Learn › Engineering

Cycle simulator: flowsheets and balances

A cycle problem describes which devices there are and how they are connected. The simulator writes it as a flowsheet: devices joined by streams, each stream with its pressure, enthalpy and mass flow, and each device with the equations of its model. Here you learn to set up a cycle that way —count unknowns and equations, see which datum is missing or extra, follow the order in which it is solved and check the result— and to use the simulator with regenerative cycles, two-stage, cascade refrigeration and the combined cycle.

From the cycle to the flowsheet

In the textbook a cycle is a sequence of states 1-2-3-4 on a T-s diagram. In a plant, and in the simulator, it is a flowsheet: each device (pump, boiler, turbine, condenser…) is a symbol with inlets and outlets, and each stream is the pipe that joins the outlet of one device to the inlet of the next. The state numbers of the textbook are the stream numbers: state 3 is the fluid going from the boiler to the turbine.

Each device is a steady-flow control volume, with the usual two laws (no kinetic or potential energy):

What the flowsheet adds is connectivity: the outlet of a device and the inlet of the next are the same stream, with the same state. That is why the whole cycle becomes a system of algebraic equations, one for each balance, each model and each datum of the problem. Instead of solving device by device «by eye», the full system is set up and solved in order.

1234BoilerTurbineCondenserPumpqin wt qout wp P₁, h₁, ṁ₁P₂, h₂, ṁ₂P₃, h₃, ṁ₃P₄, h₄, ṁ₄4 streams × 3 unknowns= 12 unknowns
The simple Rankine cycle as a flowsheet, numbered as the simulator's example: pump 1→2, boiler 2→3, turbine 3→4 and condenser 4→1. Each stream has three unknowns: its pressure, its enthalpy and its mass flow.

The streams joined through the devices form a loop, and a loop carries a single fluid. A heat exchanger separates two loops without mixing them: that is how cascade refrigeration (carbon dioxide below, ammonia above) or the combined cycle (air and combustion gases in one loop, water in the other) are built. A loop is closed if the fluid returns to its starting point (the water of a power plant) and open if it enters from and leaves to the outside (the air of a gas turbine, with an «Inlet» and an «Outlet» on the flowsheet).

The simulator numbers the streams in the order you create them (the smallest free number). If the problem uses another numbering, change the stream's «Number»: then the table and the step by step speak like your textbook.

The state of a stream: why P, h and ṁ

For a pure substance (water, a refrigerant, air treated as an ideal gas) the state postulate says that two independent intensive properties fix the state: with them the tables give all the others. A stream also needs how much fluid passes, the mass flow . That makes three numbers per stream, and the simulator chooses , and as the unknowns. Why those and not and ?

  • Inside the dome and are not independent. At 75 kPa water boils at 91.76 °C, and at that temperature it can be liquid, vapor or any mixture. Enthalpy does tell them apart: , so fixes the state inside the mixture too.
  • Enthalpy enters every balance linearly (): mixers, heaters, exchangers and powers are sums of flow × enthalpy products.
  • Pressure passes unchanged through many devices: a boiler with no pressure drop, a mixer, a splitter. Those equalities are the simplest equations of the system.
  • The valve is , a direct equality between unknowns.

With and known, the fluid properties (the same equations of state as «Thermodynamic tables») give , , the quality and the phase of each stream: that is the simulator's Stream table. Each datum you type becomes an equation on those unknowns:

Datum you typeEquation it addsWhere it is typed
Pressure valuestream, or the device (outlet pressure, heater pressure…)
Temperature valuestream, or the device's «Outlet condition»
Quality, saturated liquid or vaporstream («Quality x») or device (x = 0, x = 1)
Superheat or subcoolingthe device's «Outlet condition»
Saturation temperatureevaporator, condenser, heater, flash chamber
Mass flow, heat or power value, , stream, device, or the sheet's «Net power»
A saturated state is given by its quality, not its temperature: with and exactly the saturation the state can be liquid, vapor or a mixture, and the simulator says so («with P and that T the state may be liquid, vapor or a mixture; give the quality x»). For the same reason, at a condenser outlet choose «Saturated liquid (x = 0)» instead of typing the condensing temperature.

Each device is a set of equations

For each device you place, the simulator writes the equations of its model; the data you type on it add more. It pays to know them, because the degree-of-freedom count and the formulas of every exercise come from them.

Pump, compressor and turbine

One inlet and one outlet with the same flow (, the model equation). They are adiabatic: the work is the enthalpy difference, . The ideal machine would be isentropic; the real one is described by its isentropic efficiency , which compares the actual work with the ideal one between the same pressures. Solving for :

The efficiency is a datum (one more equation). If you leave it empty it becomes an unknown and another datum is needed instead, for example the measured outlet temperature: the simulator computes it and marks it «(computed)». The outlet pressure is given on the device, as a pressure ratio, or set by the next device (the condenser, the heater).

Valve

A throttling has no work and, in practice, no heat: the energy balance reduces to . Two model equations (flow and enthalpy). The outlet pressure is usually set by the device it feeds.

Devices that take in or reject heat

Boiler, heater, combustion chamber and evaporator (take in heat), condenser and cooler (reject it): same flow and constant pressure except for the drop you type, . The heat is not one more equation: it is the result , unless you give it as a datum. Their typical data are the pressure (or the saturation temperature) and the outlet condition: temperature, quality, saturated liquid or vapor, superheat or subcooling.

Mixer and open heater

Several inlets, one outlet: mass balance, energy balance and one pressure equality per inlet (in a mixing chamber all streams arrive at the same pressure). In the open heater of example 2 the extracted steam (stream 9, fraction ) mixes with the feedwater (2) and leaves as saturated liquid (3). Per kg leaving:

That is why «saturated liquid» is asked at the heater outlet: it is the datum that fixes the extracted fraction.

Splitter

One inlet and several outlets with the same state: mass balance and, for each outlet, and equal to the inlet ones. The fraction going to each outlet can be typed, but it is almost always unknown: the heater the extraction feeds fixes it.

Flash chamber

It receives a mixture and separates it at its pressure into saturated vapor (top) and saturated liquid (bottom): mass balance, energy balance, two pressure equalities, at the vapor outlet and at the liquid one. Combining the balances with :

The fraction leaving as vapor is the quality of the incoming mixture.

Closed heater, regenerator and heat exchanger

Two streams that do not mix: two mass balances, two pressure ones (each side with its drop) and one energy balance, (what the hot side gives the cold side receives). What is still missing is how much heat passes, and that is one more datum, one of these:

  • Terminal temperature difference (TTD, in feedwater heaters): . TTD = 0 is the textbook case: the water leaves at the saturation temperature of the extracted steam.
  • Effectiveness , with the heat if the cold side reached the hot inlet temperature, or the hot side dropped to the cold inlet one (the smaller of the two). It is the datum of gas-turbine regenerators.
  • An outlet temperature or condition of one of the sides (for example, the gases leave at 180 °C).

If, in addition, the flow of one side is unknown (the extraction going to a closed heater, the steam of a heat-recovery boiler), the outlet states of both sides are needed, and the balance gives the flow: in the closed heater, the drain leaves as saturated liquid and the TTD fixes the water outlet; in the heat-recovery boiler, the gas temperature and the steam one.

0100200300400500600050100150200250heat received by the feedwater (kJ per kg through the boiler)T (°C)2 · 46.30 °C310 · 217.13 °C7extracted steam: condenses at 187.96 °Cwater at 15 MPaTTD = Tsat (1.2 MPa) − T₃ = 0the water leaves at 187.96 °C
The closed heater of example 3 (steam extracted at 1.2 MPa, water at 15 MPa, TTD = 0), computed with the simulator's properties: the steam arrives at 217.13 °C, cools to saturation and condenses at 187.96 °C; the water rises from 46.30 to 187.96 °C. TTD = 0 is possible because at the water outlet end the steam is still superheated; inside, where it starts to condense, the difference is 4.99 °C.
DeviceModel equationsUsual data (one equation each)
Pump, compressor, turbine1: flowη; outlet pressure or ratio (or the next device sets it); power (optional)
Valve2: flow, outlet pressure (optional)
Boiler, heater, combustion chamber, evaporator, condenser, cooler2: flow, pressurepressure or ; outlet condition; heat (optional)
Mixer, open heater (n inlets)2 + n: mass, energy, n pressuresoutlet condition; pressure if no other device gives it
Splitter (n outlets)1 + 2n: mass, and of each outletfraction (hardly ever)
Flash chamber6: mass, energy, 2 pressures, , pressure or
Closed heater, regenerator, exchanger5: 2 flows, 2 pressures, energyTTD, ε or an outlet condition; heat (optional)
Inlet, outlet0, (and ) on the inlet stream

Degrees of freedom: counting unknowns and equations

With streams there are unknowns. The equations are those of each device's model () plus one per datum (). The problem is well posed when there are as many independent equations as unknowns. Two details change the count: in each closed loop one mass balance is redundant ( closed loops) and, if nothing fixes the size of the flow, the simulator adds a basis equation kg/s ():

Simple Rankine

DeviceModelData
Pump1 ()2: η = 100 %, = 3000 kPa
Boiler2 (, )1: = 350 °C
Turbine1 ()2: η = 100 %, = 75 kPa
Condenser2 (, )1:
Total66
Count6 + 6 − 1 (repeated mass balance) + 1 (basis kg/s) = 12= 3 × 4 unknowns ✓

The simulator's box summarizes it the same way: «Unknowns: 12 (P, h and ṁ of 4 streams) · equations: 13 (1 repeated mass balance in closed loop) · basis ṁ = 1 kg/s». The 13 equations include the basis one; without the repeated balance 12 remain, as many as unknowns.

Why one mass balance is redundant in a closed loop

In a closed loop each stream leaves one device and enters another. If the mass balances of all the devices are added up ( in each), every flow appears once with a plus sign and once with a minus sign:

The sum is zero whatever the flows are, so any one of the balances follows from the others: in the Rankine cycle, , and already imply . In an open loop (with an «Inlet» and an «Outlet») this does not happen, because the inlet and outlet flows appear only once.

What «basis ṁ = 1 kg/s» means

Mass and energy balances are linear and homogeneous in the flows, and the state data (pressures, temperatures, qualities, efficiencies) do not contain them. If a set of flows is a solution, the same set multiplied by any is one too:

The size of the flow is left free: it is the degree of freedom that a mass flow, a heat, a power or the sheet's net power fixes. If you give none, the simulator takes kg/s on the stream of largest flow (the one through the boiler in a regenerative plant) and everything comes out per kg of that stream, as in textbooks: each kW reads as kJ/kg. Efficiencies and COPs do not change; in «Sheet», «Calculation basis (ṁ = 1 kg/s)» lets you choose another reference stream. Each flow group with no size datum gets its basis; in a cascade or a combined cycle the exchanger joins the groups and one datum is enough for both loops.

Regenerative Rankine with an open heater

Example 2 has 9 streams: 27 unknowns. Model equations: boiler 2, high-pressure turbine 1, splitter 5 (mass and , of its two outlets), low-pressure turbine 1, condenser 2, pump 1 1, open heater 4 (mass, energy and two pressures), pump 2 1: 17 in total. Data: , η and pressure of each turbine, , η of each pump, at the heater and the pressure of pump 2: 10. With the basis and the repeated balance: 17 + 10 + 1 − 1 = 27 ✓. The heater pressure is not typed: it arrives with the extraction (1.2 MPa at the high-pressure turbine outlet) and pump 1 is «set by another device».

123456789BoilerHigh-pressure turbineSplitterLow-pressure turbineCondenserPump 1Open feedwater heaterPump 2
Regenerative Rankine with an open heater (example «Regenerative: open heater at 1.2 MPa»): 9 streams, 27 unknowns. Extraction 9 and water 2 mix in the heater; pump 1 takes the condensate to the heater pressure and pump 2 to the boiler pressure.

Reading the box: «Complete», «missing», «too many»

At the top of the «Data» panel a box counts the degrees of freedom live, while you type. Its messages are the diagnosis of your setup:

MessageWhat it meansWhat to do
«✓ Complete: as many data as degrees of freedom; solved in N steps.»Independent equations = unknowns, and the system was solved.Read the results and check them.
«N data missing. For example: …»There are fewer equations than unknowns. The table shows what could be computed so far.Find in the problem the datum that matches one of the suggestions (they are links to the device or stream).
«✓ N data more than needed, but they agree with the others.»You typed something that follows from the rest, and it agrees.Nothing; the step by step shows it under «Check of the equations left over».
«N data too many and they do not agree: …»A datum contradicts the others; the message says which and what value would come out without it.Check the problem: one of the two data is extra (or mistyped).

Examples on the simple Rankine: if you delete the boiler outlet temperature, «1 datum missing» appears with the suggestion «Boiler: how the fluid leaves (T, quality x, superheat, subcooling) or its heat Q̇.». If you delete the pump pressure, the suggestion is «A pressure: the outlet pressure (or the pressure ratio) of Pump (or the pressure (or the saturation temperature) of Boiler); it holds for streams 2, 3.»: pressures come in levels, and a single datum fixes all the streams joined by pressure equalities. If you also type = 350 °C on stream 3, the box says «✓ 1 datum more than needed, but they agree with the others.»; if you type 400 °C, «1 datum too many and they do not agree: «T = 350 °C» (Boiler) does not agree with the other data: with them it comes out 400 °C.». The simulator used one of the two data and checked the other: it does not know which one is right, that is your call.

The «missing» suggestions are possibilities: any of them closes the count, but only one is what your problem gives. In example 3 the closed heater datum is missing and the list also offers a mass flow or the splitter fraction; the physical datum that is missing is the terminal temperature difference.

Before counting, the simulator checks the structure and, if something makes no sense, says so instead of the box: unjoined points («Missing connections: …»), two fluids meeting in the same loop, or a closed loop with no pump or compressor («nothing brings the fluid back to the high pressure, so it is not a cycle»).

How it is solved: one unknown at a time

The simulator solves the way you would by hand, in order: it looks for an equation with a single unknown, solves it, marks it known and looks again. First come the data and the pressure and flow equalities between devices (the trivial steps), then each state with the two properties that fix it, then each machine with its efficiency, and the flows from the energy balances at the end.

pressures and flows: steps 1–8states: 9–12ṁ₁P₂ṁ₂P₃ṁ₃P₄P₁ṁ₄h₁h₂h₃h₄1ṁ₁ = 1 kg/s · basis2P₂ = 3000 kPa · pump3ṁ₂ = ṁ₁ · pump4P₃ = P₂ · boiler5ṁ₃ = ṁ₂ · boiler6P₄ = 75 kPa · turbine7P₁ = P₄ · condenser8ṁ₄ = ṁ₃ · turbine9x₁ = 0 · condenser10η = 100 % · pump11T₃ = 350 °C · boiler12η = 100 % · turbine✓ṁ₁ = ṁ₄ · condenser■ unknown it solves · ● already known · ✓ balance left over: it is checked
The 13 equations of the simple Rankine in the order the simulator uses them (rows) and the 12 unknowns in the order they come out (columns). Each equation contains only unknowns already known (●) and one new one (■): the matrix is triangular, so no system has to be solved. The last row, the redundant mass balance, is only checked.

In the simple Rankine: = 3000 kPa (pump datum) and ; = 75 kPa (turbine datum) and ; = 1 kg/s (basis) and the other flows equal; (75 kPa) = 384.44 kJ/kg; = 387.47 kJ/kg with the pump; = 3116.1 kJ/kg with and ; = 2403 kJ/kg with the turbine. Twelve steps, one per unknown: the box says «solved in 12 steps».

Blocks solved together

Sometimes no equation has a single unknown. In the open heater, once all the enthalpies are known, two flows are still unknown (the extraction, , and the one continuing through the low-pressure turbine, equal to ) and two equations contain both: the splitter mass balance and the heater energy balance. The simulator recognizes them as a block and solves them together; the step by step says «No equation has a single unknown: these two are solved together (linear system)»:

Unknowns tied by simple equalities (flow through a device, equal pressures) count as one, so the block is the 2 × 2 you would write by hand and not one of ten equations. If the block is not linear (for example, with an unknown effectiveness or pressure ratio), it is solved with Newton's method. There is a third kind of step: a stream with two state data and no known pressure, such as = −5 °C and saturated liquid in the cascade, gets its pressure from saturation, (−5 °C).

In the closed heater no block is needed: the cold-side flow is all the feedwater (the basis), so its energy balance has a single unknown, the extracted flow. The step by step and the «Detailed solution (PDF)» follow exactly this order, with each equation written, substituted and solved.

Several loops: cascade and combined cycle

Each loop has its fluid, its repeated mass balance if it is closed and its own flow size. The only thing joining two loops is the exchanger: it does not mix the streams, so there is no flow equality between them; only the energy balance relates the flows of the two loops. With the enthalpies known, that balance gives the flow ratio, and a single size datum (the capacity, the net power) is enough for both.

Cascade refrigeration

To cool at −40 °C and reject heat at 35 °C with a single refrigerant would require a huge pressure ratio and a very inefficient compressor. The cascade splits the lift into two cycles: the lower one (CO₂) evaporates at −40 °C and condenses at −5 °C in the exchanger; the upper one (ammonia) evaporates at −10 °C in that same exchanger and condenses at 35 °C. Each fluid works in its range: CO₂ at −40 °C is at 1004.5 kPa, above the atmosphere.

12345678Condenser (high loop)Valve (high loop)Compressor (high loop)Cascade heat exchangerCompressor (low loop)Valve (low loop)Evaporator (low loop)loop 2 · ammonialoop 1 · CO₂Q̇L = 50 kW−5 °C−10 °C
Cascade refrigeration (example «Cascade refrigeration: CO₂ and ammonia»): two closed loops, each with its fluid, joined only by the cascade exchanger. The 50 kW capacity at the evaporator fixes the CO₂ flow, and the exchanger balance, the ammonia one.

The count: 8 streams, 24 unknowns; the box says «equations: 26 (2 repeated mass balances in closed loops)» and adds no basis, because the 50 kW fix the size of the CO₂ loop and the exchanger passes it on to the ammonia loop.

0.40.91.41.92.4−60−40−20020406080100120140s (kJ/kg·K)T (°C)0123456−60−40−20020406080100120140s (kJ/kg·K)loop 1 · CO₂loop 2 · ammonia12345678band: CO₂ condenses at −5 °Cand ammonia boils at −10 °C
The two loops of the cascade on T-s with their real properties, on the same temperature axis (entropies of two different fluids cannot be compared, temperatures can). The band is the exchanger: CO₂ (3) condenses 5 °C above where ammonia boils (5, 8); that difference is what drives the heat.

Combined gas–steam cycle

Gases leave a gas turbine above 600 °C: throwing them away like that wastes a lot of high-temperature energy. In the combined cycle, a heat-recovery steam generator (an exchanger) uses those gases to raise the steam of a Rankine cycle. The air side is an open loop (air enters from the atmosphere, gases leave through the stack: no repeated balance), the water side a closed loop. The net power of 100 MW is that of both cycles together, so the two flows come out of a 2 × 2 block: the recovery boiler balance and the net power one.

02550751001250100200300400500600700heat transferred Q̇ (MW), from the cold endT (°C)pinch: 349.10 − 295.01 = 54.1 °C4 · gas 630.97 °C578 · 450 °Ceconomizerevaporator (8 MPa, 295.01 °C)superheater
The heat-recovery steam generator of example 7 on a T–Q diagram, with the simulator's properties (air with variable specific heats, water at 8 MPa). The water warms up (economizer), boils at 295.01 °C (evaporator) and is superheated to 450 °C. The narrowest point, the pinch, is where the water starts to boil: the gases are at 349.10 °C there, 54.1 °C above. If the gases were asked to leave at 90 °C, the gas curve would cut the water one at that point (293.73 °C against 295.01 °C) although the ends do not cross, and the simulator rejects it: «the temperatures cross inside».

Where does the combined-cycle efficiency come from? From the gas-side balance: the combustor heat splits into the gas turbine net power, the recovered heat and the energy leaving through the stack, . With :

fuel219.96 MWgas turbineheat-recovery boiler120.39 MWẆnet,G 60.46 MWẆnet,S 39.54 MWcondenser 80.85 MWexhaust 39.11 MWnet Ẇ = 60.46 + 39.54 = 100 MW · η = 100/219.96 = 45.46 %
Where the 219.96 MW of the combustor of example 7 go: 60.46 MW leave as gas turbine net work, 120.39 MW pass to the steam cycle (which gives 39.54 MW net and rejects 80.85 MW at the condenser) and 39.11 MW leave with the gases at 180 °C. Neither the gas turbine (27.49 %) nor the steam cycle (32.84 %) reaches the 45.46 % of the whole.

Piston engines: processes of one charge

In a piston engine (Otto, Diesel or dual, also called Sabathé) there is no steady flow: the same charge of air is compressed, receives heat, expands and rejects heat inside the cylinder. The simulator writes it with the blocks of the Piston engine group of the palette: each block is a process of the charge and each stream a state (1, 2, 3…), with the same three unknowns P, h and ṁ. The «flow» is the mass of the charge times the cycles per second; without that datum, ṁ = 1 kg/s and the results come out per kg of charge, as in the textbook.

Each block is a closed system: the first law without flow enthalpies, with the internal energy and, for an ideal gas, :

BlockModel equationsUsual data
Compression in the cylinderflow; ; (or the final pressure) and η
Heat at constant volumeflow; ; , the heat per kg or the final temperature
Heat at constant pressureflow; ; and , the heat per kg or the final temperature
Expansion in the cylinderflow; ; η (the final volume is set by the rejection)
Heat rejection at constant volumeflow; ; none (or the heat rejected)

The ideal compression and expansion are isentropic between the same volumes, because the cylinder geometry fixes the compression ratio: with constant specific heats is conserved; with the air table, the relative volume changes as the volume, . An efficiency η compares the real work with that ideal one. The expansion needs no volume datum: the constant-volume rejection takes it back to the volume at the start of the compression, and the simulator solves that last state in a single step, with its volume and the isentrope.

12345CompressionHeat at const. vHeat at const. PExpansionRejection at const. vwc we q23 q34 qout v = constP = constv = const100 kPa · 300 K×1.4 at const. v1900 Kr = 16 · air table5 states × 3 unknowns = 15
The dual engine of example 8 with the piston blocks: compression 1→2, heat at constant volume 2→3 (the pressure rises 1.4 times), heat at constant pressure 3→4 up to 1900 K, expansion 4→5 and rejection at constant volume 5→1. Works in green, heats in red.
The piston blocks only take an ideal gas (air from the table, or the gas of constant cₚ and k, with an optional cᵥ like the cold-air standard of «Thermodynamic cycles»), and a loop is either piston or flow, not both. The maximum temperature is typed on the stream leaving the heat block; the total heat of a dual cycle and the mean effective pressure go in «Sheet».

Checking the results

That the system solves does not mean the cycle makes sense. The simulator makes these checks, and it is worth knowing how to make them by hand in an exam:

  • Overall energy balance. For the whole cycle, (plus the inlet and outlet flows in an open loop). It is the «Energy balance» card with ✓. In example 2: 2769.2 − 1486.7 − 1282.5 = 0 kJ/kg.
  • Carnot. The efficiency cannot exceed between the highest temperature at which heat enters and the lowest at which it leaves (in kelvin), nor the COP . The cards show it alongside («Carnot 63.47 %») and a result above it is an error.
  • Second law in each device. In an adiabatic device : a turbine or compressor whose computed efficiency is above 100 %, an exchanger with crossing temperatures or a «hot» side colder than the «cold» one are impossible, and the simulator says so.
  • Orders of magnitude. The back work ratio is about 1 % in a Rankine cycle and about 40 % in a gas turbine; the quality at a steam turbine exit should stay above ~88 % (the simulator warns below it); an extraction flow is a fraction, between 0 and 1.

A second-law example: the open heater of example 2 is adiabatic but irreversible, because it mixes steam at 217.13 °C with water at 45.85 °C. Per kg leaving:

That is why the «ideal» cycle with an open heater does not have the efficiency of a Carnot cycle between its mean temperatures: at the condenser it rejects times the entropy it received plus the one the mixing generated. Even so it gains, because the water enters the boiler at 190.0 °C instead of 46.3 °C and the mean temperature at which it receives heat rises from 286.7 °C to 347.2 °C.

01234567890100200300400500600s (kJ/kg·K)T (°C)T̄H = 347.2 °CT̄H = 286.7 °Cgreen: with heater (46.31 %)red: without heater (43.03 %)1, 23, 456, 8, 97mixing in theheater
Example 2 on T-s, computed with the simulator's properties. Red dashed, the part of the water heating (from 46.3 to 190.0 °C) that the boiler would do without the heater; with it, the extracted steam does it. The mean temperature of heat addition, , rises from 286.7 °C to 347.2 °C and the efficiency from 43.03 % to 46.31 %. The thin dashed lines are the mixing in the heater.

Using the simulator

It is in Engineering → Thermodynamics and fluids → Cycle simulator. On the left the panels Data, Fluid of each loop, Sheet and Examples; in the middle the Flowsheet canvas; below, the results. Everything is SI: absolute pressures in kPa, temperatures in °C or K (chosen in «Sheet»), efficiencies and effectiveness in %, powers and heats in kW. It recomputes as you type.

  • Palette, above the canvas, in six groups: Machines (Pump, Compressor, Turbine, Valve), Heat (Boiler, Heater, Combustor, Evaporator, Condenser, Cooler), Mixing and separation (Open heater, Mixer, Splitter, Flash tank), Exchangers (Closed heater, Regenerator, Exchanger), Boundaries (Inlet, Outlet) and Piston engine (Compression, Heat at const. v, Heat at const. P, Expansion, Rejection at const. v). Choose one and click the canvas to place it.
  • Connect: drag from an outlet (filled dot) to an inlet (hollow dot), or tap one and then the other (on a phone). An unjoined inlet shows in red. Canvas buttons: «Move», «Connect», «Delete», «−», «+» and «Fit»; the wheel zooms and dragging the background pans. Dragging the middle segment of a stream moves it aside.
  • A device: tap it and «Data» shows its «Name», its data and the buttons «Rotate 90°» (or the R key), «Flip» and «Delete». Machines: «Outlet pressure» as «Pressure», «Ratio» or «Set by another device», and «Isentropic efficiency η» (100 % = ideal; empty = unknown), with «Power taken (optional)» or «Power produced (optional)». Heat devices: «Pressure», «Saturation T», «Outlet condition» (— (no datum), Temperature, Quality x, Saturated liquid (x = 0), Saturated vapor (x = 1), Superheat, Subcooling), «Heat received (optional)» or «Heat rejected (optional)» and «Pressure drop». Mixers: «Inlets» (2 or 3); splitter: «Outlets» and «Fraction to outlet 2»; exchangers: «Exchanger datum» («Terminal temperature difference (TTD)» or «Effectiveness ε»), the outlet conditions of the «Hot side» and the «Cold side», «Heat transferred (optional)» and the pressure drops.
  • A stream: tap it (or its number) to see «Known data (leave empty what you do not know)» —«Pressure P», «Temperature T», «Quality x», «Mass flow ṁ»—, its «Number», «Automatic route», «Delete stream» and, below, the computed state (T, P, h, s, phase, ṁ).
  • Fluid of each loop: one dropdown per loop («Loop 1 · streams 1, 2, 3…») with water, refrigerants, real gases and organic liquids from the tables, «Air (ideal gas, variable specific heats)» or «Ideal gas with constant cₚ and k» (asks for cₚ and k; cold-air standard: 1.005 and 1.4).
  • Sheet: «Temperatures in» °C or K, «Net power (optional)» in kW, «The cycle is used to» («Cool (refrigerator)» or «Heat (heat pump)», when there is an evaporator) and, if results are per kg, «Calculation basis (ṁ = 1 kg/s)». Examples: «Load an example», «Blank sheet» and «Fit the drawing».
  • Results: cards («Thermal efficiency» with Carnot, «Net work» or «Net power», «Heat in», «Heat out», «Back work ratio», «Energy balance»; in refrigeration «Refrigeration COP», «Heat-pump COP», «Cooling capacity», «Compressor power»); Diagrams of each loop (T-s, and P-h for refrigeration loops); Stream table (T, P, h, s, x or phase, ṁ); Devices: work, heat and efficiency (with the efficiency «(given)» or «(computed)», the pressure ratio, the splitter fractions, ε and TTD); Step by step in solving order, and the Detailed solution (PDF) button, with the flowsheet, the degree-of-freedom count, each equation substituted and solved, the balances and the checks.
  • From «Thermodynamic cycles»: the Rankine, Brayton, refrigeration, Otto, Diesel and dual cycles have the «Cycle simulator» section with the «Open in the cycle simulator» button, which builds the equivalent flowsheet with the same data. It is the fastest way to go from a textbook cycle to one you can modify (add a heater, another stage, another loop, an efficiency in the compression).
A work order that avoids almost every problem: 1) place and join all the devices; 2) choose the fluid of each loop; 3) type the data device by device; 4) watch the box until it says «✓ Complete»; 5) check the energy balance and Carnot before reading the numbers. ↶ undoes any change.

Common mistakes

  • Typing the same pressure twice: the extraction turbine outlet and the open heater pressure. It is one datum too many; if they differ, the simulator says «The inlets of Open feedwater heater arrive at different pressures…».
  • Giving the temperature of a saturated state instead of its quality (x = 0 or x = 1).
  • Forgetting the pump before the open heater: all the streams of a mixer arrive at the same pressure, and the condensate is at the condenser pressure.
  • Connecting an exchanger the wrong way round: heat does not flow from cold to hot and the temperatures cannot cross.
  • Mixing two fluids in a loop; to pass heat from one fluid to another, use an exchanger.
  • Typing the efficiency as a fraction (0.85) in a field that is in % (85).
  • Expecting kW without giving any flow, heat or power: the results come out per kg of the basis stream (the card says so: «per kg of stream N»).
  • Reading the extracted fraction «per kg entering the low-pressure turbine»: the simulator gives it per kg of the basis stream, which in a regenerative plant is the one through the boiler.

Worked examples

Example 1Simple Rankine from a blank sheet

An ideal water Rankine cycle receives steam at 3 MPa and 350 °C in the turbine and condenses at 75 kPa. Set it up as a flowsheet, count the degrees of freedom and find the works, the heats, the efficiency and the quality at the turbine exit.
1234BoilerTurbineCondenserPumpqin wt qout wp 75 kPa · x = 03000 kPa3000 kPa · 350 °C75 kPawater · ideal (η = 100 %)results per kg

Solution

  1. Devices and streams: pump, boiler, turbine and condenser; streams 1 (condenser → pump), 2 (pump → boiler), 3 (boiler → turbine) and 4 (turbine → condenser). 12 unknowns.
  2. Count: 6 model equations and 6 data (η and = 3000 kPa of the pump, = 350 °C, η and = 75 kPa of the turbine, ); minus the repeated mass balance and plus the basis = 1 kg/s: 12 = 12.
  3. Pressures and flows: = 3000 kPa, = 75 kPa, all flows 1 kg/s.
  4. Stream 1, saturated liquid at 75 kPa: = 91.76 °C, = 384.44 kJ/kg, = 1.2132 kJ/kg·K. Pump: = 387.47 kJ/kg, and with η = 100 % = 387.47 kJ/kg ( = 3.032 kJ/kg).
  5. Stream 3 (3000 kPa, 350 °C, superheated vapor): = 3116.1 kJ/kg, = 6.7449 kJ/kg·K. Turbine: at 75 kPa with , and = 2403.0 kJ/kg.
  6. = 3116.1 − 2403.0 = 713.04 kJ/kg; = 3116.1 − 387.47 = 2728.6 kJ/kg; = 2403.0 − 384.44 = 2018.6 kJ/kg; = 713.04 − 3.03 = 710.01 kJ/kg; = 710.01/2728.6 = 26.02 %. Check: 2728.6 − 2018.6 − 710.0 = 0.
= 26.02 % (Carnot 41.44 %), = 710.01 kJ/kg, = 0.8861, back work ratio 0.4252 %.

Solve it in Simuveliq

  1. «Blank sheet». In the palette, Heat → «Condenser» and click the canvas; Machines → «Pump»; Heat → «Boiler»; Machines → «Turbine». Rotate with «Rotate 90°» whichever suits you.
  2. Join in this order so the numbering matches: condenser → pump (1), pump → boiler (2), boiler → turbine (3), turbine → condenser (4). «Fluid of each loop»: Water.
  3. Data: Pump, «Outlet pressure» 3000; Boiler, «Outlet condition» Temperature and «Outlet temperature» 350; Turbine, «Outlet pressure» 75. The efficiencies are already 100 % and the condenser already delivers «Saturated liquid (x = 0)». The box turns to «✓ Complete: … solved in 12 steps.» (the button opens this same flowsheet already built).
  4. Cards: «Thermal efficiency» 26.02 % (Carnot 41.44 %), «Net work» 710.01 kJ/kg (turbines 713.04 − pumps and compressors 3.032), «Heat in» 2728.6, «Heat out» 2018.6, back work 0.4252 %. Type «Mass flow ṁ» 2 on stream 1: the basis disappears and everything turns into kW (1420 kW net) with the same efficiency.

Example 2Regenerative with an open heater: the block that fixes the extraction

An ideal plant: steam at 15 MPa and 600 °C, condenser at 10 kPa and an open heater fed with steam extracted at 1.2 MPa, which delivers saturated liquid. Find the extracted fraction, the efficiency and compare it with the same plant without heater.
123456789BoilerHigh-pressure turbineSplitterLow-pressure turbineCondenserPump 1Open feedwater heaterPump 2

Solution

  1. 9 streams, 27 unknowns; 17 model equations + 10 data + basis − 1 repeated balance = 27 (see the degrees-of-freedom section). Basis: 1 kg/s through the boiler.
  2. States: = 191.81 (saturated liquid at 10 kPa); pump 1 to 1.2 MPa, = 193.01; = 798.33 (saturated liquid at 1.2 MPa, 187.96 °C); pump 2 to 15 MPa, = 813.98; = 3583.1 ( = 6.6796); high-pressure turbine to 1.2 MPa, = 2858.8 (217.13 °C); low-pressure turbine to 10 kPa, = 0.8041 and = 2115.2 kJ/kg.
  3. Splitter + heater block: ; = 0.77293 continues through the low-pressure turbine.
  4. Works per kg through the boiler: high-pressure turbine 3583.1 − 2858.8 = 724.35; low-pressure turbine 0.77293 × (2858.8 − 2115.2) = 574.70; pumps 0.77293 × 1.20 + 15.65 = 16.576; = 1299.1 − 16.58 = 1282.5 kJ/kg.
  5. = 3583.1 − 813.98 = 2769.2 kJ/kg; = 0.77293 × (2115.2 − 191.81) = 1486.7 kJ/kg; = 1282.5/2769.2 = 46.31 %.
  6. Without heater (the same simple plant): = 3583.1 − 206.90 = 3376.2 kJ/kg and = 43.03 %. The heater gains 3.3 points because the water enters the boiler at 190.0 °C instead of 46.3 °C.
= 0.2271, = 46.31 % (without heater 43.03 %), = 1282.5 kJ/kg.

Solve it in Simuveliq

  1. Examples → «Load an example» → «Regenerative: open heater at 1.2 MPa».
  2. The box: «Unknowns: 27 (P, h and ṁ of 9 streams) · equations: 28 (1 repeated mass balance in closed loop) · basis ṁ = 1 kg/s», solved in 26 steps. In the step by step, «No equation has a single unknown: these two are solved together (linear system)» with = 0.22707 kg/s.
  3. Cards: 46.31 % (Carnot 63.47 %), 1282.5 kJ/kg, 2769.2 and 1486.7 kJ/kg, back work 1.276 %. In the device table, the splitter: «y₁ = 0.7729 · y₂ = 0.2271». Also type 1200 in the open heater «Pressure»: «✓ 1 datum more than needed, but they agree with the others.»

Example 3Which datum is missing? The closed heater

The same plant (15 MPa, 600 °C, 10 kPa, extraction at 1.2 MPa) with a closed heater: the feedwater passes through it at 15 MPa and the extracted steam condenses and leaves as saturated liquid, which is throttled to the condenser. The flowsheet of the button is almost complete but says «1 datum missing». Which one is it? Solve with the water leaving at the saturation temperature of the extracted steam (TTD = 0) and then with TTD = 3 °C.
1234567891011BoilerHigh-pressure turbineSplitterLow-pressure turbineMixerCondenserPumpClosed feedwater heaterSteam trap

Solution

  1. Count: 11 streams, 33 unknowns. The box gives «equations: 33 (1 repeated mass balance…) · basis»: 32 independent. The closed heater has 5 model equations and its hot outlet condition (saturated liquid), but nothing says how much the water is heated: its specification is missing. The other suggestions (a flow, the splitter fraction, the mixer outlet) would also close the count, but they are not data of the problem.
  2. TTD = 0: = 187.96 °C and, at 15 MPa, = 805.02 kJ/kg. The drain: (1.2 MPa) = 798.33 kJ/kg; the extraction, = 2858.8 kJ/kg; the water arrives from the pump with = 206.90 kJ/kg.
  3. Closed heater balance, with a single unknown (the cold side is all the water, 1 kg/s): , .
  4. Mixer before the condenser: = 1732.96 kJ/kg (the throttled drain, , with quality 0.2536 at 10 kPa).
  5. = 724.35 + 0.70972 × 743.54 = 1252.1 kJ/kg; = 15.096; = 1237.0; = 3583.1 − 805.02 = 2778.1 kJ/kg; = 44.53 %.
  6. With TTD = 3 °C the water leaves at 184.96 °C ( = 791.91): = 0.28392 and = 44.49 %. Both below the open heater (46.31 %): the hot drain is throttled and its energy goes to the condenser.
The closed heater specification is missing. TTD = 0: = 0.2903, = 44.53 %; TTD = 3 °C: = 0.2839, = 44.49 %.

Solve it in Simuveliq

  1. The button opens the plant without the datum. The box says «1 datum missing. For example:» and the first suggestion is «Closed feedwater heater: the terminal temperature difference, the effectiveness or an outlet temperature of one of its sides.»: tap it and the device is selected.
  2. In «Exchanger datum» choose «Terminal temperature difference (TTD)» and type 0: «✓ Complete… solved in 33 steps.», with 34 equations. The heater step: «the heat given by the hot side is received by the cold one» with = 0.29028 kg/s; there is no block.
  3. Cards: 44.53 %, 1237 kJ/kg, 2778.1 kJ/kg; in the device table the closed heater with Q̇ = 598.12 and TTD = 0 °C. Change the TTD to 3: 44.49 % and = 0.28392 kg/s. «Load an example» → «Regenerative: closed heater (drain to the condenser)» is the complete version.

Example 4Real refrigerator: the compressor efficiency as an unknown

A R-134a refrigerator circulates 0.05 kg/s. It enters the compressor at 140 kPa and −10 °C and leaves at 800 kPa and 50 °C; it leaves the condenser at 26 °C with a pressure drop of 80 kPa, and enters the evaporator at 150 kPa (10 kPa more than at its outlet). Find the heat removed, the power, the compressor isentropic efficiency and the COP.
1234EvaporatorCompressorCondenserValve140 kPa · −10 °C · 0.05 kg/s800 kPa · 50 °C26 °C150 kPaΔP = 10 kPaΔP = 80 kPaη = ?

Solution

  1. Count: 4 streams, 12 unknowns. Data: , , , , , (6); model: 4 mass balances, 2 pressure ones with their drop and the valve (7). 6 + 7 − 1 = 12, no basis because the flow is given. The compressor efficiency is left empty: it is an unknown that comes out of the states.
  2. States: = 246.36 kJ/kg ( = 0.97237); = 286.70 kJ/kg; = 800 − 80 = 720 kPa, liquid at 26 °C, = 87.83 kJ/kg; valve, at 150 kPa: a mixture with = 0.2778 at −17.13 °C.
  3. = 7.926 kW; = 2.017 kW; = 9.943 kW.
  4. Isentropic compression: = 284.17 kJ/kg; = 93.74 %.
  5. COP = 7.926/2.017 = 3.93 (Carnot 7.31); as a heat pump 4.93.
= 7.926 kW, = 2.017 kW, = 93.74 %, COP = 3.93.

Solve it in Simuveliq

  1. «Load an example» → «Real refrigerator: measured states, compressor efficiency». The data are on streams 1, 2 and 3 and in the «Pressure drop» of the evaporator (10) and the condenser (80); the compressor has an empty «Isentropic efficiency η» and «Set by another device».
  2. Box: «Unknowns: 12 … · equations: 13 (1 repeated mass balance in closed loop)», no basis. Cards: «Refrigeration COP» 3.93 (Carnot 7.31), «Cooling capacity» 7.9264 kW, «Compressor power» 2.0169 kW, «Heat rejected» 9.9433 kW.
  3. In «Devices: work, heat and efficiency», the compressor: «η = 93.74 % (computed)». Type 90 as its efficiency: now there is one datum too many and it does not agree with .

Example 5Two-stage refrigeration with a flash chamber

An ideal R-134a cycle works between 0.14 and 0.8 MPa with two-stage compression. The condenser liquid is throttled to 0.32 MPa into a flash chamber; the separated vapor mixes with the low-pressure compressor discharge and the liquid is throttled to the evaporator. Find the fraction that flashes in the chamber, the heat removed and the work per kg through the condenser, and the COP; compare with a single stage.
123456789CondenserHigh-pressure valveFlash chamberLow-pressure valveEvaporatorLow-pressure compressorMixing chamberHigh-pressure compressor320 kPa800 kPa140 kPa

Solution

  1. Count: 9 streams, 27 unknowns; results per kg of stream 4 (the condenser one, the basis). The flash chamber brings 6 equations and its pressure is a datum.
  2. (0.8 MPa) = 95.50 kJ/kg; the high-pressure valve gives = 95.50 at 0.32 MPa, a mixture with = 0.2049. The chamber separates = 251.90 and = 55.19 kJ/kg; as derived above, the vapor fraction is = 0.2049.
  3. The simulator gets it as a block (mass and energy of the chamber): = 0.20492 and = 0.79508 kg per kg through the condenser.
  4. Evaporator: (0.14 MPa) = 239.18, = 55.19: = 0.79508 × 183.98 = 146.28 kJ/kg. Low-pressure compressor to 0.32 MPa: = 255.92, work 0.79508 × 16.74 = 13.313 kJ/kg.
  5. Mixing chamber: = 255.10 kJ/kg; high-pressure compressor to 0.8 MPa: = 274.47, work 19.373 kJ/kg. Total 32.686 kJ/kg.
  6. COP = 146.28/32.686 = 4.475, versus 3.968 for the single-stage cycle between the same pressures: the vapor formed in the first expansion goes neither through the evaporator nor through the low-pressure compressor.
Flashed fraction 0.2049, = 146.28 kJ/kg, = 32.686 kJ/kg, COP = 4.475 (single stage: 3.968).

Solve it in Simuveliq

  1. «Load an example» → «Two stages with a flash chamber (R-134a)». The pressures are on the condenser (800), the flash chamber (320) and the evaporator (140); the compressors, ideal, with the outlet pressure set by another device.
  2. Cards: «Refrigeration COP» 4.475 (Carnot 5.079), «Cooling capacity» 146.28 kJ/kg, «Compressor power» 32.686 kJ/kg, «per kg of stream 4». In the device table, the flash chamber: «vapor: 0.2049 of the flow».
  3. Comparison: «Ideal R-134a refrigeration: 0.14 and 0.8 MPa» gives 3.968 with 7.1837 kW for 0.05 kg/s. In the diagrams of each loop, the P-h shows the two expansions and the two compressions.

Example 6CO₂ and ammonia cascade for 50 kW

A room at −40 °C needs 50 kW of cooling. The lower loop uses CO₂: it evaporates at −40 °C (saturated vapor out) and condenses in the exchanger to saturated liquid at −5 °C. The upper one uses ammonia: it evaporates in the exchanger at −10 °C (saturated vapor out) and condenses at 35 °C. Ideal compressions. Find the flows, the total power and the COP, and the entropy generated in the exchanger.
12345678Condenser (high loop)Valve (high loop)Compressor (high loop)Cascade heat exchangerCompressor (low loop)Valve (low loop)Evaporator (low loop)loop 2 · ammonialoop 1 · CO₂Q̇L = 50 kW−5 °C−10 °C

Solution

  1. CO₂ loop: (−40 °C) = 1004.5 kPa, = 435.32 kJ/kg; stream 3 has = −5 °C and : = 3045.9 kPa, = 188.05; compression to 3045.9 kPa, = 483.70 (33.54 °C); .
  2. CO₂ flow from the 50 kW: = 0.20220 kg/s; compressor 0.20220 × 48.38 = 9.783 kW; heat to the exchanger 0.20220 × (483.70 − 188.05) = 59.78 kW.
  3. Ammonia loop: (−10 °C) = 1431.33, (35 °C) = 346.94, ; compression to 1350.0 kPa, = 1654.35 (100.36 °C). The exchanger balance gives = 0.05513 kg/s.
  4. Upper compressor: 0.05513 × 223.02 = 12.295 kW. Total 22.078 kW; COP = 50/22.078 = 2.265 (Carnot between −40 and 35 °C: 233.15/75 = 3.109); 72.078 kW are rejected at 35 °C.
  5. Second law in the exchanger: = 0.00658 kW/K = 6.58 W/K > 0.
= 0.2022 kg/s, = 0.05513 kg/s, = 22.08 kW, COP = 2.265, = 6.58 W/K.

Solve it in Simuveliq

  1. «Load an example» → «Cascade refrigeration: CO₂ and ammonia». In «Fluid of each loop», «Loop 1» is CO₂ (streams 1–4) and «Loop 2» ammonia (5–8).
  2. Box: «Unknowns: 24 (P, h and ṁ of 8 streams) · equations: 26 (2 repeated mass balances in closed loops)», solved in 22 steps; two of them are «Stream 3: two data of its state… and no known pressure».
  3. Cards: COP 2.265 (Carnot 3.109), 50 kW, «Compressor power» 22.078 kW, «Heat rejected» 72.078 kW. In the stream table, = 0.2022 and 0.05513 kg/s; the cascade exchanger with TTD = 5 °C. There is one T-s per loop.

Example 7100 MW combined cycle

A gas turbine takes air at 100 kPa and 25 °C, with = 8, an 80 % compressor, 1100 °C at the turbine inlet and an 85 % turbine. Its gases pass through a heat-recovery steam generator and leave at 180 °C, raising steam at 8 MPa and 450 °C for an 85 % steam turbine that exhausts at 10 kPa (ideal pump). The total net power is 100 MW. Find the air and steam flows, the efficiency and that of each cycle on its own.
123456789AirCompressorCombustion chamberGas turbineHeat-recovery steam generatorExhaustSteam turbineCondenserPump219.96 MWrₚ = 8 · 80 %1100 °C · 85 %180 °C8 MPa · 450 °Cloop 1 · air (open)loop 2 · water (closed)

Solution

  1. Air side (air table): = 299.16; = 541.72, = 602.36 (321.56 °C); = 1484.02; = 842.19, = 938.46 (630.97 °C); = 455.91 kJ/kg.
  2. Water side: = 191.81; = 199.86; = 3273.3; = 2076.4, = 2255.9 kJ/kg ( = 0.8629: the simulator warns that it falls below ~88 %).
  3. 2 × 2 block: recovery boiler and net power = 100 000 kW. From the first, = 0.15701; in the second, (242.355 + 158.47) = 100 000: = 249.49 kg/s and = 39.171 kg/s.
  4. = 249.49 × (1484.02 − 602.36) = 219.96 MW and = 100/219.96 = 45.46 % (Carnot 76.77 %).
  5. Separately: the gas turbine gives 60.46 MW net (27.49 %); the steam cycle, 39.54 MW with the 120.39 MW recovered (32.84 %). In the recovery boiler the pinch is 54.1 °C, where the water starts to boil.
= 249.5 kg/s, = 39.17 kg/s, = 45.46 % (gas turbine 27.49 %, steam cycle 32.84 %).

Solve it in Simuveliq

  1. «Load an example» → «Combined gas–steam cycle, 100 MW». The air enters through «Inlet» (stream 1 with P and T) and leaves through «Outlet»; the sheet's «Net power (optional)» is 100000 kW.
  2. Box: «Unknowns: 27 (P, h and ṁ of 9 streams) · equations: 28 (1 repeated mass balance in closed loop)»: only the water loop is closed. In the step by step, the block of the recovery boiler and the sheet gives 249.49 and 39.171 kg/s.
  3. Cards: 45.46 % (Carnot 76.77 %), «Net power» 100 MW, «Heat in» 219.96 MW, «Heat out» 80.854 MW, back work 43.17 %, and the balance with «± flows» (the gases that leave). The device table, in kW, gives Ẇ = 136110 at the gas turbine, 75645 at the compressor and 39852 at the steam turbine. Try in the recovery boiler, «Hot side», «Outlet temperature» 90: the simulator warns that the temperatures cross inside.

Example 8Dual (Sabathé) engine with the air table

An ideal dual (Sabathé) cycle has a compression ratio r = 16. At the start of the compression the air is at 100 kPa and 300 K; in the combustion the pressure rises 1.4 times at constant volume and then the air receives heat at constant pressure up to 1900 K. With variable specific heats (air table), find every state, the heats, the net work, the efficiency and the mean effective pressure.
12345CompressionHeat at const. vHeat at const. PExpansionRejection at const. vwc we q23 q34 qout v = constP = constv = const100 kPa · 300 K×1.4 at const. v1900 Kr = 16 · air table5 states × 3 unknowns = 15

Solution

  1. Five processes and five states: 15 unknowns. Data: = 100 kPa and = 300 K, r = 16 and η = 100 % of the compression, = 1.4, = 1900 K and η = 100 % of the expansion; with the block equations and the basis = 1 kg/s there are 16, one of them a repeated mass balance: 15 = 15.
  2. State 1: = 0.86115 m³/kg, = 214.90 kJ/kg, = 216.11. Isentropic compression: = 13.507, so = 862.20 K and = 644.14 kJ/kg; = 0.053822 m³/kg and = 4598.4 kPa. Compression work: 644.14 − 214.90 = 429.24 kJ/kg.
  3. Constant volume: = 1.4 × 4598.4 = 6437.8 kPa and = 1.4 × 862.20 = 1207.08 K; = 940.45 kJ/kg, so = 296.31 kJ/kg.
  4. Constant pressure up to 1900 K: = 1900/1207.08 = 1.5740 and = 0.084718 m³/kg; = 2128.17 − 1286.94 = 841.23 kJ/kg, of which = 198.90 kJ/kg leave as boundary work.
  5. Isentropic expansion down to : = 1.1471 × 10.165 = 11.660, so = 907.16 K, = 681.48 kJ/kg and = 302.39 kPa. Expansion work: = 1582.78 − 681.48 = 901.30 kJ/kg.
  6. = 296.31 + 841.23 = 1137.54 kJ/kg; = 466.57 kJ/kg; = 1137.54 − 466.57 = 670.97 kJ/kg (= 198.90 + 901.30 − 429.24); = 670.97/1137.54 = 58.98 % (Carnot 84.21 %); MEP = 670.97/(0.86115 − 0.053822) = 831.10 kPa; back work ratio 429.24/1100.21 = 39.01 %.
= 58.98 % (Carnot 84.21 %), = 670.97 kJ/kg, MEP = 831.10 kPa, = 907.16 K, maximum pressure 6437.8 kPa.

Solve it in Simuveliq

  1. «Load an example» → «Dual (Sabathé) with the air table: r = 16, rₚ = 1.4, max. T 1900 K». From a «Blank sheet» it would be: in the palette, Piston engine → «Compression», «Heat at const. v», «Heat at const. P», «Expansion» and «Rejection at const. v», joined in that order and back to the first; «Fluid of each loop»: «Air (ideal gas, variable specific heats)»; in «Sheet», «Temperatures in» K.
  2. Data: stream 1 with «Pressure P» 100 and «Temperature T» 300; «Compression in the cylinder» with «Compression ratio» and «r = initial v / final v» 16; «Heat at constant volume» with «rₚ = final P / initial P (optional)» 1.4; stream 4 with «Temperature T» 1900. The expansion stays at «Set by the cycle». The box says «✓ Complete: … solved in 14 steps.»
  3. In the «Step by step» state 5 comes out in a single step: «its specific volume is set by Heat rejection at constant volume», and with it the isentrope. Cards: «Thermal efficiency» 58.98 % (Carnot 84.21 %), «Net work» 670.97 kJ/kg (expansion 1100.2 − compression 429.24), «Mean effective pressure» 831.1 kPa and «Maximum temperature and pressure» 1900 K with 6437.8 kPa. The P-v and T-s diagrams draw each process with its real curve.
  4. The same cycle is in «Thermodynamic cycles» (dual, «Dual with variable specific heats: r = 16, rₚ = 1.4, max. T 1900 K»), and its «Open in the cycle simulator» button builds this flowsheet with the same numbers.