Conduction is the heat that crosses a solid (or a fluid at rest) from hot to cold. This topic explains it as in class: Fourier's law and the heat equation, the thermal resistances of walls, pipes and spheres, contact resistance and the critical radius, internal generation, fins and transients (the Biot number, lumped capacitance, the exact series solution and the semi-infinite solid), and teaches how to solve each case in the heat transfer tool. At the end there are eleven worked examples that open in the simulator.

Heat, temperature and the three mechanisms

Heat is energy that passes from one body to another (or from one part of a body to another) only because their temperatures differ, and always from hot to cold. Thermodynamics says how much energy changes place between two states; heat transfer says at what rate: how many watts cross a wall, how long a part takes to cool down, what temperature a cable reaches. There are three mechanisms:

  • Conduction: inside a solid or a fluid at rest, by molecular collisions and the motion of the free electrons of metals. It follows Fourier's law and is the subject of this page.
  • Convection: between a surface and a fluid moving over it; it is summarized by Newton's law of cooling, , with a coefficient that depends on the flow.
  • Radiation: electromagnetic waves emitted by every surface because it is at some temperature, needing no medium; the Stefan–Boltzmann law, , gives the emission of a blackbody.

Convection, radiation and heat exchangers have a topic of their own; here they appear only as conditions on the faces of the solids. The quantities used, with the tool's symbol and unit:

QuantitySymbolSIUSThe tool's equivalence
Heat rateWBtu/h1 Btu/h = 0.29307 W
Heat flux (per area)W/m²Btu/(h·ft²)1 Btu/(h·ft²) = 3.1546 W/m²
Heat per length (pipes)W/mBtu/(h·ft)1 Btu/(h·ft) = 0.96152 W/m
Generation per volumeW/m³Btu/(h·ft³)1 Btu/(h·ft³) = 10.350 W/m³
Thermal conductivityW/(m·K)Btu/(h·ft·°F)1 Btu/(h·ft·°F) = 1.7307 W/(m·K)
Convection coefficientW/(m²·K)Btu/(h·ft²·°F)1 Btu/(h·ft²·°F) = 5.6783 W/(m²·K)
Resistance per aream²·K/Wh·ft²·°F/Btu1 h·ft²·°F/Btu = 0.17611 m²·K/W
Thermal diffusivitym²/sft²/h1 ft²/h = 2.5806×10⁻⁵ m²/s
A temperature difference is the same in kelvin as in degrees Celsius (1 K = 1 °C of difference), so in it makes no difference whether K or °C is used. Only radiation () needs absolute temperatures.

Fourier's law and the heat equation

Fourier's law says that the conduction heat flux is proportional to the temperature gradient and points the way the temperature falls:

The minus sign makes positive when decreases with . The conductivity is a property of the material: large in metals, which conduct with their free electrons, and small in gases and insulators, which trap air in pores or fibers. The tool carries no table of solids: the , the density and the specific heat of each solid are typed by you, with the data of your textbook or instructor. These are the values its examples use (they are the data of each exercise):

Material of the example (W/(m·K))Example of the tool
Copper3985 mm copper rod as an infinite fin
Aluminum205 y 237Straight aluminum fin; two metal plates
Cast iron80Steam pipe at 320 °C
Steel455 cm steel ball
Stainless steel15Two metal plates; thick cylinder in water
Glass0.78Double-pane window
Brick0.72Brick wall with insulation
Moist soil0.4Buried pipe
Gypsum, plastic, wood0.17, 0.15, 0.12Stud wall; 3 mm wire
Insulation and fiberglass0.05, 0.04, 0.038Steam pipe; brick wall; stud wall
Still air in a gap0.026Double-pane window

Where the heat equation comes from

Take a slice of the solid of thickness and area . The energy balance says: what enters by conduction, minus what leaves, plus what is generated inside (an electric current, a reaction) is what is stored:

qx qx+Δx generatesq̇ A Δxxx + Δxstores ρ c A Δx ∂T/∂t
The balance of a slice: enters, leaves, watts are generated and the difference heats the slice.

Dividing by and letting , , and with Fourier's law:

The thermal diffusivity measures how fast a solid evens out its temperatures: it conducts a lot () relative to what it stores (). For a cylinder or a sphere, with instead of , the equation is the same with an area that grows with the radius:

Each problem of this topic is a case of those equations with its boundary conditions: a given temperature on a face, a given flux (zero if the face is insulated) or convection with a fluid, at the face. The tool solves each case exactly: the plane wall, the cylinder and the sphere at steady state (without ), with or without generation, the fin, and the lumped, series and semi-infinite transients.

Plane wall and thermal resistance

At steady state, without generation and with constant , the equation reduces to : the temperature is a straight line between both faces. With and ,

It has the same form as Ohm's law: the temperature difference pushes the heat as the voltage pushes the current, and the wall opposes it with a thermal resistance. Convection at a face is written the same way, with . So a wall with a fluid on each side is a circuit of resistances in series:

Electric circuitThermal circuit
Voltage (V)Temperature (°C or K)
Current (A)Heat rate (W)
Resistance (Ω)Resistance (K/W)
Series: Layers one after another and the convection of each face
Parallel: Materials side by side within one layer

Working per unit area is the most convenient: in m²·K/W, for a layer and for convection. The face temperatures follow by subtracting, resistance by resistance, the drop from one end: it is the voltage-divider rule. In the wall of example 1 (200 mm of brick with = 0.72 and 50 mm of insulation with = 0.04, air at 20 °C with = 10 inside and at −10 °C with = 25 outside) the resistances per m² are 0.1, 0.2778, 1.25 and 0.04, which add up to 1.668 m²·K/W, and W/m² passes.

fluid 1brickinsulationfluid 2h1 = 10h2 = 25q″ = 17.99 W/m²20 °C18.2 °C13.2 °C−9.28 °C−10 °CR1 = 0.1R2 = 0.2778R3 = 1.25R4 = 0.04T∞,1 Ts,1 Ti Ts,2 T∞,2
Example 1: the temperature (red) is straight in each layer, steeper where is smaller, and bends in the boundary layers of both fluids. Below, the same problem as a circuit: to in m²·K/W. The insulation, with 75 % of the resistance, takes 75 % of the 30 °C.

Without the insulation the resistance falls to 0.4178 m²·K/W and the heat rises to 71.81 W/m², four times more: in a wall the layer that rules is the one with the largest . Note also that is small compared with the rest: with a strong wind (large ) the outer face is almost at the air temperature.

Layers in series and in parallel, and contact resistance

A wall with wood studs and fiberglass between them has two materials side by side within one layer: the heat has two paths and follows both at once. If each face of that layer is at a single temperature (what the tool assumes), each material is a resistance with its area fraction and both are in parallel:

In example 2 (90 mm with wood, = 0.12, over 15 % of the area and fiberglass, = 0.038, over 85 %), W/(m·K) and the layer is worth m²·K/W. Each branch on its own, per m² of wall, is worth and , and in parallel they give the same. With gypsum, sheathing and both convections, = 2.161 m²·K/W and = 12.03 W/m².

0.1250.0764752.7860.130.041/h1 gypsumwood 15 %fiberglass 85 %sheathing1/h2 T∞,1 T∞,2 q'' = 12.03 W/m², with each face of the layer at one temperatureboth branches in parallel: 1.789 m²·K/W
Example 2 as a circuit (m²·K/W per m² of wall): the wood, although it covers only 15 %, lets through more heat than its area would suggest (it is a «thermal bridge»). If the whole layer were fiberglass, would rise to 2.740 and the heat would drop to 9.489 W/m²: the studs increase the heat by 27 %.
The parallel model with isothermal faces is an approximation: it assumes the heat spreads sideways between both materials at the faces of the layer. The other extreme, paths insulated from each other running through the whole wall, gives a little less heat; the real value lies between both.

Contact resistance

Two surfaces that look flat touch only at the peaks of their roughness; between them there is air (or vacuum), which conducts far worse than the metal. That interface adds a resistance per area that is measured (it depends on the roughness, the clamping pressure and what fills the gaps: a thermal grease reduces it a lot). In the circuit it is one more resistance, between both layers:

In example 3, 10 mm of aluminum ( = 237) and 10 mm of stainless steel ( = 15) between 100 and 20 °C, with = 0.0002 m²·K/W: the aluminum is worth , the contact and the steel , in total m²·K/W, and 88 020 W/m² pass. The interface jumps from 96.29 to 78.68 °C: it takes 17.6 °C, 22 % of the difference, almost five times what the aluminum takes. Between metals the contact may dominate; between insulators it goes unnoticed.

Cylinders and spheres

In a pipe heat flows radially and crosses ever larger areas, . Without generation and at steady state, the same crosses every radius:

The profile is logarithmic: it falls quickly near the inner radius, where the area is small, and more slowly outward. In a sphere the area is and the integral of gives

The layers of an insulated pipe are in series like those of a wall, each with its own pair of radii. A long pipe is handled per meter ( = 1 m: in m·K/W and in W/m). In the steam pipe of example 4 (inner radius 25 mm, 2.5 mm of cast iron and 30 mm of insulation with = 0.05), the insulation gives m·K/W out of a total of 2.608, and 120.8 W/m pass; without insulation 736.3 W/m would pass.

2530354045505560050100150200250300350radius r (mm)T (°C)ABinsulationpipe
Example 4: in the cast-iron wall (black) the temperature barely changes; in the insulation (red) it falls from 307.2 °C at A, the inner surface, to 23.57 °C at B, the outer one, following a logarithm, below the straight line (dashed) a plane wall of the same thickness would give: it falls faster near the pipe, where the area is smaller.

The critical insulation radius

Adding insulation around a pipe does two things: the conduction resistance, , grows, but the outer surface also grows and the convection one, , falls. The sum has a minimum where its derivative vanishes:

If the outer radius is below , adding insulation increases the heat until , where the resistance is minimum; above it, insulation reduces it. In a steam pipe mm, far below its radius of 27.5 mm: insulation always helps. In a thin wire the opposite happens, and it is useful: the plastic cools it. A 3 mm wire with 2 mm of plastic ( = 0.15) in air with = 12 has mm; dissipating 80 W over 5 m, bare it would be at 171.5 °C, with the plastic it is at 105.0 °C, and with 11 mm of plastic (outer radius equal to ) it would drop to 82.97 °C (example 5).

1251020501000246810outer radius of the plastic (mm, log scale)R′ (m·K/W)ABCrcr = k/h = 12.5 mm
The resistance per meter of the wire of example 5 against the outer radius of the plastic: A, the bare wire (8.842 m·K/W); B, with 2 mm of plastic (4.688); C, the minimum at = 12.5 mm (3.311). Beyond the minimum the plastic insulates again, but very slowly.

Internal heat generation

A wire carrying current, a reactor's fuel or setting concrete produce heat inside: in W/m³. Now the heat crossing each section grows with the distance from the center, because it accumulates what was generated before, and the temperature is no longer straight. In a wall of thickness with both faces at , at steady state:

It is a parabola with its maximum at the center. In a solid cylinder or sphere of radius , the same reckoning with the radial equation gives the same shape, , with another maximum difference. And the surface temperature follows from a balance of the whole body: everything generated leaves by convection, :

Shape is
Wall, both faces cooledthe half-thickness2
Wall with one face insulatedthe thickness (the maximum, at the insulated face)2
Solid cylinderthe radius 4
Solid spherethe radius 6
00.20.40.60.8100.10.20.30.40.50.6x/L or r/r₀(T − Tₛ) / (q̇L²/k)wall: 1/2cylinder: 1/4sphere: 1/6
The temperature profile with generation, without dimensions: the same parabola, half as high in the cylinder and a third as high in the sphere as in the wall, because their surface is larger for the same volume.

A heating element 4 mm in diameter dissipating 2 kW over 0.5 m generates W/m³; with = 15 and the surface at 105 °C, the center is °C hotter: 126.2 °C (example 6). The wall with two different face temperatures has its maximum shifted toward the hotter face, at (if it falls outside the wall, the maximum temperature is that of the hotter face).

Fins

When the air side is the limiting one (a small ), the way to remove more heat is to provide more surface: fins are added, thin pieces of metal that conduct the heat from the base along their axis while giving it up by convection through their perimeter. For a fin of constant cross-section and perimeter , the balance of a piece is

The general solution is ; at the base , and at the tip there are four possible conditions, the tool's four. The fin heat is the one entering through the base, at , and all are written with :

TipCondition
A: convection
B: adiabatic
C: given temperature
D: infinite
00.20.40.60.8100.20.40.60.81x / Lθ / θb DCBAtip
The four tips with = 1.5: A, convection with = 0.5; B, adiabatic; C, the tip at = 0.6; D, the infinite fin (dashed). With , A would give exactly curve D. At the same the fin with a convective tip ends colder at the tip than the adiabatic one because it also loses heat through it. In C the tip is hotter than the adiabatic one would be (0.4251): the rod also receives heat at that end and the temperature has a minimum inside.

Case C is a rod between two walls at known temperatures; if does not lie between and , the tool warns: the tip receives heat from another source. The formulas with and overflow for large ; the tool evaluates them factoring out , so it gives finite numbers with any length.

Corrected length and the «infinite» fin

The convective tip is approximated very well as adiabatic if the fin is lengthened so that the tip face becomes perimeter: for a rectangular fin of thickness and for a pin fin. And since , a fin with already gives 99 % of the infinite fin's heat: beyond lengthening it is useless. The 5 mm copper rod with = 100 has = 14.18 m⁻¹: beyond 186.9 mm it is «infinite» and dissipates = 8.31 W with the base at 100 °C in air at 25 °C.

Efficiency, effectiveness and fin resistance

Two numbers tell whether a fin is well chosen:

The efficiency compares its heat with that of an ideal fin of infinite conductivity, all at ; with an adiabatic tip it is , which drops as the fin is lengthened: the metal at the end is almost at the air temperature and does little work. The effectiveness compares with what would leave through the base without the fin; a fin is justified if it exceeds 2, and the tool warns below that. And the fin's Biot number, , must be small (≤ 0.1) for the temperature to be uniform over each section, as the model assumes.

00.511.522.533.5400.20.40.60.81mL (or m·Lc )efficiency and fraction of the heatq/q∞ = tanh mLη = tanh(mL)/mL2.65A
With an adiabatic tip, the efficiency (blue) drops as grows and the fraction of the infinite fin's heat, (red), approaches 1: beyond 2.65 it exceeds 99 %. A is the aluminum fin of example 7, with = 0.3668 and ≈ 0.9574.

Fin arrays

A heat sink has fins on a base of area ; between them is the free base, , which works with efficiency 1. The whole is handled with an overall efficiency:

With 20 aluminum fins of 1.5 mm × 100 mm × 30 mm on 0.1 × 0.1 m (example 8) the area goes from 0.01 to 0.1288 m², = 0.9476 and the heat from 16.5 W without fins to 201.4 W: 12.2 times more.

Transient conduction: the Biot number

A part taken out of the oven and cooling in air has no fixed profile: its temperature changes with time and, in general, from point to point too. The first thing is to know whether that internal difference matters. The heat must travel from inside to the surface (conduction resistance ) and leave to the fluid (convection resistance ). Their ratio is the Biot number:

With a small Bi internal conduction is much easier than escaping to the fluid and the part is practically at a single temperature; with a large Bi the surface cools at once and the center lags. The characteristic length is the volume over the surface: for a sphere, for a long cylinder, the half-thickness for a plate cooled on both faces and for a cube. The Fourier number is dimensionless time: how many times the heat has had time to cross the part.

−1−0.500.511.500.20.40.60.81x/L (the plate spans −1 to 1; the fluid is on the right)θ / θᵢBi = 0.1Bi = 1Bi = 10fluid
A plate cooling from both faces, when its center has fallen to = 0.6 (exact solution). With Bi = 0.1 it is almost flat (the face is at 0.5712); with Bi = 1 the face falls to 0.3913, and with Bi = 10 to 0.08512: the jump is inside the solid, not in the fluid.

Lumped capacitance

If Bi ≤ 0.1 (the tool checks it: the error is below about 5 %), the part has a single temperature at each instant. The heat it loses by convection is what lowers its internal energy:

The time constant is how long it takes to cover 63.2 % of the way (). Solving for it, the time to reach is , and the heat given up by then is . A thermocouple is the typical case: its 0.7 mm junction with = 400 has = 0.9917 s and takes = 4.567 s to read 99 % of a temperature step. The same reckoning backward measures : one records how long a copper sphere takes to cool and solves for it.

The exact series solution

With Bi > 0.1 the full heat equation must be solved. For a plate, a long cylinder and a sphere in a fluid, separation of variables gives a sum of terms that decay with time:

ShapeRoots of
Plate ()
Cylinder ()
Sphere ()
Watch the length: in the series, Bi and Fo use the half-thickness or the radius , not . For the same cylinder, the lumped Bi is half the series one (). The tool gives both and says so in the step by step.

Each term decays as and the grow quickly, so after a little time (Fo > 0.2) the first one is enough: at the center. The tool adds as many terms as needed (those still weighing more than ) with the roots found by bisection and the exact Bessel functions, and gives the center, the surface and the fraction of the energy given up, . In the thick cylinder of example 10 the lumped model would say 49.85 °C after 600 s; the series gives 100.3 °C at the center and 65.62 °C at the surface.

0200400600800100012000100200300400500t (s)T (°C)━━ lumped╍╍ exact, center━━ exact, surfacet = 600 s
Example 10, a 100 mm stainless-steel cylinder (Bi = 0.8333 with , 1.667 with ) in water: the lumped model (blue) runs far ahead of the real center (red, dashed); the surface (green) falls at once.

Semi-infinite solid

The ground under a frost, a thick slab exposed to fire or the hand touching a part: at first the heat has only entered a little way and the solid behaves as if it had no bottom. The temperature depends on and only through the similarity variable , and with the surface suddenly brought to the solution is the error function:

Since , heat has only reached appreciably down to , the penetration depth; the model holds while the real solid is thicker. And since the depth grows with , going twice as deep takes four times as long. The tool has the four surface conditions:

SurfaceSolution
Temperature
Flux
Convection (, )
Contact with another solid with , then the row

The contact condition explains why steel «feels» colder than wood at the same temperature: the contact surface stays at the mean of both initial temperatures weighted by the effusivities . The hand ( = 0.6, = 1000, = 3600, = 1470) on steel at 10 °C ( = 12 707) sits in contact at 12.80 °C: the steel imposes its temperature. A material of small effusivity would leave the contact near 37 °C. In the ground of example 11, with the surface at −10 °C for 90 days, 0 °C reaches 0.801 m deep.

00.511.522.533.54−10−5051015depth x (m)T (°C)A━━ 10 days━━ 30 days━━ 90 days
Example 11: the ground ( m²/s, initially at 15 °C) with its surface at −10 °C. After 90 days 0 °C (dashed) is at A, 0.801 m deep; the penetration, , is 3.888 m.

Using the simulator

It is in Engineering → Thermodynamics and fluids → Heat transfer. On the left is the «Heat transfer» panel with the question «What do you want to compute?» and six views; on the right, the result cards, the warnings, the figures and the «Step by step», recomputed with every keystroke. This topic uses three views: «Conduction», «Fins» and «Transient» (the other three, «Convection», «Heat exchangers» and «Radiation», belong to the convection and radiation topic).

  • Case: below the view choose the case: in «Conduction», «Plane wall», «Cylinder», «Sphere» or «Internal generation»; in «Transient», «Lumped capacitance» or «Semi-infinite solid». «Fins» has just one.
  • Examples: the dropdown («Choose…») brings the examples of each view; the eleven examples of this topic come from that list.
  • Free data: in almost every case you type what you have and leave empty what you are looking for. Without the heat, everything else must be typed and the heat is computed; with the heat typed, leave a thickness, a k, an h or a temperature empty and it is solved for. If there are too many or too few, the tool says so («Missing data: leave empty only what you are looking for…»).
  • Units: the «SI» and «US» buttons in the header convert every field (layer lengths, diameters and thicknesses go in mm or in; temperatures in °C or °F). Going back to the previous system restores exactly what was typed.

Conduction

CaseWhat you typeWhat it gives
«Plane wall»In «Wall sides», «Side 1» and «Side 2», each «Fluid (h, T∞)» or «Surface temperature»; «Area A (empty = per m²)»; in «Layers, from side 1 to 2», each layer with its name, L, k and R″c (the contact resistance with the next one), «+ Layer» and «×»; the «Materials side by side (in parallel)» box opens the materials with their «Area %» and «+ Material».«Heat flux q″», «Total resistance», «Surface 1» and «Surface 2»; the figure with the profile and the resistance network.
«Cylinder» and «Sphere»«Inner radius r₁», «Length L (empty = per meter)», «Inside» and «Outside», and the «Layers, from inside out» with their thickness t.«Heat per meter» or «Heat», «Inner surface», «Outer surface» and «Critical radius» (if there is convection outside), with the curve of the heat against the outer radius. When solving for a thickness there can be two solutions, one on each side of the critical radius.
«Internal generation»In «Geometry», the «Shape» («Wall, both faces cooled», «Wall with one face insulated», «Solid cylinder», «Solid sphere» or «Wall with two face temperatures»), «Generation q̇», «Conductivity k» and the size; in «Surface», «Fluid (h, T∞)» or «Given temperature», and «Maximum temperature».Without the maximum temperature, it computes it with the profile; with it typed, leave another value empty (q̇, k, the size, h or a temperature) and it solves for it.

Fins

In «Fin», «Straight rectangular» (with «Thickness t» and «Width w») or «Pin» (with «Diameter D»), the «Length L» and the «Conductivity k». In «Base, fluid and tip», «Base T_b», «Fluid T∞», «Coefficient h» and the «Tip»: «Convection (A)», «Adiabatic (B)», «Given temperature (C)» (with «Tip T_L») or «Infinite (D)», the four of the table above with the same letters. The «Several fins on a base (overall efficiency)» box of «Fin array» asks for the «Number of fins N» and the «Base area». The cards: «Fin heat», «Efficiency», «Effectiveness», «m · L», «Tip temperature» and, with the array, «Array heat» and «Gain over no fins». The step by step also gives the corrected length and the fin Biot number; the «The fin» figure shows T(x) and the sketch.

Transient

«Lumped capacitance»: in «Body», the «Shape» («Sphere», «Long cylinder», «Plate (two faces)», «Cube» or «Other (V and Aₛ)»), its size, «Density ρ», «Specific heat c» and «Conductivity k»; in «Fluid and time», «Initial Tᵢ», «Fluid T∞», «Coefficient h», the «Time unit» (s, min, h or days), «Time t» and «Temperature T»: leave one of h, t or T empty. It gives «Bi» (with the warning if it exceeds 0.1), «Time constant», the time or the temperature, «Heat given up by the body» and, for sphere, cylinder and plate, «Exact: center» (with the surface) and «Exact: time (center)».

«Semi-infinite solid»: in «Solid», «Conductivity k», «Initial Tᵢ» and «Density ρ» with «Specific heat c», or the «Diffusivity α» directly; in «Surface condition», «Temperature», «Flux», «Convection» or «Contact» (with «k of the other solid», «ρ of the other solid», «c of the other solid» and «Initial T of the other solid»); in «Point and time», «Depth x», «Time t» and «Temperature T»: leave one empty. It gives the «Depth», the «Time» or the «Temperature», «η», the «Surface», the «Surface flux» and the «Penetration».

In every case, «Step by step» has each formula with the problem's numbers, and the «Detailed solution (PDF)» button opens the complete solution to print or save, with the statement, the idea, the steps and the figures. The «Report» button in the header saves the page's results.

Common mistakes

  • Mixing areas: adding (m²·K/W) to (K/W). All per m², or all with their area.
  • Typing the layers in meters where the tool asks for mm (or the other way round): 200 mm of brick typed as 0.2 is a 0.2 mm sheet, a thousand times thinner. The unit is next to each field.
  • Using for a pipe: the resistance of a cylinder is ; with thin layers it is almost the same, with thick insulation it is not.
  • Believing that more insulation always reduces the heat: below the critical radius ( for a cylinder) it increases it.
  • Forgetting that with generation the maximum is inside: the temperature that limits the material is the center's, not the surface's.
  • Using the perimeter instead of for a rectangular fin: the tool uses the exact one and says so; with the difference is small.
  • Choosing a fin only by its efficiency: a very short fin is almost 100 % efficient but dissipates little; what matters is the heat and the effectiveness (above 2).
  • Applying lumped capacitance without computing Bi, or computing Bi with the radius instead of ; and, conversely, using in the series solution, which goes with the half-thickness or the radius.
  • Using the semi-infinite solid when the heat has already reached the other side: compare the real thickness with .

Worked examples

Each example opens in the tool with its button; the material data are those of the exercise.

Example 1Brick wall with insulation

A 10 m² wall has 200 mm of brick ( = 0.72 W/(m·K)) and 50 mm of insulation ( = 0.04). Inside there is air at 20 °C with = 10 W/(m²·K) and outside at −10 °C with = 25. Find the heat flux, the total heat, the temperatures of the faces and of the joint, and the overall coefficient .

Solution

  1. Resistances per m²: , , and m²·K/W; in series, m²·K/W.
  2. W/m² and W. W/(m²·K).
  3. Temperatures, subtracting from inside (with ): inner face °C; joint °C; outer face °C, and °C, the air: the reckoning closes.
= 17.99 W/m², = 179.9 W, faces at 18.20 °C and −9.28 °C, joint at 13.20 °C, = 0.5996 W/(m²·K). Without insulation 71.81 W/m² would pass.

Solve it in Simuveliq

  1. In «What do you want to compute?» press «Conduction» and in «Examples» choose Brick wall with insulation: air at 20 °C inside and −10 °C outside.
  2. The cards give «Heat flux q″» 17.99 W/m² (q = 179.9 W), «Total resistance» 1.668 m²·K/W, «Surface 1» 18.2 °C and «Surface 2» −9.28 °C; the «Profile and resistance network» figure is the one in this topic.
  3. Remove the insulation with its «×»: the flux rises to 71.81 W/m².

Example 2A stud wall: a parallel layer

A wall has 13 mm of gypsum ( = 0.17), a 90 mm layer with wood studs ( = 0.12) over 15 % of the area and fiberglass ( = 0.038) over 85 %, and 13 mm of sheathing ( = 0.1). Inside, air at 21 °C with = 8; outside, at −5 °C with = 25. Find the heat flux per m² and compare it with the same wall without studs.

Solution

  1. The parallel layer: W/(m·K), so m²·K/W.
  2. The rest: , gypsum , sheathing and . Total m²·K/W and W/m²; = 0.4628 W/(m²·K).
  3. Without studs, the layer is worth , and W/m²: the studs, covering 15 % of the area, increase the heat by 27 %.
= 12.03 W/m² ( = 2.161 m²·K/W), against 9.489 W/m² without studs.

Solve it in Simuveliq

  1. «Examples» → Wall with wood studs and fiberglass (parallel layer). The middle layer has «Materials side by side (in parallel)» checked, with wood at 15 % and fiberglass at 85 % in «Area %».
  2. Cards: «Heat flux q″» 12.03 W/m² and «Total resistance» 2.161 m²·K/W (U = 0.4628). The step by step gives = 0.0503.
  3. Uncheck the box and type k = 0.038 in that layer: the flux drops to 9.489 W/m².

Example 3Contact resistance between two plates

A 10 mm aluminum plate ( = 237) is pressed against a 10 mm stainless-steel plate ( = 15), with a contact resistance of 0.0002 m²·K/W. The outer faces are at 100 °C and 20 °C. Find the heat flux and the temperature jump at the contact.

Solution

  1. Resistances: aluminum , contact and steel m²·K/W; total .
  2. W/m². The aluminum face at the contact is at °C and the steel one at °C.
  3. The contact takes 17.6 °C, 22 % of the 80 °C.
= 88 020 W/m²; the contact jumps from 96.29 to 78.68 °C (17.6 °C).

Solve it in Simuveliq

  1. «Examples» → Two metal plates with contact resistance. Both sides are «Surface temperature» and the first layer has R″c = 0.0002.
  2. «Heat flux q″» gives 88020 W/m²; the step by step and the figure give the temperature of each node, 96.29 °C and 78.68 °C at the contact.
  3. Clear R″c (perfect contact): the flux rises to 112 900 W/m².

Example 4Insulated steam pipe

A cast-iron pipe ( = 80) with a 50 mm inner diameter and a 2.5 mm wall carries steam at 320 °C ( = 60 W/(m²·K)) and has 30 mm of insulation ( = 0.05). Outside, air at 5 °C with = 18. Find the heat lost per meter, the surface temperatures and the critical radius.

Solution

  1. Radii: 25, 27.5 and 57.5 mm. Per meter: , , and m·K/W.
  2. m·K/W and W/m.
  3. Inner surface: °C; outer: °C.
  4. mm, far below 27.5 mm: any insulation reduces the heat.
= 120.8 W/m (736.3 W/m without insulation); surfaces at 307.2 °C and 23.57 °C; = 2.778 mm.

Solve it in Simuveliq

  1. «Conduction» → «Cylinder» → «Examples» → Steam pipe at 320 °C with 3 cm of insulation (per meter). «Length L (empty = per meter)» stays empty.
  2. Cards: «Heat per meter» 120.8 W/m, «Total resistance» 2.608 m·K/W, «Inner surface» 307.2 °C, «Outer surface» 23.57 °C and «Critical radius» 2.778 mm.
  3. Remove the insulation with its «×»: 736.3 W/m.

Example 5A wire that cools better with plastic

A wire 3 mm in diameter and 5 m long dissipates 80 W. It has 2 mm of plastic ( = 0.15) and is in air at 30 °C with = 12. At what temperature is the wire under the plastic? And bare, or with the plastic thickness that gives the critical radius?

Solution

  1. With = 5 m: K/W and K/W; total 0.9377 K/W.
  2. °C, with the plastic surface at °C.
  3. mm > 3.5 mm: the plastic still helps. Bare, K/W and the wire would be at 171.5 °C; with 11 mm of plastic (outer radius 12.5 mm) the resistance is the minimum, 0.6621 K/W, and it would drop to 82.97 °C.
105.0 °C with 2 mm of plastic; 171.5 °C bare and 82.97 °C with the critical radius (12.5 mm).

Solve it in Simuveliq

  1. «Conduction» → «Cylinder» → «Examples» → 3 mm wire dissipating 80 W: temperature under the plastic. «Inside» is «Surface temperature» with Tₛᵢ empty, and the heat q = 80 W is typed: the temperature is solved for.
  2. Cards: «Inside temperature» 105 °C, «Outer surface» 90.63 °C and «Critical radius» 12.5 mm, larger than the plastic's outer radius (3.5 mm).
  3. Change the plastic thickness t to 11: the temperature drops to 82.97 °C; with 50 it rises again to 94.15 °C.

Example 6The center of an electric heater wire

A heater wire 4 mm in diameter and 0.5 m long dissipates 2 kW uniformly. Its is 15 W/(m·K) and its surface is at 105 °C. Find the generation per volume and the temperature at the center.

Solution

  1. W/m³.
  2. Solid cylinder ( = 4): °C, so °C.
  3. Check: through the surface goes W/m², and per meter W/m: the 2 kW of 0.5 m.
= 3.183 × 10⁸ W/m³; center at 126.2 °C, 21.22 °C above the surface.

Solve it in Simuveliq

  1. «Conduction» → «Internal generation» → «Examples» → 4 mm heater wire: center temperature (2 kW in 0.5 m). The «Shape» is «Solid cylinder» and the surface «Given temperature».
  2. The «Maximum temperature» card gives 126.2 °C.
  3. Type 120 in «Maximum temperature» and clear «Generation q̇»: the generation that leaves the center at 120 °C is solved for, 2.25 × 10⁸ W/m³.

Example 7A straight aluminum fin

A straight aluminum fin ( = 205), 2 mm thick, 100 mm wide and 25 mm long, has its base at 120 °C in air at 25 °C with = 40 W/(m²·K), at the tip too. Find the heat, the efficiency, the effectiveness and the tip temperature.

Solution

  1. m², m, m⁻¹ and .
  2. W and . Tip A: W.
  3. m²: ; . The tip: °C.
  4. With the corrected length mm and an adiabatic tip: and W, almost the same.
= 19.28 W, = 95.75 %, = 25.37, tip at 114.0 °C.

Solve it in Simuveliq

  1. Press «Fins» and in «Examples» choose Straight aluminum fin with a convective tip: «Straight rectangular» with the tip «Convection (A)».
  2. Cards: «Fin heat» 19.28 W, «Efficiency» 95.75 %, «Effectiveness» 25.37, «m · L» 0.3527 and «Tip temperature» 114 °C.
  3. Try the other tips: «Adiabatic (B)» gives 18.61 W and «Infinite (D)» 54.95 W, the heat of a very long fin.

Example 8A twenty-fin heat sink

An aluminum heat sink ( = 205) has 20 fins of 1.5 mm × 100 mm × 30 mm on a 0.1 × 0.1 m base at 80 °C, in air at 25 °C with = 30. Take the tip as adiabatic. Find the heat of the heat sink and how much it improves on the base without fins.

Solution

  1. Each fin: m², m, m⁻¹, , and W.
  2. Areas: m², free base m² and m².
  3. and W. Without fins: W.
201.4 W with = 94.76 %, 12.2 times the 16.5 W of the bare base.

Solve it in Simuveliq

  1. «Fins» → «Examples» → Heat sink of 20 aluminum fins on 0.1 × 0.1 m: «Several fins on a base (overall efficiency)» is checked with «Number of fins N» = 20 and «Base area» = 0.01.
  2. Cards: «Fin heat» 9.491 W, «Efficiency» 94.45 %, «Array heat» 201.4 W (η_o = 94.76 %) and «Gain over no fins» × 12.2.
  3. Change N to 30: the heat rises to 293.8 W (in practice, closer fins slow the air down and lower ; the tool takes the typed).

Example 9A cooling steel ball

A 50 mm steel ball ( = 7800 kg/m³, = 460 J/(kg·K), = 45) comes out of an oven at 300 °C and cools in air at 25 °C with = 25. How long does it take to reach 100 °C and how much heat has it given up?

Solution

  1. mm and : far below 0.1, the ball is at a single temperature.
  2. s.
  3. s, about 25.9 min.
  4. , with m³: J and J, 72.73 %. The exact series gives 1563 s for the center: almost the same.
1554 s (25.9 min) and 46 970 J; Bi = 0.00463.

Solve it in Simuveliq

  1. Press «Transient» («Lumped capacitance») and in «Examples» choose 5 cm steel ball cooling in air from 300 to 100 °C. «Time t» is empty and «Temperature T» = 100.
  2. Cards: «Bi» 0.00463, «Time constant» 1196 s, «Time» 1554 s (25.9 min), «Heat given up by the body» 46970 J and «Exact: time (center)» 1563 s.
  3. Change the «Time unit» to min and type t = 60 with T empty: after an hour the ball is at 38.55 °C.

Example 10When Bi is large: the exact solution

A long 100 mm stainless-steel cylinder ( = 7900, = 480, = 15) at 500 °C is plunged into water at 30 °C with = 500. What is its temperature after 600 s? Compare lumped capacitance with the exact solution.

Solution

  1. mm and : the lumped model does not hold. It would still give s and °C.
  2. The series uses the radius: , m²/s and .
  3. The first root of is and . With Fo > 0.2 one term is enough: , and the center is at °C. The surface, with the whole series, at 65.62 °C; it has given up 88.91 % of its energy.
Center at 100.3 °C and surface at 65.62 °C; lumped capacitance would say 49.85 °C, far off.

Solve it in Simuveliq

  1. «Transient» → «Examples» → Thick cylinder in water: large Bi and the exact solution. The warning «Bi = 0.8333 > 0.1: the lumped model does not hold» appears.
  2. Cards: «Bi» 0.8333, «Time constant» 189.6 s, «Temperature» 49.85 °C (the lumped one) and «Exact: center» 100.3 °C (surface 65.62 °C). The step by step gives ζ₁ and C₁.
  3. Lower h to 50 (air with a strong fan): Bi drops to 0.08333 and both solutions come close, 372.5 °C the lumped one and 391 °C the center.

Example 11How deep does it not freeze?

The ground ( = 0.4 W/(m·K), = 1.5 × 10⁻⁷ m²/s) is at 15 °C when its surface drops to −10 °C and stays there for 90 days. How deep must a pipe be buried so that it does not fall below 0 °C?

Solution

  1. Semi-infinite solid with the surface at : , so .
  2. = 90 days = 7 776 000 s and m: m.
  3. The penetration, m, says the model holds if the ground is deeper than that. At the surface W/m² leaves (the ground loses heat).
At 0.801 m or deeper (η = 0.3708).

Solve it in Simuveliq

  1. «Transient» → «Semi-infinite solid» → «Examples» → How deep to bury a pipe so it does not freeze in 90 days at −10 °C?. «Depth x» is empty, the «Time unit» in days and «Time t» = 90.
  2. Cards: «Depth» 800.9 mm, «η» 0.3708, «Surface flux» −5.224 W/m² and «Penetration» 3888 mm.
  3. Type 30 in «Time t»: with a month of frost 462.4 mm is enough.