Heat transfer calculator: conduction, convection, radiation and heat exchangers

Choose what you want to compute —conduction, fins, convection, heat exchangers, radiation or transient conduction—, type the data of your problem and get the result with every formula substituted, the figures and a detailed PDF solution. Where it makes sense, the data are free: type what you have and leave empty what you are looking for (an insulation thickness, the length of a tube, the temperature of a surface, the area of an exchanger). In SI or English units.

Theory and worked examples: Conduction, fins and transients · Convection, radiation and heat exchangers.

What you can do

Frequently asked questions

How is the heat through a composite wall computed?

As a circuit: each layer is a resistance L/(kA), each fluid film 1/(hA) and each contact R″c/A; in series they add up and the heat is the total temperature difference divided by the total resistance, q = ΔT/R_total.

When does the lumped capacitance model hold?

When the Biot number, Bi = h·L_c/k with L_c = V/A_s, is below 0.1: the temperature inside the body is nearly uniform and T(t) = T∞ + (T_i − T∞)·exp(−t/τ), with τ = ρcV/(hA_s).

What is the difference between the LMTD and the ε-NTU methods?

Both solve the same exchanger. The LMTD (q = U·A·F·ΔT_lm) is direct when the four temperatures are known and the area is sought; ε-NTU is direct when the area is known and the outlet temperatures are sought.

Guide: heat transfer by conduction, convection and radiation

Heat flows from a hot place to a cold one in three ways: by conduction inside solids (and fluids at rest), by convection between a surface and a moving fluid, and by radiation between surfaces that see each other. This guide summarizes the ideas and formulas the tool uses in each view, works a complete example with the tool's numbers and points out the most frequent mistakes.

Conduction and thermal resistances

At steady state with no generation, the same heat crosses every layer of a wall. Fourier's law gives, for a plane layer of thickness L and conductivity k, q = kA·ΔT/L: the layer behaves as a resistance R = L/(kA). A fluid film with coefficient h is another resistance, 1/(hA), and an imperfect contact between two layers, R″c/A. In series they add up, as in an electric circuit:

q = (T∞,1 − T∞,2) / ΣR

If a layer has several materials side by side (wood studs and fiberglass, for example) and their faces are at one temperature, they are resistances in parallel. In a pipe or a sphere the area grows with the radius: the resistance of a cylindrical layer is ln(r2/r1)/(2πkL) and that of a spherical one (1/r1 − 1/r2)/(4πk). That is why a critical radius of insulation exists, rcr = k/h for a cylinder and 2k/h for a sphere: below it, adding insulation increases the heat lost. With internal generation q̇ the temperature is a parabola and the center is the hottest point: Tmax − Ts = q̇L²/(2k) in a wall, q̇r0²/(4k) in a cylinder and q̇r0²/(6k) in a sphere.

Fins

A fin conducts heat along its axis and gives it up through its surface. With m = √(hP/(kAc)) and M = √(hPkAc)·θb, the heat is M·tanh(mL) if the tip is adiabatic, M if the fin is very long (mL > 2.65), and somewhat longer formulas with convection or a given temperature at the tip. The efficiency compares the heat with that of an ideal fin entirely at the base temperature; the effectiveness, with that of the bare base: a fin is only worth it if its effectiveness exceeds 2. In an array, the overall efficiency weighs the fins and the free base.

Convection

The coefficient h comes from a dimensionless correlation, Nu = hL/k = f(Re, Pr), specific to each geometry and regime. Over a flat plate the boundary layer is laminar up to Rex ≈ 5 × 10⁵; for a cylinder in cross flow the tool uses the Churchill and Bernstein correlation; for a sphere, Whitaker's; in a tube, 3.66 or 4.36 in fully developed laminar flow and Gnielinski or Dittus–Boelter in turbulent flow. In natural convection the Rayleigh number, Ra = gβΔTL³/(να), takes the place of the Reynolds number. The properties are taken at the temperature each correlation asks for: the film temperature (Ts + T∞)/2 in external flow, the bulk mean in a tube. Outside a correlation's range of validity, the tool warns.

Heat exchangers

Three equations govern a heat exchanger: the energy balances of both streams, q = Ch(Th,i − Th,o) = Cc(Tc,o − Tc,i), and the rate equation, written either as q = U·A·F·ΔTlm (LMTD method) or as q = ε·Cmin(Th,i − Tc,i), with the effectiveness ε a function of the number of transfer units NTU = UA/Cmin and of Cr = Cmin/Cmax (ε-NTU method). The first is direct for sizing (the four temperatures known, the area unknown) and the second for rating an existing exchanger (the outlets unknown). The tool solves both forms and checks that they agree.

Radiation

A blackbody emits Eb = σT⁴, with the peak of its spectrum at λmaxT = 2897.8 μm·K (Wien). Between gray, diffuse surfaces the exchange is solved with a network of surface resistances, (1 − ε)/(εA), and space resistances, 1/(AiFij), between the powers σT⁴; a low-emissivity shield adds large resistances. The view factor Fij depends only on the geometry, and reciprocity (AiFij = AjFji) and the summation rule complete the enclosure.

Transient conduction

If the Biot number, Bi = hLc/k with Lc = V/As, is below 0.1, the body has almost the same temperature everywhere at each instant and T − T∞ falls as e−t/τ with τ = ρcLc/h (lumped capacitance). If not, the tool warns and gives the exact series solution for a plate, a long cylinder and a sphere. A thick solid heated through one face is treated as semi-infinite: with the surface at Ts, (T − Ts)/(Ti − Ts) = erf(x/(2√(αt))).

Worked example: brick wall with insulation

A 10 m² wall has 200 mm of brick (k = 0.72 W/(m·K)) and 50 mm of insulation (k = 0.04 W/(m·K)), with air at 20 °C inside (h = 10 W/(m²·K)) and at −10 °C outside (h = 25 W/(m²·K)) (problem data). It is the example the tool opens with.

  1. Resistances per m²: 1/10 = 0.1, 0.2/0.72 = 0.2778, 0.05/0.04 = 1.25 and 1/25 = 0.04 m²·K/W; in total, R″ = 1.668 m²·K/W.
  2. Heat flux: q″ = (20 − (−10))/1.668 = 17.99 W/m², and through the whole wall q = 179.9 W.
  3. Temperatures: subtracting q″·R″ across each resistance, the inner face is at 18.2 °C, the brick–insulation interface at 13.2 °C and the outer face at −9.28 °C. Almost all the drop happens in the insulation, which has the largest resistance.

With the example «What insulation thickness lets only 15 W/m² through?» the tool solves for that thickness: 63.29 mm. And with the counterflow exchanger of the example «Oil–water counterflow» (oil at 150 °C, 0.5 kg/s and cp = 2131 J/(kg·K); water at 20 °C and 0.6 kg/s; U = 300 W/(m²·K) and A = 5 m²) it gives NTU = 1.408, ε = 0.6844, q = 94.8 kW and the outlets at 61.03 °C and 57.8 °C.

How to use the tool

  1. In «What do you want to compute?» choose the view and, below it, the case (plane wall, cylinder, plate, tube, blackbody…).
  2. Type the data. Where the tool mentions free data, leave empty what you are looking for: for example, type the heat and leave a thickness, a conductivity, a temperature or an exchanger's area empty.
  3. In convection and heat exchangers choose the fluid: air, water and others take their properties from the site's thermodynamic tables; for an oil, choose «Other fluid» and type its properties.
  4. Read the cards, the warnings, the figures and the step by step; the «Detailed solution (PDF)» has the statement, every step explained and the summary.

Common mistakes

Further reading

The conduction, convection, heat exchanger and radiation chapters of any engineering heat transfer textbook. The correlations carry their authors' names (Churchill and Bernstein, Whitaker, Gnielinski, Dittus and Boelter, Churchill and Chu, Hausen) and the ε-NTU relations and view factors are computed with their formulas. The properties of air, water and the other fluids come from the reference equations of state and the viscosity and conductivity models implemented in CoolProp 8.0.0 (I. H. Bell and coworkers, MIT license), as in the site's thermodynamic tables. Simuveliq is not affiliated with the CoolProp project.