Simuveliq

Column buckling calculator

Pick the section (bar, tube, rectangle, box or I-shape), the material, the supports on each axis and the bracing, and get the critical buckling load, the slenderness, the effective length factor K from finite elements, the buckled shape and the safety factor by Euler, Johnson, AISC 360 or the secant formula for eccentric loads.

What you can do

Frequently asked questions

When to use Euler and when Johnson?

Euler applies to long columns (slenderness above Cc = π√(2E/Fy)); intermediate columns use Johnson's parabola.

What is the effective length?

The length of an equivalent pinned column: Le = K·L, where K depends on the supports (0.5 fixed–fixed, 1 pinned–pinned, 2 fixed–free).

Guide: column buckling

A slender column in compression does not usually fail because the material crushes, but because it suddenly bends sideways: this is buckling, a loss of stability that can happen at stresses well below yield. This guide explains Euler's critical load, the effective length factor, when Johnson must be used instead of Euler, and works an example.

Euler's critical load

For a perfectly straight column of elastic material with a centered load, the load at which it stops being stable is

Pcr = π² · E · I / (K · L)²

E is the modulus of elasticity, I the moment of inertia of the section about the axis it buckles around, L the length and K the effective length factor, which depends on the supports. Le = K·L is the length of an equivalent pinned column.

K factor by end conditions

These are theoretical values. Design codes such as AISC recommend somewhat larger values for fixed ends, because in practice no fixed end is perfect. The calculator finds K by solving the stability problem with finite elements using the actual supports and braces, and with the "recommended K" option it uses the AISC design values for the classic cases.

Slenderness and buckling axis

Slenderness is Le/r, where r = √(I/A) is the radius of gyration. Dividing Pcr by the area gives the critical stress σcr = π²E/(Le/r)². The column buckles about the axis with the largest Le/r: for an I-shape that is almost always the weak axis y–y, unless it is braced. A brace at mid-height halves Le about that axis and quadruples its critical load.

Short, intermediate and long columns

Euler only holds if the column buckles elastically, that is, if σcr stays below the yield strength Sy. The transition slenderness used by Shigley is

Cc = √(2π²E / Sy)

If Le/r > Cc, the column is long and Euler applies. If it is smaller, the material starts to yield before elastic buckling and the Johnson parabola is used:

σcr = Sy − (Sy · Le / (2π r))² / E

For structural steel, the AISC 360 specification defines its own curve, and for an eccentric load the secant formula is used; the calculator offers all four methods.

Worked example

A solid round A36 steel bar (E = 200 GPa, Sy = 250 MPa), d = 50 mm, L = 2 m, pinned at both ends, with a 50 kN load.

  1. Section: A = π·50²/4 ≈ 1963.5 mm²; I = π·50⁴/64 ≈ 306,796 mm⁴; r = d/4 = 12.5 mm.
  2. Slenderness: K = 1, so Le = 2000 mm and Le/r = 2000/12.5 = 160.
  3. Transition: Cc = √(2π²·200,000/250) ≈ 125.7. Since 160 > 125.7, the column is long and Euler applies.
  4. Critical load: Pcr = π²·200,000 MPa·306,796 mm⁴ / (2000 mm)² ≈ 151,400 N = 151.4 kN. Critical stress: 151,400/1963.5 ≈ 77.1 MPa, well below the 250 MPa yield strength.
  5. Safety factor: 151.4/50 ≈ 3.03.
  6. If the column were fixed–free (K = 2), the critical load would be a quarter, about 37.8 kN, less than the applied load: it would buckle.

In the calculator, with these data and the "Euler + Johnson" method, you get the same slenderness, the same critical load and the same safety factor.

How to use the calculator

  1. Type the length L and the load P, and choose the section (solid round bar, tube, rectangle, box or I-shape) and the material.
  2. In "Supports per axis", choose the end conditions (fixed, pinned, guided or free) for the strong and weak axes, and add braces where something prevents sideways movement.
  3. Choose the method: Euler + Johnson, Euler only, AISC 360 or secant.
  4. Check each axis's buckled shape, the column curve, the table with K, Le/r and each method's loads, the step by step and the minimum section size.

Common mistakes

Further reading

R. G. Budynas and J. K. Nisbett, Shigley's Mechanical Engineering Design (McGraw-Hill); J. M. Gere and B. J. Goodno, Mechanics of Materials (Cengage); for structural steel, the ANSI/AISC 360 specification. Simuveliq is not affiliated with these authors, publishers or AISC.

More tools

Versión en español

© 2026 Simuveliq. All rights reserved.