Convection, radiation and heat exchangers
Convection, radiation and heat exchangers are the other faces of heat transfer. This topic explains the boundary layer and the dimensionless numbers, the correlations the tool uses (plate, cylinder, sphere, tubes and natural convection) with their range of validity, the black and the gray body with the laws of Planck, Wien and Stefan–Boltzmann, view factors and radiation shields, and heat exchangers by LMTD and ε-NTU, to rate or to size them. Twelve worked examples open in the simulator.
Convection: Newton's law and the coefficient h
When a fluid moves over a surface at another temperature, heat passes from one to the other by conduction in the layer of fluid next to the wall and is carried away by the motion. All of that is summed up by Newton's law of cooling:
The law is almost a definition: the hard part is , which is not a property of the fluid. It depends on the fluid (its properties at the right temperature), the velocity, the geometry, the size and whether the flow is laminar or turbulent, forced or natural. To compute it one uses correlations: equations fitted to experiments, each with its range of validity. To get a feel, these are the the tool gives in its own examples:
| Case (example of the tool) | (W/(m²·K)) |
|---|---|
| Still air, 0.5 m vertical plate at 75 °C | 5.261 |
| Still air, 100 mm horizontal pipe at 150 °C | 7.19 |
| Air at 5 m/s over a 0.5 m plate | 12.38 |
| Air at 20 m/s over a 2 m plate | 45.08 |
| Air at 10 m/s around a 25 mm tube | 72.19 |
| Hot air in a 50 mm duct | 86.19 |
| Still water, 30 mm sphere at 60 °C | 923.7 |
| Water inside a 25 mm tube, turbulent | 1351 |
| Water at 1 m/s over a 0.3 m plate | 1531 |
| Water at 0.5 m/s around a 12 mm cylinder | 5162 |
Three rules come out of the table: water gives coefficients a hundred times larger than air (it conducts more and has more capacity); forced convection beats natural convection; and small objects have a larger than large ones, because their boundary layer is thinner.
The boundary layer
Over a plate, the fluid touching the wall is at rest (no slip) and the velocity grows to that of the free stream, , over a thickness : the velocity boundary layer. Likewise, the temperature goes from to in the thermal boundary layer, of thickness . Since the fluid does not move at the wall, heat crosses it by conduction, and that gives the shape of :
A thin boundary layer gives a large . The layer starts thin at the leading edge and thickens downstream; while it is laminar, the layers of fluid slide in order; beyond a critical Reynolds number, on a smooth plate (the tool's default, which can be changed), eddies appear that mix the fluid and the layer becomes turbulent: thicker, but with a much fuller profile next to the wall and a much larger .
In the laminar region the boundary-layer solutions give the thickness and the local coefficient:
Since goes as , the mean coefficient of a laminar plate is twice the local one at the end. In example 1 (air at 5 m/s over 0.5 m), : all laminar, with mm, mm (air has Pr < 1 and its thermal layer is somewhat thicker), and W/(m²·K). In the turbulent region, and .
The dimensionless numbers
Correlations are not written with , or alone but with dimensionless groups. That way one equation holds for any fluid and size with the same numbers:
| Number | Definition | What it compares |
|---|---|---|
| Reynolds | Inertia forces against viscous ones: it says whether the flow is laminar or turbulent. In a tube, . | |
| Prandtl | Momentum diffusion against heat diffusion; it is a fluid property: 0.7044 for air at 50 °C, 4.177 for water at 42 °C, 7.034 at 20 °C. | |
| Nusselt | Convection against conduction across a still layer of the same fluid: it is without dimensions. | |
| Grashof | Buoyancy from the density difference against viscosity: the «Reynolds» of natural convection. | |
| Rayleigh | The one natural-convection correlations use; on a vertical plate, the layer turns turbulent around . | |
| Graetz | The thermal entry length in a laminar tube (Hausen's correlation). |
The properties (, , , ) change with temperature and each correlation says at which to take them: the film temperature for the plate, the cylinder and natural convection, for the sphere and the bulk mean temperature in a tube. The tool reads them from the site's thermodynamic tables (air, water, nitrogen, oxygen, CO₂, helium, hydrogen, ethanol, R-134a) at that temperature and the pressure typed, and shows the property table used in the step by step; for another fluid choose «Other fluid» and its values.
External flow: plate, cylinder and sphere
The correlations the tool uses, with the range in which they hold (outside it the tool still gives the result but warns) and the temperature of the properties:
| Case | Correlation | Validity | Properties |
|---|---|---|---|
| Plate, laminar () | |||
| Plate, mixed (laminar then turbulent) | , | ||
| Plate, turbulent from the edge | same | ||
| Cylinder in crossflow (Churchill–Bernstein) | |||
| Sphere (Whitaker) | , , | ; at |
In the mixed plate, removes what the laminar region does not contribute; with it is 871.3. For the cylinder the tool also gives, for comparison, Hilpert's piecewise correlation, with and from a table of five Re intervals: simpler and of similar accuracy. With air at 10 m/s and a 25 mm tube (example 3), Churchill–Bernstein gives 64.26 and Hilpert ( = 0.193, = 0.618) 62.43.
If the heat is known instead of (a heater dissipating a power), the surface temperature is the unknown, but depends on it through the properties at . The tool finds it by bisection: leave «Surface Tₛ» empty and type the heat.
Internal flow in tubes
Inside a tube there is no : the fluid warms as it advances. One uses the bulk mean temperature (the one the well-mixed fluid would have), and the energy balance of the whole tube is
Near the inlet the boundary layers grow from the wall until they fill the tube: the flow develops in (velocity) and (temperature) in laminar flow, and in about 10 diameters in turbulent flow. Once developed, no longer changes with . The tool's correlations:
| Regime | Correlation | Validity and warnings |
|---|---|---|
| Laminar, fully developed | (wall at constant ) or (constant ) | ; it warns if the thermal entry is longer than the tube |
| Laminar with entry region (Hausen) | wall at constant | |
| Dittus–Boelter | , = 0.4 when the fluid is heated and 0.3 when cooled | , , |
| Gnielinski | , | (between 2300 and 3000 it warns: transition), |
Gnielinski is more accurate and holds from Re = 3000; Dittus–Boelter is the classic one, simpler, but only for well-developed turbulent flow. With the wall at constant temperature, the balance of a piece of the tube gives how approaches :
With a constant heat flux at the wall (an electric heater wound around it), rises along a straight line, , and the wall is always above the fluid. The properties go at the mean temperature , which depends on the outlet being sought: the tool iterates until it no longer changes. In example 4 (water at 0.1 kg/s, from 15 °C, in a 25 mm, 5 m tube with the wall at 90 °C), the mean is 41.96 °C, = 8079 (turbulent), Gnielinski gives = 53.55 and = 1351 W/(m²·K), and the water leaves at 68.93 °C.
Natural convection
Without a fan or a pump, the fluid moves by itself: next to a hot surface it warms up, expands, weighs less and rises; cold fluid replaces it. The driver is buoyancy, which depends on the expansion coefficient ; for an ideal gas (in kelvin). The tool computes it from the tables with a numerical derivative: for air at 50 °C it gives 0.003101 K⁻¹, almost . The correlations go with the Rayleigh number and the properties at :
| Geometry | Correlation | Validity |
|---|---|---|
| Vertical plate, height (Churchill–Chu) | all Ra (tested up to ~) | |
| Horizontal plate, hot face up (or cold face down) | up to ; beyond | , |
| Horizontal plate, hot face down (or cold face up) | , | |
| Horizontal cylinder (Churchill–Chu) | ||
| Sphere (Churchill) | , |
On a horizontal plate the characteristic length is the area over the perimeter; the face that «lets» the warm fluid escape upward convects better than the one that traps it underneath. In example 6 (0.5 m vertical plate at 75 °C in air at 25 °C), : laminar, below ; Churchill–Chu gives = 93.67 and = 5.261 W/(m²·K). Its laminar-only version would give 73.99: the complete one is what the tool uses.
Since grows with ( or ), doubling the temperature difference more than doubles the heat. And to find from a given heat the tool iterates as in external flow.
Thermal radiation: black and gray bodies
Every surface emits electromagnetic waves just by being at some temperature: it needs no medium and travels through vacuum. The blackbody is the ideal emitter: at each temperature and wavelength it emits the most possible and absorbs everything reaching it. Its spectral emission is Planck's law:
Two consequences can be read in the figure. The peak of each curve moves to shorter wavelengths as the temperature rises (Wien's law), and the area under the curve, the total emission, grows with the fourth power (Stefan–Boltzmann law):
The fraction in a band
What part of the emission falls between two wavelengths? Since depends only on , the fraction emitted below is a function of , , and that of a band is a subtraction:
The tool adds up that exact series (and for very large , the Bernoulli one of the tail) instead of reading a table. For the Sun at 5800 K, the visible band from 0.4 to 0.76 μm goes from = 2320 to 4408 μm·K: = 0.5500 − 0.1240 = 0.426, 42.6 % of its emission. A lamp filament at 2900 K gives only 10.01 % in the visible: the rest is heat.
The gray body
Real surfaces emit less than the blackbody. The emissivity (0 to 1) is the fraction; a gray body has the same at all wavelengths, so it emits with Planck's spectrum scaled down. A gray, diffuse surface absorbs the same fraction of what reaches it, (Kirchhoff's law), and if it is opaque it reflects the rest, . The tool treats surfaces as gray: you type the . A plate at 500 °C with = 0.6 emits 12 160 W/m² against the blackbody's 20 260, with its peak at 3.748 μm and 87.61 % above 3 μm.
View factors
Between two surfaces, not everything leaving one reaches the other: it depends on how they «see» each other. The view factor is the fraction of the radiation leaving surface that reaches directly. It depends only on the geometry, and obeys two rules that let one find some from others:
A flat or convex surface does not see itself (); a concave one does. The tool has the closed formulas of eight geometries: coaxial parallel disks, aligned parallel rectangles, perpendicular rectangles with a common edge, long (2D) plates that are parallel, inclined or perpendicular, and concentric cylinders and spheres. For example, two coaxial disks of radii , at a distance :
In a 4 × 3 m room, 2.5 m high, the ceiling sees the floor with = 0.2921, and the floor sees a 4 × 2.5 m wall with = 0.2035 (and the wall the floor with 0.2442, by reciprocity). In two concentric cylinders or spheres, the inner one sees only the outer one (), and the outer one sees itself: .
Exchange between gray surfaces and shields
What leaves a gray surface is what it emits plus what it reflects: the radiosity , with what reaches it. Its net heat and the exchange between two surfaces are written, once again, as resistances:
Two surfaces forming an enclosure (1 sees only 2) are three resistances in series between and :
| Geometry of the tool | Heat |
|---|---|
| Infinite parallel plates | |
| Long concentric cylinders | |
| Concentric spheres | |
| Small object in a large enclosure |
Two large plates at 527 and 227 °C with = 0.8 exchange 13 130 W/m²: the total resistance per m² is . If a thin shield of emissivity is placed between them, the heat has to cross two gaps and both faces of the shield: with equal shields the resistance grows by . A single shield with = 0.05 (polished aluminum) adds 39 and lets only 486.3 W/m² through, 96.3 % less, with the shield at 424 °C; with two, 247.7 W/m². It is the principle of the multilayer insulation of cryogenic tanks and satellites.
Convection and radiation together
A surface in air loses heat along both paths in parallel, to the fluid at and to the surroundings at (the walls of the room, enclosing it like a large enclosure). Radiation can be written with a radiation coefficient to compare it with :
A pipe at 150 °C with = 0.8 in a room at 25 °C with = 10 loses 1250 W/m² by convection and 1096 W/m² by radiation ( = 8.767): with natural convection, radiation weighs almost half and cannot be forgotten. The same balance explains the error of a thermocouple: inside a duct of hot gas with colder walls, the junction receives heat from the gas and loses it by radiation to the walls, and reads less than the gas (example 9).
Heat exchangers
An exchanger passes heat from a hot fluid to a cold one through a wall, without mixing them. The tool's types: parallel flow (both enter at the same end), counterflow (at opposite ends), shell and tube (one fluid in the tubes and the other in the shell, with 1 to 20 shell passes) and crossflow (one fluid perpendicular to the other, as in a radiator: both unmixed, or one of them mixed). There may be a fluid that condenses or boils at constant temperature.
The overall coefficient U and fouling
Between both fluids there are three resistances in series: convection inside, the wall and convection outside. Over time deposits form (scale, rust, algae) that add the fouling resistances . For a tube, referred to its outer area:
In the tool's example «U of a tube with fouling inside and outside» (22/25 mm tube, = 50, = 3000, = 2500, = 0.0002 and = 0.0001 m²·K/W), falls from 1233 W/(m²·K) clean to 878.7: almost 29 % less from two very thin layers of dirt. That is why exchangers are designed with spare area.
The log mean temperature difference (LMTD)
The temperature difference between the fluids changes along the exchanger. Through a piece passes ; the hot fluid drops and the cold one rises (or drops, in counterflow, depending on the direction) , with the heat capacity rate of each stream. Integrating from one end to the other:
and are the differences at both ends: in parallel flow and ; in counterflow and . With the same four temperatures counterflow has the largest and needs less area; besides, it lets the cold fluid leave hotter than the hot fluid's outlet, which is impossible in parallel flow.
For shell and tube and crossflow the counterflow with the same temperatures is used, multiplied by a correction factor , which depends on two temperature ratios (with the cold fluid in the tubes):
The tool does not read F from a chart: it computes it as from each arrangement's exact ε-NTU solution, and for one shell pass it also gives the closed formula for F, which agrees.
The effectiveness method, ε-NTU
When the outlets are unknown, the LMTD forces trial and error. The ε-NTU method avoids it. The maximum possible heat is that of an infinite counterflow exchanger, in which the stream with the smaller capacity rate would change by the whole inlet difference:
For each arrangement, ε is a function of NTU (the exchanger's size) and :
| Arrangement | |
|---|---|
| Parallel flow | |
| Counterflow | ( if ) |
| Shell and tube, 1 shell pass | |
| Shell and tube, passes | with of one pass with NTU/: |
| Crossflow, both unmixed | the exact series (the tool adds it up; the textbook approximation is shown beside it) |
| Crossflow, mixed | |
| Crossflow, mixed | |
| Any with (one fluid changes phase) |
At the same NTU counterflow is always the best and parallel the worst; with a small NTU they all look alike. Enlarging the exchanger pays less and less: the curves flatten. With the oil and water of example 10 (NTU = 1.408), counterflow passes 94.8 kW, crossflow unmixed 91.22 kW, shell and tube 89.01 kW and parallel flow 84.13 kW.
Rating or sizing
An exchanger has three equations: the two balances, and , and the rate equation, (or ). That is why the tool asks you to leave three unknowns empty (two if one fluid changes phase, because its balance disappears):
- Rating (an exchanger that already exists, with known U and A): both outlets and . With ε-NTU it is direct: NTU and give ε, ε gives , and the balances give the outlets (example 10).
- Sizing (what must be achieved is known): one outlet, and the area. The balances give the other outlet and ; then , or NTU from ε with the inverse formula (examples 11 and 12).
- Other combinations: a flow rate, an inlet or as the unknown. The tool solves the system (linear in the temperatures, and with a search on the flow rate when needed) and checks the second law: if an outlet would cross the other fluid's inlet, or if the ε asked for exceeds the arrangement's maximum, it says so (for example, that it would take an infinite exchanger).
The of water and the other fluids of the list is taken from the tables at each stream's mean temperature, which depends on the outlets: the tool iterates until it no longer changes. In a condenser (the tool's example «Condenser: steam at 50 °C and cooling water»), : with NTU = 1.794, ε = 1 − e⁻¹·⁷⁹⁴³ = 0.8338, 0.256 kg/s of steam condense and the water leaves at 44.18 °C.
Using the simulator
It is in Engineering → Thermodynamics and fluids → Heat transfer. In the «Heat transfer» panel, «What do you want to compute?» has six views; this topic uses «Convection», «Heat exchangers» and «Radiation» (the other three belong to the conduction topic). Below, «Case» picks the problem and «Examples» («Choose…») brings the examples of each view; on the right are the cards, the warnings, the figures and the «Step by step», recomputed with every keystroke, and the «Detailed solution (PDF)» button.
Convection
- Cases: «Flat plate», «Cylinder», «Sphere», «Tube (internal)» and «Natural».
- «Fluid»: the dropdown has air, water, nitrogen, oxygen, carbon dioxide, helium, hydrogen, ethanol and R-134a, with the «Pressure (absolute)»; their properties come from the site's tables at the temperature each correlation asks for, and the step by step shows the table used. «Other fluid (I type its properties)» opens «Density ρ», «Specific heat cₚ», «Viscosity μ» and «Conductivity k» (plus «Expansion β» for natural convection and «μₛ at the surface temperature» for the sphere).
- External flow: in «Flow and geometry», «Fluid T∞», «Velocity V» and «Length L (along the flow)» with «Width W (empty = per meter)» for the plate, or «Diameter D». In «Surface», «Surface Tₛ» or «Heat q (to find Tₛ)». The plate also has «Boundary layer»: «Transition Re_c», «Position x (optional)» (it gives the local and thickness) and «Turbulent from the leading edge».
- Tube: in «Tube and flow», «Inlet T_m,i», «Mass flow ṁ», «Inside diameter D» and «Length L»; in «Wall», «Constant temperature» (with «Wall Tₛ») or «Constant heat flux» (with «Wall flux q″ₛ»), and «Outlet T_m,o (empty = computed)»: leave one of the length, the outlet or the wall value empty. In «Correlation», «Turbulent» (Gnielinski or Dittus–Boelter) and «Laminar» («Fully developed (Nu = 3.66)» or «With entry region (Hausen)»).
- Natural: «Shape» («Vertical plate», «Horizontal plate, upper face», «Horizontal plate, lower face», «Horizontal cylinder» or «Sphere») with «Height L», «Side a» and «Side b» or «Diameter D», and in «Temperatures» «Fluid T∞», «Surface Tₛ» or the heat.
- Cards: «Mean coefficient», «Heat» (or per meter), Re, Nu and Pr, and depending on the case «Surface temperature», «Outlet temperature», «Length needed», «Wall temperature», «Wall heat flux» or «Wall at the outlet». The warnings say whether a correlation is outside its range (Pr, Re, Ra, L/D), whether the tube is in transition or whether there would be boiling or condensation next to the wall.
Heat exchangers
In «Arrangement», the «Type»: «Parallel flow», «Counterflow», «Shell and tube» (with «Shell passes»), «Crossflow, both unmixed», «Crossflow, hot fluid mixed» or «Crossflow, cold fluid mixed». «Hot fluid» and «Cold fluid» each have «Fluid» (or «Other (I type cₚ)»), «Mass flow ṁ», «Inlet» and «Outlet», and a box for phase change: «Condenses (constant temperature)» or «Boils (constant temperature)», with «Saturation temperature» and «h_fg (optional, for ṁ)». In «Transfer», «Overall coefficient U», «Area A» and «Heat q», or the «U from the resistances (with fouling)» box with «Tube (outer area)» or «Flat wall», «Inside D», «Outside D», «Wall k», hᵢ, hₒ and the fouling. Leave three unknowns empty (two with phase change).
Cards: «Heat» (with ε), «Hot outlet», «Cold outlet», «NTU» (with ), «Area and U», «Area needed» or «U needed», the with its F, what was solved for (an inlet or a flow rate, such as «Cold flow») and «U from the resistances» (with the clean value). The «Temperatures and effectiveness» figure gives the temperatures along the exchanger (parallel and counterflow) and the arrangement's ε-NTU curve with the operating point.
Radiation
| Case | What you type | What it gives |
|---|---|---|
| «Blackbody» | «Temperature T», «Emissivity ε», «Area (optional)» and «Emissive power E (to find T)»; in «Wavelength band», λ₁ and «λ₂ (empty = ∞)». | «Blackbody emission», «Planck peak», «Gray-body emission», «Power emitted», «Fraction in the band» and Planck's spectrum. |
| «Two surfaces» | In «Geometry», «Infinite parallel plates», «Long concentric cylinders», «Concentric spheres» or «Small object in a large enclosure» (with radii or area); T₁, ε₁, T₂, ε₂ and the heat; in «Radiation shields», «Number of shields» (plates) or «Shield radius (empty = no shield)», and «Shield emissivity». | «Net flux» or «Net heat», «Total resistance», «Shield temperature», «Reduction by the shields», «Radiosities» and the resistance network. |
| «View factor» | The «Surfaces» (eight geometries) and their dimensions; optional T₁ and T₂. | F₁₂, F₂₁ (reciprocity), «From 1 to the rest», «Areas» and «Heat if black». |
| «Convection + radiation» | In «Surface, fluid and surroundings», «Surface Tₛ», «Fluid T∞», «Surroundings T_sur», «Coefficient h», «Emissivity ε», «Area (empty = per m²)» and «Net heat leaving q»: leave one empty. | «Net heat per m²», «By convection», «By radiation» (with the share of each), «Radiation coef.» and what was solved for. |
Temperatures are typed in °C (or °F): the tool converts them to kelvin for radiation. The «SI» and «US» buttons in the header convert every field.
Common mistakes
- Taking the properties at the wrong temperature: at for the plate and the cylinder, at for the sphere, at the bulk mean in a tube.
- Using a correlation outside its range (Dittus–Boelter at Re = 5000, the laminar plate one at Re = 10⁶): read the warnings.
- Computing a tube's Re with the flow rate instead of the velocity or , or with the outside diameter.
- Using the arithmetic temperature difference in a tube or an exchanger: the one that gives the heat is the logarithmic mean.
- Putting temperatures in °C into : radiation always goes in kelvin. And forgetting radiation in natural convection, where it can be half of the heat.
- Confusing with : one goes from one to the other with reciprocity, .
- In the LMTD of a counterflow, pairing the ends as in parallel flow; and in shell and tube, forgetting the factor F.
- Computing with : it is always .
- Asking a parallel-flow exchanger for an effectiveness above : it is impossible, however large it is.
Worked examples
The fluid properties in the solutions are those the tool reads from the site's tables at the temperature given (it shows them in the step by step).
Example 1Air over a hot plate
Solution
- Film: °C. Air at 50 °C: m²/s, W/(m·K), .
- : laminar over the whole plate.
- and W/(m²·K).
- W. At the end, mm and W/(m²·K).
Solve it in Simuveliq
- In «What do you want to compute?» press «Convection» and in «Examples» choose Air at 5 m/s over a 0.5 m hot plate (laminar).
- Cards: «Mean coefficient» 12.38 W/(m²·K), «Heat» 371.3 W (q″ = 742.5 W/m²), Re = 139100 (laminar) and Nu = 220.3 (Pr = 0.7044).
- Type 0.5 in «Position x (optional)»: the «Local at x = 0.5 m» card gives 6.188 W/(m²·K) with δ = 6.703 mm.
Example 2Mixed boundary layer
Solution
- = 45 °C: m²/s, , . and m.
- Mixed: , W/(m²·K) and W.
- At 1 m, , turbulent: W/(m²·K), with mm.
Solve it in Simuveliq
- «Convection» → «Examples» → Air at 20 m/s over a 2 m plate: mixed boundary layer.
- Cards: «Mean coefficient» 45.08 W/(m²·K), «Heat» 3607 W, Re = 2.289×10⁶ (mixed) and «Local at x = 1 m» 51.3 W/(m²·K) (δ = 22.72 mm).
- Check «Turbulent from the leading edge» (a rough plate or one with a trip wire): the coefficient rises to 55.83 W/(m²·K) and the heat to 4466 W.
Example 3A tube in an air stream
Solution
- = 50 °C: , , . .
- Churchill–Bernstein: , so W/(m²·K).
- W.
- Hilpert, segment from 4000 to 40 000: , 3 % less.
Solve it in Simuveliq
- «Convection» → «Cylinder» → «Examples» → Air at 10 m/s around a 25 mm tube at 75 °C.
- Cards: «Mean coefficient» 72.19 W/(m²·K), «Heat» 283.5 W, Re = 13910 and Nu = 64.26. The step by step gives the comparison with Hilpert.
- Change the «Fluid» to water: the same tube has an of 30 570 W/(m²·K), over 400 times that of air.
Example 4Water heated in a tube
Solution
- The outlet is unknown and the properties go at the mean: iterate. With the final outlet, °C: Pa·s, , , J/(kg·K).
- : turbulent. Gnielinski: and , W/(m²·K).
- °C and W. Check: K and = 22 540 W.
Solve it in Simuveliq
- «Convection» → «Tube (internal)» → «Examples» → Water heated in a tube with the wall at 90 °C.
- Cards: «Outlet temperature» 68.93 °C, «Heat» 22540 W, «Mean coefficient» 1351 W/(m²·K) (Nu = 53.55), Re = 8079 (turbulent) and = 42.48 K.
- In «Correlation», change «Turbulent» to «Dittus–Boelter»: it leaves at 69.43 °C with = 1377 (and the warning that Re < 10 000).
Example 5How long a tube is needed?
Solution
- Now the outlet is given and the mean is fixed: = 37.5 °C, , Gnielinski and W/(m²·K).
- Solving the exponential: m.
- Heat: W, with K.
Solve it in Simuveliq
- «Convection» → «Tube (internal)» → «Examples» → What length heats the water from 15 to 60 °C?: «Length L» empty and the outlet typed.
- Cards: «Length needed» 3.809 m, «Heat» 18810 W, «Mean coefficient» 1280 W/(m²·K) and = 49.11 K.
Example 6A hot plate in still air
Solution
- = 50 °C: , m²/s, , and K⁻¹.
- : laminar.
- Churchill–Chu: , W/(m²·K) and W.
Solve it in Simuveliq
- «Convection» → «Natural» → «Examples» → Vertical 0.5 m plate at 75 °C in still air.
- Cards: «Mean coefficient» 5.261 W/(m²·K), «Heat» 131.5 W, Ra = 4.145×10⁸ and Nu = 93.67.
- This plate also radiates: in «Radiation» → «Convection + radiation», with h = 5.261, ε = 0.9 and the surroundings at 25 °C, you will see that radiation is of the same order.
Example 7The Sun as a blackbody
Solution
- W/m².
- Wien: μm, right in the visible.
- and μm·K: , 42.6 %, that is W/m².
Solve it in Simuveliq
- Press «Radiation» and in «Examples» choose The Sun as a blackbody at 5800 K: visible fraction.
- Cards: «Blackbody emission» 6.417×10⁷ W/m², «Planck peak» 0.4996 μm and «Fraction in the band» 42.6 %.
- Type λ₁ = 0.76 and leave «λ₂ (empty = ∞)» empty: the infrared takes 45 %.
Example 8A radiation shield
Solution
- In kelvin, 800.15 and 500.15 K: W/m².
- Without shield: W/m².
- With the shield, is added: W/m², 96.3 % less. The shield sits where W/m², that is at 424 °C.
Solve it in Simuveliq
- «Radiation» → «Two surfaces» → «Examples» → The same plates with a shield of emissivity 0.05.
- Cards: «Net flux» 486.3 W/m², «Total resistance» 40.5 1/m², «Shield temperature» 424 °C and «Reduction by the shields» 96.3 % (no shields: 13130 W/m²).
- Put 2 in «Number of shields»: 247.7 W/m².
Example 9The error of a thermocouple
Solution
- At equilibrium the junction neither gains nor loses: what it receives by convection it loses by radiation to the walls, .
- W/m².
- °C. The radiation coefficient is W/(m²·K).
Solve it in Simuveliq
- «Radiation» → «Convection + radiation» → «Examples» → Thermocouple in a duct: true gas temperature: «Fluid T∞» empty and «Net heat leaving q» = 0.
- Cards: T∞ = 186.2 °C (solved for), «By convection» −621.8 W/m², «By radiation» 621.8 W/m² and «Radiation coef.» 10.36 W/(m²·K).
- Change the emissivity to 0.1 (a polished junction or one with a shield): the error drops to 1 °C (T∞ = 181 °C).
Example 10Rating a counterflow exchanger
Solution
- W/K and W/K ( of water at its mean temperature): , .
- ; counterflow: .
- W; °C and °C.
Solve it in Simuveliq
- Press «Heat exchangers» and in «Examples» choose Oil–water counterflow: find the outlets. Both outlets and «Heat q» are empty.
- Cards: «Heat» 94800 W (ε = 0.6844), «Hot outlet» 61.03 °C, «Cold outlet» 57.8 °C, «NTU» 1.408 (Cr = 0.4249) and = 63.2 K.
- Change the «Type» to «Parallel flow»: the same unit passes 84130 W.
Example 11Sizing an exchanger
Solution
- Cold balance: W. Hot balance ( = 4185): °C.
- Counterflow ends: K and K; K.
- m². By ε-NTU the same comes out: , , .
Solve it in Simuveliq
- «Heat exchangers» → «Examples» → Size a counterflow: water from 20 to 60 °C: the hot outlet, «Area A» and «Heat q» empty.
- Cards: «Heat» 200600 W (ε = 0.856), «Hot outlet» 30.08 °C, «Area needed» 9.153 m² (UA = 10980 W/K) and = 18.26 K.
- Change the «Type» to «Parallel flow»: «Impossible with this arrangement…»: in parallel flow ε cannot exceed 0.5997.
Example 12Shell and tube: the factor F
Solution
- W and kg/s.
- Reference counterflow: K.
- and give , so m².
Solve it in Simuveliq
- «Heat exchangers» → «Examples» → Shell and tube (1 shell pass): area needed: the cold flow, «Area A» and «Heat q» empty.
- Cards: «Heat» 281300 W, «Area needed» 7.151 m², = 83.54 K with F = 0.9417 and «Cold flow» 1.923 kg/s.