes, not what it is. To know how much is left after a time it has to be integrated. With a single reactant (or with the others in excess), , and the variables separate: everything with [A] on one side and time on the other, integrated from , where .
Zero order
[A] falls in a straight line, with slope , until it runs out at ; from then on the law no longer holds ([A] cannot be negative) and the tool says so. It happens when the rate is limited by something other than the concentration: a saturated catalytic surface (ammonia on platinum or on hot tungsten), a saturated enzyme or the light that arrives in a photolysis.
First order
It is an exponential: in equal time intervals the same fraction is always used up. That is why against is a straight line of slope , and the fraction left, , does not depend on : using up half takes the same time starting from 1 M or from 0.001 M. Radioactive decays, many decompositions (N₂O₅, SO₂Cl₂) and the elimination of many drugs are first order.
Second order
Now the straight line is against , with slope . Compared with a first-order law with the same first half-life, it falls faster at the start and then much more slowly: the rate drops with the square of [A]. It is the law of 2 NO₂ → 2 NO + O₂, of the combination of two radicals and of A + B when .
A + B with different concentrations
If and each A uses up one B, . With , the amount that has reacted, the law is with and . It splits into partial fractions, , and integrating gives:
The limiting reactant tends to zero and the other one, to what is left over. If the formula would give 0/0; the tool then uses the second-order law of one reactant, , and says so. If is much larger than , [B] hardly changes and the law becomes pseudo-first order with : with M, M and , after 60 s the exact law gives M and the first-order one with , M: a 0.2% difference. That is how many second-order laws are measured: with one reactant in large excess (the isolation method).
| Order | Rate law | Integrated law | Straight line | Slope | Half-life |
|---|---|---|---|---|---|
| 0 | [A] against t | ||||
| 1 | ln[A] against t | ||||
| 2 | 1/[A] against t | ||||
| A + B | ln([B]/[A]) against t | depends on [A]₀ and [B]₀ |
Half-life
The half-life is the time it takes [A] to fall to half. It comes from putting into each integrated law:
Only the first-order one is constant: every half-life lasts the same, whether it is the first or the tenth. In zero order each one lasts half as long as the previous one (half as much is left to use up, at the same pace) and in second order, twice as long (the pace falls with the square of the concentration). Whether successive half-lives stay the same, get shorter or get longer is a quick test of the order.
In first order, after half-lives of the initial amount is left. The time for 90% to react is , and for 99%, :
| Half-lives | Left | Reacted |
|---|---|---|
| 1 | 50 % | 50 % |
| 2 | 25 % | 75 % |
| 3 | 12.5 % | 87.5 % |
| 3.322 | 10 % | 90 % |
| 5 | 3.125 % | 96.875 % |
| 6.644 | 1 % | 99 % |
| 10 | 0.09766 % | 99.90 % |
That table explains carbon-14 dating: a living organism keeps the atmosphere's proportion of ¹⁴C and, when it dies, the ¹⁴C decays with a half-life of 5730 years (the value in the tool's example). If 25% is left, two half-lives have passed: 11,460 years (example 2). For any other percentage, .
The half-life in the simulator
In the «Integrated law» view the half-life is one more datum: type the «Half-life t½» and the tool gets k (in first order that is enough; in zero and second order [A]₀ is also needed, because t½ depends on it), or the other way round. The tile reminds you under the value: «does not depend on [A]₀» in first order and «depends on [A]₀» in zero and second order. In the graph of [A] against t, the dotted lines mark t½, 2t½ and 3t½ in first order; t½ and 1.5t½ in zero order (where it has almost run out), and t½, 3t½ and 7t½ in second order (the first three half-lives add up to 1 + 2 + 4 = 7).
The order from data: the graphical method
With a table of [A] at several times, the most direct way to find the order is to try the three linear forms: compute [A], ln[A] and 1/[A], plot each against t, and the one that comes out straight gives the order. Its slope gives k: minus the slope in zero and first order, the slope itself in second order. The intercept gives the [A]₀ the line “sees”.
“Comes out straight” is measured with the least-squares line of each column and its coefficient of determination :
is a perfect line. With the data of the N₂O₅ decomposition (example 6), the three graphs give = 0.9532 (zero order), 0.99999 (first order) and 0.9567 (second order): only ln[A] is straight. Its slope is s⁻¹, so s⁻¹, and the intercept, M, is the [A]₀ of the line.
Beware of low conversion
Any smooth curve looks straight over a short stretch. With only the first three measurements of example 6 (up to 600 s, 31% conversion) the three graphs give R² = 0.9969, 0.999994 and 0.9974, and they are hard to tell apart. That is why you should measure up to two or three half-lives, and the tool warns you when the conversion is below 50% («Only 31 % conversion was measured…») or when two orders give almost equally good lines.
The residuals
R² is not enough: you have to look at the residuals, data minus line, in time order. If the line describes the data well, they scatter at random (+ − + + − …); if the data curve, they form an arc: first one sign, then the other, then the first again. In the tool's example «Data that are not of order 0, 1 or 2», the best line is the second-order one (R² = 0.9800, far from 0.999) and its residuals go + + + − − − − +: the data follow none of the three whole orders (they may be of a fractional order, of two paths at once or have a large error). The tool warns you with those same signs.
The method of initial rates
With several reactants, a t–[A] table of one of them is not enough. Several experiments are run changing the initial concentrations, and in each one the rate at the start, , is measured, while the concentrations are still the known initial ones (and the products, which might take part, are not there yet). If from one experiment to another only [A] changes, the ratio of the two rates depends only on its order:
The three experiments of example 7 (2 NO + O₂ → 2 NO₂, exercise data):
| Exp. | [NO] (M) | [O₂] (M) | v₀ (M/s) |
|---|---|---|---|
| 1 | 0.010 | 0.010 | 2.5×10⁻⁵ |
| 2 | 0.020 | 0.010 | 1.0×10⁻⁴ |
| 3 | 0.010 | 0.020 | 5.0×10⁻⁵ |
From 1 to 2, [NO] doubles and is multiplied by 4 = 2²: second order in NO. From 1 to 3, [O₂] doubles and doubles: first order in O₂. The law is , of overall order 3, and every experiment gives .
A useful shortcut: doubling a concentration multiplies the rate by , that is, ×1 in zero order, ×1.414 in order ½, ×2 in first order and ×4 in second order. Taking logarithms, : on logarithmic scales each order is a straight line of slope .
With noisy data, or when there are no two experiments in which only one reactant changes, the tool fits by least squares with all the experiments, rounds each order to the nearest half-integer (and shows the unrounded value) and computes k in each experiment. In the example «Noisy measurements (five experiments)» the orders come out 0.944 and 1.96, they are rounded to 1 and 2, and the five k values differ from their mean, 0.2504 M⁻²·s⁻¹, by 3.8% at most. If an order is far from an integer or a half-integer, the tool warns you.
Temperature: the Arrhenius equation
Almost every reaction speeds up when heated, and a lot; what changes with temperature is k. The dependence is described by the Arrhenius equation:
- , the activation energy (J/mol or kJ/mol): the energy barrier the reactants must overcome to turn into products.
- , the frequency factor (or pre-exponential factor), with the same units as k: how many collisions happen, and with the right orientation.
- J/(mol·K) and in kelvin. The tool uses R = 8.314462618 J/(mol·K), the exact SI value since 2019.
The factor is the fraction of collisions with enough energy to react. That fraction is tiny and grows very fast with temperature: that is why a modest rise in temperature multiplies the rate.
The linear form and the two-point form
Taking logarithms, the equation is a straight line in 1/T:
The Arrhenius plot, against , has slope and intercept . With only two temperatures the two equations are subtracted and cancels:
With k at 25 °C and at 50 °C you get Eₐ = 99.46 kJ/mol (example 8); with Eₐ and one k you get k at another temperature, and with Eₐ and two k, the temperature at which one of them is reached. With more than two temperatures, the least-squares line of the Arrhenius plot uses all the data and tells, through its R², whether they follow the equation:
How much does heating by 10 °C speed things up?
The rule “twice as fast every 10 °C” only holds for one particular activation energy. Between 25 and 35 °C, the ratio k(35 °C)/k(25 °C) depending on Eₐ:
| Eₐ (kJ/mol) | k(35 °C)/k(25 °C) |
|---|---|
| 25 | 1.387 |
| 50 | 1.924 |
| 52.95 | 2 |
| 100 | 3.703 |
The higher the barrier, the more sensitive the reaction is to temperature: its Arrhenius line is steeper. With Eₐ = 50 kJ/mol, doubling the rate takes going from 25 to 35.61 °C.
Catalysts
A catalyst speeds up a reaction without being used up: it opens another path, with other elementary steps, whose highest barrier is lower than that of the path without it. If the frequency factor does not change much, at the same temperature the constant grows by the factor
Lowering the barrier from 80 to 50 kJ/mol at 37 °C (example 9) multiplies k by 1.128×10⁵: what would take a day without the catalyst takes less than a second with it. Without the catalyst you would have to heat up to 496.24 K (223.09 °C) to get the same k. That is how enzymes work at body temperature.
- It does not change the equilibrium. It lowers the forward and the reverse barrier equally, so the equilibrium constant, the ratio of the two rate constants, does not change: equilibrium is just reached sooner.
- Homogeneous or heterogeneous. In the same phase (an acid in solution) or a solid surface (platinum, iron, zeolites). On a saturated surface the rate no longer depends on the concentration: zero order, like ammonia on platinum (example 3).
- Enzymes. They are very specific biological catalysts; with a lot of substrate they also saturate and go to zero order.
- Inhibitors. They do the opposite. If you type an «Eₐ with catalyst (optional)» higher than Eₐ, the tool warns that it would be an inhibitor.
How to use the simulator
The simulator is in «Chemistry» → «Reactions» → «Chemical kinetics». On the left is the «Data» panel: at the top, «What do you want to compute?» with the four views, and below it the «Examples» dropdown («Choose…») with the examples of the open view. On the right come the result (a card with the name of the view), the «Graphs» and the «Step by step», with the «Detailed solution (PDF)» button, which opens the same solution written with formulas, ready to print.
| View | What for | What you type | What you get |
|---|---|---|---|
| «Integrated law» | how much is left, how long it takes, k or the half-life | the order and any three data | the rest, the rates and two graphs |
| «Order from data» | the order and k from a t–[A] table | one measurement per row | the three lines with their R², the order, k, [A]₀ and t½ |
| «Initial rates» | the rate law with several reactants | one experiment per row: initial concentrations and v₀ | each order, the overall order, k and the law |
| «Arrhenius» | Eₐ, A, k at another temperature, the effect of a catalyst | two temperatures with their k, or a k–T table | Eₐ, A, k₂/k₁ or the predicted k and the Arrhenius plot |
«Integrated law»
- In «1. The reaction» choose «Order 0», «Order 1», «Order 2» or «A + B»; below you see the rate law, its integrated form and the half-life of that order.
- In «2. Units» choose the «Concentration» (M, mM, µM or a pressure) and the «Time» (s, min, h, d or yr). The times you type, t and t½, are in that unit.
- In «3. What you know» type what the problem gives and leave empty what you are looking for (the empty field reads «unknown»): «[A]₀», «[A] at t», «Time t», «Half-life t½», «Rate constant k» and «Percentage», which can be «left» or «reacted». The unit of k has its own list: if k comes in s⁻¹ and the time in minutes, choose s⁻¹ in the k list and the tool converts (it shows it in the «Step by step»).
- With three data the rest comes out. If you type a fourth one, it is checked: «Extra datum: … agrees» if it fits, or «The data do not agree» if not, and then the results use the other data. If something is missing, «Not enough data» appears with examples of what to type. The counter next to the title says how many data it uses; «Clear» erases them.
- Each tile says below whether it is «given» or «computed». «Left» gives the percentage left and the one that reacted; «Initial rate v₀» and «Rate at t» apply the rate law.
- In «Graphs» there are [A] against t, with the half-lives marked and the point at time t, and the linear form of that order: ln[A] or 1/[A] against t, and in zero order the rate against t.
«Order from data»
- Choose the units and type in «2. Measurements: time and reactant concentration» one t and one [A] per row. «+ Measurement» adds a row and «Paste 2 columns» takes two columns copied from a spreadsheet («Use these data»).
- The tool draws the three lines and keeps the one with R² closest to 1 (the tile says «best fit»). In «3. Order used for k» you can force order 0, 1 or 2 instead of «The best fit» to see what k each one would give; the tile then says «chosen».
- Tiles: «Reaction order» (with its law and R²), «Rate constant k» with its standard error, «[A]₀ from the line» and «Half-life t½». In the «Step by step», the table with the columns t, [A], ln[A] and 1/[A], the three lines and the signs of the residuals.
«Initial rates»
- In «1. Reactants» choose «1 reactant», «2 reactants» or «3 reactants» and type their names («Name of #1»…); in «2. Units», the concentration and the «Time (rate)».
- In «3. Experiments», one row per experiment: the initial concentrations and v₀ («+ Experiment» adds another). Ideally change only one reactant at a time.
- Tiles: «Order in …» for each reactant (with the «unrounded» value), «Overall order», «Rate constant k» (the mean of the experiments) and «Rate law».
«Arrhenius»
- In «1. Starting data» choose «Two temperatures» or «k–T table»; in «2. Units», the «Temperature» (°C or K), the «Energy» (kJ/mol, J/mol or kcal/mol) and the «Units of k», which are only for writing them (the ratio k₂/k₁ has no units).
- With «Two temperatures»: of k₁, T₁, k₂, T₂ and the «Activation energy Eₐ», four give the fifth, and also the «Frequency factor A». If you only know how much faster the reaction is, type k₁ = 1 and k₂ = the ratio. The «Eₐ with catalyst (optional)» adds the tile «With catalyst, at T₁» with the factor k_cat/k and, in «Graphs», the energy profile.
- With «k–T table»: in «3. Constant at each temperature», one T, k pair per row («+ Temperature»); you get the Arrhenius line with Eₐ (and its standard error), A and R², and with «Predict k at temperature (optional)», the k at another temperature.
Common mistakes
- Reading the orders from the coefficients of the balanced equation: that only holds for an elementary step; the rate law is measured.
- Mixing time units: k in s⁻¹ with t in minutes. In the tool choose the unit of k in its list; by hand, convert first (5.1×10⁻⁴ s⁻¹ = 0.0306 min⁻¹).
- Using °C in the Arrhenius equation: T goes in kelvin (25 °C = 298.15 K). With °C, Eₐ comes out absurd.
- Writing Eₐ in kJ/mol with R = 8.314 J/(mol·K) without converting: an error of a factor of 1000.
- Using ln 2/k as the half-life of a zero- or second-order reaction: that formula is only first order. In zero and second order the half-life depends on [A]₀.
- Thinking that in first order the reactant runs out: [A] = [A]₀e⁻ᵏᵗ gets closer to 0 without reaching it. In zero order it does run out, at t = [A]₀/k, and the law no longer holds afterwards.
- Confusing the rate of disappearance of A with the rate of the reaction when the coefficient is not 1 (with 2 NO₂, −d[NO₂]/dt = 2v).
- Choosing the order from an R² of 0.99 with little conversion: also look at the residuals and measure up to two or three half-lives.
- Confusing the pseudo-first-order k (k′ = k[B]₀, in s⁻¹) with the second-order one (in M⁻¹·s⁻¹).
- Believing a catalyst changes the equilibrium or the yield: it only makes it come sooner.
Worked examples
Example 1How much is left (first order, with a unit change)
Solution
- Units first: min⁻¹ (or else 10 min = 600 s).
- M: 73.64% is left.
- min.
- 90% reacting means is left: min, that is, 3.322 half-lives.
Solve it in Simuveliq
- The button opens N₂O₅ (1st order): how much is left after 10 min: «Order 1», the time in min and k in s⁻¹ in its list. The tiles give «[A] at time t» 0.1841 M, «Half-life t½» 22.65 min and «Left» 73.64 %; the k tile also shows 0.0306 min⁻¹.
- For 90%: erase the «Time t», type 90 in «Percentage» and choose «reacted». The computed time is 75.25 min.
Example 2Carbon-14 dating
Solution
- Decay is first order: yr⁻¹.
- is left: years.
- Check: , two half-lives: years. No concentration is needed: in first order only the fraction matters.
Solve it in Simuveliq
- Carbon-14: age of a sample with 25 % of its ¹⁴C: «Order 1», the time in years, the «Half-life t½» 5730 and the «Percentage» 25 «left». It gives «Time t» 11460 yr and k = 1.21×10⁻⁴ yr⁻¹. A note says that [A]₀ and [A] cannot be computed: they are not needed here.
Example 3Zero order: when it runs out
Solution
- Zero order: ; it runs out when : min.
- min. The second half-life (from 0.25 to 0.125 M) lasts min: half as long.
- The rate is the same all the time, v = k = 0.012 M/min, until it runs out; then it drops to 0.
Solve it in Simuveliq
- Zero order (NH₃ on platinum): when it runs out comes with «[A] at t» = 0: it gives «Time t» 41.67 min, «Half-life t½» 20.83 min and «Rate at t» 0. The second graph, the rate against time, is a step: constant, then zero.
- For the second half-life type 0.25 in «[A]₀»: the «Half-life t½» becomes 10.42 min.
Example 4Second order: time to reach a concentration
Solution
- : s.
- s. The second starts at 0.025 M and lasts s, twice as long; the third, s.
- Rates: M/s and at the end M/s, 25 times less because [A] fell 5 times.
Solve it in Simuveliq
- 2nd order (2 NO₂): time to reach 0.010 M: «Time t» 148.1 s, «Half-life t½» 37.04 s, «Initial rate v₀» 0.00135 M·s⁻¹ and «Rate at t» 5.4×10⁻⁵ M·s⁻¹. The linear form is 1/[A] against t.
- Type 0.025 in «[A]₀»: the «Half-life t½» becomes 74.07 s.
Example 5A + B with different concentrations
Solution
- In minutes: , and .
- With : , so M.
- M. 26.29% of the ester, the limiting reactant, is left; the NaOH tends to 0.010 M.
- Half-life of the ester: min.
Solve it in Simuveliq
- A + B (ester saponification), [A]₀ ≠ [B]₀: «[A] at time t» 0.005257 M, «[B] at time t» 0.01526 M, «Half-life of A» 4.359 min and «Left» 26.29 %. The graph has both curves, and the linear form is ln([B]/[A]) against t.
- Type 0.030 in «[A]₀» too: with [A]₀ = [B]₀ the tool switches to the second-order law of one reactant and says so («the law is the second-order law of one reactant»).
Example 6The order from a table (graphical method)
Solution
- The two new columns: ln[A] = −3.912, −4.098, −4.283, −4.474, −4.656, −5.028 and −5.399; 1/[A] = 50.00, 60.24, 72.46, 87.72, 105.26, 152.67 and 221.24 M⁻¹.
- The three lines: [A] with R² = 0.9532; ln[A] with R² = 0.99999; 1/[A] with R² = 0.9567. It is first order (the figure in the section on the graphical method).
- : s⁻¹ and M.
- s (18.64 min). It was measured up to 77.4% conversion, more than two half-lives: the order is reliable.
Solve it in Simuveliq
- N₂O₅ decomposition (first-order data), in the «Order from data» view: «Reaction order» 1 («best fit», R² = 0.99999), «Rate constant k» 6.197×10⁻⁴ s⁻¹ and «Half-life t½» 1118 s. The three graphs carry their R² and the chosen one is marked («the straightest»).
- Press 2 in «3. Order used for k»: k = 0.07023 M⁻¹·s⁻¹, the tile says «chosen», a note reminds you «You chose order 2; the best fit is order 1» and a warning says the residuals form an arc.
Example 7Initial rates with two reactants
Solution
- Experiments 1 and 2: [NO] ×2 and ×4: .
- Experiments 1 and 3: [O₂] ×2 and ×2: .
- ; all three experiments give the same. Overall order 3, hence the units.
- With 0.050 M of each: M/s.
Solve it in Simuveliq
- 2 NO + O₂ → 2 NO₂ (two reactants), in «Initial rates»: «Order in NO» 2, «Order in O₂» 1, «Overall order» 3, «Rate constant k» 25 M⁻²·s⁻¹ and «Rate law» v = k[NO]²[O₂]. The «Step by step» shows each ratio and the table with the k of each experiment.
Example 8Activation energy from two temperatures
Solution
- In kelvin: K and K; K⁻¹, and .
- J/mol kJ/mol.
- s⁻¹.
- At 37 °C (310.15 K), with the two-point form from 25 °C: s⁻¹.
Solve it in Simuveliq
- Eₐ and A from k at 25 °C and at 50 °C («Arrhenius» view, «Two temperatures»): «Activation energy Eₐ» 99.46 kJ/mol, «Frequency factor A» 9.304×10¹² s⁻¹ and «Ratio k₂/k₁» 22.29.
- For k at 37 °C: erase k₂, type 99.46 in «Activation energy Eₐ» and 37 in T₂. The tile «k at T₂» gives 1.653×10⁻⁴ s⁻¹.
Example 9The effect of a catalyst
Solution
- K.
- .
- The same k without the catalyst requires the same : K, that is, 223.09 °C.
Solve it in Simuveliq
- Catalyst: Eₐ drops from 80 to 50 kJ/mol at 37 °C: the tile «With catalyst, at T₁» gives ×112800, and «Graphs» shows the energy profile with both barriers. The «Step by step» also computes the equivalent temperature, 496.24 K. Without k₁ or k₂, neither A nor any k can be computed, and a note says so.
Example 10Arrhenius with a k–T table
Solution
- The table of the Arrhenius plot: = 3.411, 3.299, 3.193, 3.095 and 3.002 K⁻¹; = −6.190, −5.388, −4.620, −3.917 and −3.237.
- Least-squares line: , with .
- kJ/mol and s⁻¹.
- At 45 °C (318.15 K): s⁻¹, between the k measured at 40 and at 50 °C.
Solve it in Simuveliq
- Table of k at five temperatures («Arrhenius» view, «k–T table»): «Activation energy Eₐ» 59.94 kJ/mol with its standard error (± 0.16), «Frequency factor A» 9.78×10⁷ s⁻¹, «R²» 0.999979 and «k at 45 °C» 0.0141 s⁻¹.
- Type 80 in «Predict k at temperature (optional)»: k = 0.1332 s⁻¹, and the tool warns that «the predicted k is an extrapolation».