Advanced cycles: regeneration, propulsion and heat pumps
The basic cycles topic solved the Rankine, the Brayton and the refrigerator. Power plants, aircraft and real machines go further: regeneration of the Rankine cycle with feedwater heaters, the Brayton cycle with intercooling, reheat and a regenerator, the turbojet, which turns the cycle into thrust, the heat pump and gas refrigeration. Every improvement answers the same question: at what temperature the heat enters and leaves. Here their balances are derived, we see when they pay off and they are solved in the simulator with real properties.
The common idea: at what temperature the heat enters
Any internally reversible cycle is equivalent to a Carnot cycle between the mean temperature at which it receives heat and the mean temperature at which it rejects it. Since , each mean temperature is the heat divided by the entropy change of the fluid in that exchange:
An example of what is lost: in an ideal Rankine cycle at 15 MPa, 600 °C and 10 kPa the water enters the boiler at 46.3 °C, and 41.6 % of the boiler heat is spent warming liquid up to 342.2 °C, the temperature at which it boils. That is why the boiler receives heat on average at only 286.7 °C, although the steam leaves at 600 °C. The improvements of this topic attack that kind of loss:
| Improvement | What it changes | Where |
|---|---|---|
| Feedwater heater | the water reaches the boiler hotter: rises | Rankine |
| Regenerator | the hot exhaust preheats the compressed air: rises and falls | Brayton, Ericsson, gas refrigeration |
| Intercooling | compresses colder air: less compression work | Brayton |
| Reheat between turbines | expands hotter gas: more turbine work | Brayton (and Rankine) |
| Nozzle | the enthalpy left over becomes velocity: the net work is kinetic energy | turbojet |
| Using instead of | the same refrigerator heats: | heat pump |
The basic cycles, the first law in each device, isentropic efficiencies and the air table with are in the cycles topic; here they are taken as known:
Regenerative Rankine: the open feedwater heater
The idea is to heat the feedwater with steam extracted from the turbine at an intermediate pressure , after that steam has already given part of its work. In the open heater (mixing type) the extracted steam and the water mix and leave as saturated liquid at ; mixing at high temperature also drives out the dissolved air, which is why power plants call it a deaerator. Since everything entering the heater must be at its pressure, one pump is needed before it (from the condenser to ) and another after it (from to the boiler).
Everything is computed per kg of steam through the boiler. The heater is insulated and has no shafts, so the enthalpy that enters is the one that leaves; that gives the extracted fraction:
Each device is multiplied by the flow through it: the high-pressure part of the turbine carries all the steam, the low-pressure part and pump 1 only :
Why does it help? The fraction gives its latent heat to the feedwater instead of to the condenser, and the boiler no longer heats cold liquid: in the figure its line starts at 4, at 190.0 °C, not at 46.3 °C. The mean boiler temperature rises from 286.7 °C to 347.2 °C and the efficiency, from 43.03 % to 46.31 %.
Then why does it not reach %? Because mixing in the heater is irreversible: steam at 217.1 °C mixes with water at 46 °C and entropy is generated, kJ/kg·K per kg of steam. The condenser has to remove that extra entropy: against the kJ/kg·K that enter in the boiler. With more heaters each bridges a smaller temperature difference, less entropy is generated and the cycle approaches Carnot between and ; that is why large plants use several.
The closed feedwater heater and the trap
In the closed heater (surface type, like a shell-and-tube exchanger) the streams do not mix: the feedwater flows through the tubes at boiler pressure and the extracted steam condenses outside at . That is why one pump is enough. In the ideal case the water leaves at the saturation temperature of the extracted steam, , and the condensate (the drain) leaves as saturated liquid at . The drain goes through a trap, a valve that only lets liquid through, and is throttled to a lower pressure: in the simulator, to the condenser; in power plants it is also sent to the next lower-pressure heater or pumped forward into the feedwater line.
The heater balance equates what the extracted steam gives, from 5 down to saturated liquid at 7, with what the water receives, from 2 to 3. The drain reaches the condenser with its enthalpy:
State 3 is compressed liquid at the boiler pressure and at ; its enthalpy is almost that of saturated liquid at that temperature, . With the same data as the open heater:
| 15 MPa, 600 °C, 10 kPa, ideal | No heater | Open at 1.2 MPa | Closed at 1.2 MPa |
|---|---|---|---|
| Extracted steam | — | 0.2271 | 0.2903 |
| Boiler inlet | 46.3 °C | 190.0 °C | 188.0 °C |
| (kJ/kg) | 1467.89 | 1299.06 | 1252.06 |
| (kJ/kg) | 15.10 | 16.58 (two pumps) | 15.10 |
| (kJ/kg) | 3376.23 | 2769.16 | 2778.11 |
| (kJ/kg) | 1923.43 | 1486.68 | 1541.15 |
| η | 43.03 % | 46.31 % | 44.53 % |
The closed heater does worse here for two reasons. The extracted steam only gives its heat down to saturated liquid at 188 °C, so more is needed ( against 0.2271) and less steam goes through the low-pressure part of the turbine. And the drain, with kJ/kg, is throttled to the condenser and dumps kJ/kg into it. In exchange, each closed heater needs no pump of its own, it can work at high pressures and the streams do not contaminate each other; power plants combine several closed heaters with one open heater that also deaerates.
Which extraction pressure and from which turbine
With a very low extraction pressure the heater hardly warms the water; with a very high one the extracted steam has given almost no work. Between the two extremes there is an optimum, which the simulator lets you find by changing the «Extraction pressure»:
The optimum of the open heater, 46.32 % near 1.34 MPa, leaves the water at 193.1 °C, almost halfway between condensation (45.81 °C) and boiling in the boiler (342.16 °C): °C. That is the rule of thumb: with one heater, heat the water halfway; with heaters, split the temperature rise into equal parts. The maximum is also flat: between 0.85 and 2 MPa the efficiency changes by less than 0.1 points, and the pressure that suits the turbine is chosen.
With reheat: where does the extraction come from?
If the cycle also reheats, the extraction comes from the high- or the low-pressure turbine depending on its pressure, and that changes which flow goes through the reheater. The simulator decides it by itself. In the table, is the turbine inlet, the boiler inlet, the high-pressure turbine exit and the reheater exit:
| Case | Where the extracted steam comes from | Heat received per kg of boiler steam |
|---|---|---|
| from the high-pressure turbine, before reheat | ||
| from the high-pressure turbine exit: part to the heater and the rest to the reheater | the same as above | |
| from the low-pressure turbine, already reheated |
In example 3 (reheat at 4 MPa, 88 % turbines) the extraction at 500 kPa comes from the low-pressure turbine and gives 43.36 %; without a heater the same cycle gives 40.05 %, with the extraction at 4 MPa 42.30 % and at 6 MPa, now in the high-pressure turbine, 41.95 %.
Brayton with intercooling and reheat
In reversible steady flow the compression work is , and in an ideal gas : raising the pressure by the same ratio costs less if the gas is cold. That is why the air is compressed in two stages with an intercooler between them that brings it back to . The other way round in the expansion: between two turbines a reheater (another combustor: the gases still have plenty of oxygen) brings the gas back to and the second turbine gives more work.
Which intermediate pressure ? With the cold-air standard and intercooling back to , the work of the two compressors is a sum of two powers; differentiating with respect to and setting it to zero gives two stages with the same ratio, and therefore the same work:
The same holds for the turbines: with reheat back to , gives the largest work. With variable specific heats the two stages also come out equal, because each starts at the same temperature with the same ratio. With more stages the process looks more and more like an isotherm:
Without a regenerator, the efficiency falls
Two stages raise the net work but, without a regenerator, lower the efficiency: the air leaves the high-pressure compressor colder (403.3 K instead of 539.8 K), so the combustor starts heating at a lower temperature, and the exhaust leaves hotter (1006.3 K instead of 770.3 K). falls and rises. That is exactly what a regenerator fixes: the hot exhaust heats the cold compressor air, and all the external heat enters close to . With the air table, , 300 K and 1300 K, ideal:
| Ideal, air table | One stage | Two stages | Two stages + ideal regenerator | One stage + ideal regenerator |
|---|---|---|---|---|
| (kJ/kg) | 362.36 | 476.73 | 476.73 | 362.36 |
| Back work | 40.24 % | 30.42 % | 30.42 % | 40.24 % |
| 873.8 K | 848.9 K | 1147.9 K | — | |
| 502.0 K | 545.5 K | 349.2 K | — | |
| η (air table) | 42.55 % | 35.73 % | 69.58 % | 59.76 % |
| η (cold air, ) | 44.8 % | 37.4 % | 68.9 % | 58.2 % |
With the cold-air standard everything stays in formulas. With per stage and an ideal regenerator, the external heat is exactly the turbine work, because the air reaches the combustor at the turbine exit temperature; with equal stages:
Toward the Ericsson cycle
With infinitely many stages the compression and the expansion become isotherms at and , and with an ideal regenerator all the external heat enters at and leaves at : it is the Ericsson cycle, with the Carnot efficiency. In the simulator it is under «Gas turbines and propulsion» → «Ericsson»: the example at 300 K and 1200 K with an ideal regenerator gives 75 %, equal to Carnot. In practice two or three stages are used, because each one adds heat exchangers, pressure losses and cost. The Stirling and Ericsson cycles are explained in detail in the engines topic:
The turbojet
A turbojet is a gas turbine in which the turbine only drives the compressor. The enthalpy left in the gases becomes velocity in a nozzle, and the reaction of that jet pushes the aircraft. It is analyzed with the air standard, combustion as a heat at constant pressure and the fuel mass neglected:
- Diffuser 1 → 2: it slows the air down to a negligible velocity and its kinetic energy becomes enthalpy (ram compression): . If isentropic, .
- Compressor 2 → 3 and combustor 3 → 4: as in the Brayton cycle, and .
- Turbine 4 → 5: it gives exactly the compressor work, ; that gives , and the exit pressure follows from the isentropic expansion with that work.
- Nozzle 5 → 6: it expands to the outside pressure and the enthalpy drop becomes velocity: , with in J/kg.
Thrust and efficiencies
The thrust comes from Newton’s second law applied to a control volume around the engine: the air enters at and leaves at , the pressure is all around the boundary (the nozzle expands to ) and the fuel flow is small compared with the air flow. The force the engine exerts on the air, and its reaction on the aircraft, is the change of momentum per second:
is the specific thrust, in N·s/kg (= m/s): it measures how much each kg/s of air pushes. The propulsive power is what the aircraft receives, . Per kg of air the engine gives the jet of kinetic energy, which is the net work of the cycle (turbine and compressor cancel out). That gives the three efficiencies:
The propulsive efficiency holds the big design compromise: a jet much faster than the aircraft gives a lot of thrust per kg of air, but leaves almost all its kinetic energy in the atmosphere (low ). If approaches , tends to 1, but each kg pushes little and a huge amount of air has to be moved. That is why airliners use turbofans, which accelerate a lot of air a little with a fan, and turboprops; the pure turbojet is left for very fast flight.
Static thrust: with the aircraft at rest (take-off, test stand) , the thrust is and there is no propulsive power, because nothing moves: does not mean a bad engine, only that the propulsive efficiency makes sense in flight. The three examples of the simulator:
| Example | (m/s) | (m/s) | (N·s/kg) | (kN) | |||
|---|---|---|---|---|---|---|---|
| ideal, 45 kg/s (jt-ideal) | 260 | 1005.8 | 745.8 | 33.56 | 41.08 % | 54.73 % | 22.49 % |
| real, 85–97 % (jt-real) | 260 | 958.0 | 698.0 | 31.41 | 42.69 % | 46.04 % | 19.66 % |
| on the ground, 20 kg/s (jt-static) | 0 | 850.9 | 850.9 | 17.02 | 0 | 41.33 % | 0 |
The heat pump
A heat pump is the same vapor-compression cycle as a refrigerator, but what matters is the heat the condenser delivers indoors: the evaporator takes heat from outdoor air (or the ground, or water) and the compressor «lifts» its temperature. The first law over the whole cycle gives the relation between the two COPs:
So the COP of a heat pump is always above 1: even a very poor one delivers at least the electricity it uses, and a good one adds the heat taken from outdoors. In example 8, 12 kW are delivered with 3.007 kW of electricity; the other 8.993 kW come from the outdoor air, which has to be warmer than −5 °C to heat the vapor to that temperature. An electric resistance would need the full 12 kW. For the Carnot limit the simulator uses the refrigerant temperatures that bound the cycle: (the coldest in the condenser) and (the warmest in the evaporator).
When the outdoor air gets colder
For heat to flow, the refrigerant has to evaporate colder than the outdoor air. A colder day forces a lower evaporating temperature, and that makes three things worse: the pressure ratio and the work per kg grow, the COP falls (like the Carnot one, which depends on ), and the vapor entering the compressor is less dense. The last one is key: a compressor moves a fixed volume per second, so the heat it delivers is proportional to , the heat per m³ of vapor drawn in. The heat pump gives less heat just when the house needs more:
That is why air-source heat pumps are sized for a design day and carry a backup resistance for the coldest days. Below a few degrees the moisture of the air freezes on the outdoor coil, and the machine reverses the cycle for a moment (with a four-way valve) to defrost it; the same valve turns it into an air conditioner in summer. Ground-source heat pumps take the heat from the ground, which is at a steadier temperature, and so they evaporate warmer.
Choice of refrigerant
The same ideal cycle (0 °C and 40 °C) with two refrigerants of the simulator tables:
| Ideal, 0 °C and 40 °C | R-134a | R-410A |
|---|---|---|
| Evaporator pressure | 292.8 kPa | 798.7 kPa |
| Condenser pressure | 1016.6 kPa | 2420.7 kPa |
| Pressure ratio | 3.47 | 3.03 |
| Compressor discharge | 44.49 °C | 57.17 °C |
| (Carnot 7.829) | 6.494 | 6.131 |
| (heat per m³ drawn in) | 2425 kJ/m³ | 5670 kJ/m³ |
| Critical temperature | 101.06 °C | 71.34 °C |
- Pressures: in the evaporator, better above atmospheric (otherwise air leaks in); in the condenser, not so high that they make piping and compressor expensive.
- Volumetric capacity: R-410A delivers 2.3 times more heat per m³ drawn in than R-134a, so for the same power the compressor is much smaller. That is why it is used in air conditioners and heat pumps.
- Critical temperature: it must be well above the condensing one. R-410A condenses at 40 °C only 31 °C from its critical point, the dome is narrow and a large part of is cooling superheated vapor: its COP comes out lower than that of R-134a.
- Low discharge temperature (the compressor oil), safety (toxicity, as with ammonia; flammability, as with hydrocarbons) and environment: ozone depletion and global warming potential, which regulations limit more and more.
Gas refrigeration: the reverse Brayton cycle
Reversing the Brayton cycle gives a refrigerator that uses a gas (almost always air) without phase change: 1 → 2 a compressor raises the pressure and temperature; 2 → 3 the gas rejects heat to the surroundings at constant pressure; 3 → 4 it expands in a turbine, which cools it a lot and returns work to the compressor shaft; 4 → 1 it takes heat from the cold space. Why a turbine and not a valve? Because in an ideal gas depends only on : a valve () would not cool it at all.
The last one follows with constant and : and , so . Lowering raises the COP, but the gas leaves the turbine less cold and each kg takes less heat.
Why such a low COP? The mean temperatures explain it: K and K, and against the Carnot 5.667. Besides, without phase change each kg takes little heat (53.38 kJ/kg, against 143.7 kJ/kg for the ideal R-134a cycle between 0.14 and 0.8 MPa of the cycles topic), and the net work is the difference of two large works: with an 85 % compressor and an 88 % turbine (and variable specific heats) the COP falls from 2.058 to 0.6954.
With a regenerator: very low temperatures
A regenerator uses the cold gas leaving the refrigerated space to cool the high-pressure gas further before the turbine. The turbine starts colder and ends much colder: with and 80 % and 85 % machines, the simulator example reaches 178.2 K (−94.96 °C); without the regenerator, the same data reach 222.4 K. That is how gases are liquefied and cryogenic temperatures are reached, with more stages and exchangers.
| Vapor compression | Gas cycle | |
|---|---|---|
| Fluid | refrigerant that evaporates and condenses | air or another gas, without phase change |
| Expansion | valve (constant ) | turbine (recovers work) |
| Heat per kg | large (latent heat) | small: large flows |
| COP | high, close to Carnot | low |
| Where it is used | refrigerators, air conditioning, heat pumps | aircraft cabins, gas liquefaction, very low temperatures |
In aircraft the refrigerant is the air itself: compressed air is taken from the engine, cooled with outside air, expanded in a turbine and sent cold into the cabin (an open cycle). The equipment is light and carries no toxic or flammable refrigerants, and that matters more than the COP.
Using the simulator
It is in Engineering → Thermodynamic cycles; the results are recomputed as you type. The panel starts with «Which cycle do you want to analyze?» and four families: Steam power, Gas turbines and propulsion, Piston engines and Refrigeration and heat pumps. Below it, the «Cycle» row shows the cycles of that family (Brayton, Turbojet, Ericsson; Refrigerator, Heat pump, Gas refrigeration), and each family remembers the last one you used. All in SI: absolute pressures in kPa, °C in Rankine and vapor refrigeration, kelvin in the gas cycles.
- Rankine with a heater: in the «Feedwater heater» section choose «None», «Open» or «Closed»; «Extraction pressure» (kPa) appears, and the first time it proposes the geometric mean of the boiler and condenser pressures. It combines with «With reheat», and the simulator decides which turbine the extraction comes from. New cards: «Extracted steam» ( and the heater pressure) and, with «Net power (optional)», «Steam flow» with the extraction in kg/s. The states table names «Extraction to the heater», «Drain: saturated liquid at the heater pressure» and «Drain after the trap (to the condenser, same h)».
- Two-stage Brayton: in «Intercooling and reheat» tick «Two stages of compression and of expansion»; an empty «Intermediate pressure (optional)» uses , and the field becomes «Turbine inlets». Cards «Intermediate pressure», «Compressor exits» and «Turbine exits». «Regenerator (effectiveness)» works the same: if the low-pressure turbine exit is not hotter than the high-pressure compressor exit, it warns and does not use it.
- Turbojet: «Air model» («Variable specific heats» or «Cold-air standard», with k and cₚ); «Flight conditions»: «Air temperature T₁» (K), «Air pressure P₁», «Flight speed» (0 = test stand) and «Air flow (optional)»; «Engine and efficiencies»: «Compressor pressure ratio», «Turbine inlet T₄», «Compressor (isentropic)», «Turbine (isentropic)», «Diffuser (optional)» and «Nozzle (optional)» (empty or 100 % = ideal). Cards: «Exit velocity», «Specific thrust», «Thrust» (with the flow; without it, «Propulsive power» per kg), «Propulsive efficiency», «Thermal efficiency», «Overall efficiency», «Heat in» and «Compressor work». The states table carries the velocity.
- Heat pump: the «Heat pump» button uses the same fields as the refrigerator, but the capacity is «Heating capacity» (, kW). Cards: «Heat-pump COP» (with Carnot), «Heat delivered», «Compressor work» (with ), «Heat taken from outdoors», «COP as a refrigerator», «Quality after the valve» and «Refrigerant flow». Its examples list only has heat pumps.
- Gas refrigeration: «Temperatures and pressures»: «Compressor inlet T₁ (leaves the cold space)» (with a regenerator, «Leaves the cold space T₆»), «Low pressure P₁», «Pressure ratio rₚ» and «After rejecting heat T₃»; «Efficiencies and capacity»: «Compressor (isentropic)», «Turbine (isentropic)», «Regenerator (effectiveness)» (0 % = none) and «Cooling capacity». Cards: «Refrigeration COP», «Refrigerating effect», «Net work in», «Lowest temperature», «Heat rejected» and «Gas flow».
- In all of them: «Examples» → «Load an example»; the Diagrams card draws the T-s (with the real dome for water and refrigerants; in the gas cycles, the isobars of the air table or of cold air; in green, the heater or the regenerator); Cycle states; Step by step with each balance and the Detailed solution (PDF) button, which explains each state and each equation. The warnings (⚠) point out low quality at the turbine exit, useless regenerators or very hot discharges, and an impossible value gives a message that names the field.
Rankine, Brayton and refrigeration also have the «Cycle simulator» section with the Open in the cycle simulator button: it opens the same cycle as a flowsheet, with its devices and streams, to add more heaters, another destination for the drain or a second loop (cascade refrigeration, combined cycle). How to set up such a cycle is in its topic:
Common mistakes
- Forgetting the in the low-pressure turbine, pump 1, the condenser or, if the extraction comes first, the reheater.
- Adding the heat of the extracted steam to the boiler heat: the heater is internal, it receives no heat from outside.
- Open heater: taking its exit at boiler pressure (it is saturated liquid at ) or forgetting the second pump.
- Closed heater: confusing the feedwater (boiler pressure, ) with the drain (saturated liquid at ), or taking a different before and after the trap.
- Expecting two stages without a regenerator to raise the efficiency: they raise the work, but the efficiency falls.
- Taking the intermediate pressure as the arithmetic mean instead of the geometric , or using the overall in each stage.
- Turbojet: looking for net work from the turbine (it only drives the compressor), forgetting the diffuser compression or using as the thrust in flight.
- Mixing J/kg and kJ/kg with .
- Heat pump: using instead of , or °C in the Carnot limit.
- Gas refrigeration: dividing by the compressor work instead of the net .
Worked examples
Example 1Regenerative Rankine with an open feedwater heater
Solution
- State 1 (10 kPa, ): °C, kJ/kg, m³/kg, kJ/kg·K. Pump 1: kJ/kg, kJ/kg.
- State 3, saturated liquid at 1.2 MPa: °C, kJ/kg, m³/kg. Pump 2: kJ/kg (the equation of state, which accounts for the liquid being compressed, gives 15.65); kJ/kg.
- State 5 (15 MPa, 600 °C): kJ/kg, kJ/kg·K. State 6 (1.2 MPa, ): since , it is superheated vapor, kJ/kg (217.1 °C).
- State 7 (10 kPa, ): and kJ/kg.
- Heater: .
- kJ/kg; kJ/kg; kJ/kg.
- kJ/kg and kJ/kg (check: ). %: 3.3 points more than without a heater.
Solve it in Simuveliq
- Steam power → Rankine, «Load an example» → Open feedwater heater: 15 MPa, 600 °C, 10 kPa, extraction at 1.2 MPa. By hand: 15000 kPa, 600 °C, 10 kPa, efficiencies 100 % and in «Feedwater heater» press «Open» and type 1200 in «Extraction pressure».
- Cards: «Thermal efficiency» 46.31 % (Carnot 63.47 %), «Net work» 1282 kJ/kg, «Heat in» 2769, «Extracted steam» y = 0.2271 and «Exit quality» 80.41 %, with the erosion warning. Press «None»: 43.03 %; change the extraction pressure to follow the curve of the figure.
Example 2The same cycle with a closed feedwater heater
Solution
- States 1, 4, 5 and 6 are those of example 1 (there 1, 5, 6 and 7). A single pump to 15 MPa: kJ/kg (equation of state: 15.10), kJ/kg.
- State 3: compressed liquid at 15 MPa and °C: kJ/kg (the approximation is off by 0.8 %).
- Drain 7: saturated liquid at 1.2 MPa, kJ/kg. The trap does not change : kJ/kg, and at 10 kPa it is a mixture with .
- Heater: .
- kJ/kg; kJ/kg; kJ/kg.
- kJ/kg; %.
Solve it in Simuveliq
- The button loads Closed feedwater heater: the same data, drain to the condenser (or press «Closed» on example 1).
- Cards: 44.53 %, «Net work» 1237 kJ/kg, «Extracted steam» y = 0.2903 «to the closed heater (1200 kPa)». The table describes state 3 as «Feedwater at 188 °C (closed heater exit)» and state 8 as a mixture of quality 0.2536; the diagram draws the drain in green dashes.
Example 3Plant with reheat, an open heater and real turbines
Solution
- Pumps: kJ/kg (10 → 500 kPa), ; state 3, saturated liquid at 500 kPa (151.83 °C), ; kJ/kg, kJ/kg.
- High-pressure turbine: , ; at 4 MPa , kJ/kg (396.2 °C).
- Reheated at 4 MPa and 600 °C: , . Since 500 kPa < 4 MPa, the extraction comes from the low-pressure turbine: , kJ/kg (313.7 °C).
- Last section from 8: gives at 10 kPa and ; kJ/kg, .
- .
- ; ; kJ/kg.
- All the steam goes through the reheater: kJ/kg and %.
- kg/s, of which kg/s go to the heater; MW.
Solve it in Simuveliq
- The button loads Reheat and open heater, 88 % turbines, 150 MW: 15000 kPa, 600 °C, 10 kPa, «Turbine (isentropic)» 88, «Pump (isentropic)» 90, «Net power (optional)» 150, «With reheat» with 4000 kPa and 600 °C, «Open» heater at 500 kPa.
- Cards: 43.36 %, «Extracted steam» y = 0.1544, «Exit quality» 95.06 % and «Steam flow» 101.9 kg/s with «extraction 15.73 kg/s» and 345.9 MW. Type 6000 in «Extraction pressure»: the extraction comes from the high-pressure turbine, the step by step multiplies the reheat by (1 − y) and η falls to 41.95 %.
Example 4Two-stage Brayton: without and with a regenerator
Solution
- kPa: each stage with ratio .
- Low-pressure compressor: at 300 K, kJ/kg and ; gives K and kJ/kg. The intercooler goes back to 300 K and the high-pressure compressor repeats the stage ( K): kJ/kg.
- High-pressure turbine: at 1300 K, kJ/kg and ; gives K and kJ/kg. Reheated to 1300 K, the low-pressure one repeats: kJ/kg.
- kJ/kg; kJ/kg; % and %.
- Against one stage: 32 % more work, but 6.8 points less efficiency, because the air enters the combustor at 403.3 K instead of 539.8 K, and the exhaust leaves at 1006.3 K instead of 770.3 K.
- With an ideal regenerator the exhaust heats the compressed air from 403.3 K to 1006.3 K, and the external heat becomes kJ/kg : % (one stage with an ideal regenerator: 59.76 %; Carnot: 76.92 %).
Solve it in Simuveliq
- Gas turbines and propulsion → Brayton, «Load an example» → Two stages with intercooling and reheat: rₚ = 8 (or, on the ideal Brayton, tick «Two stages of compression and of expansion»).
- Cards: 35.73 % (Carnot 76.92 %), «Net work» 476.7 kJ/kg, «Intermediate pressure» 282.8 kPa «√(P₁P₂): the one of largest work», «Compressor exits» 403.3 · 403.3 K, «Turbine exits» 1006 · 1006 K, back work 30.42 %. Type 100 in «Regenerator (effectiveness)» (or load Two stages and an ideal regenerator (100 %)): 69.58 %, and the states are now numbered 1 to 10.
Example 5Real two-stage gas turbine with a regenerator, 50 MW
Solution
- kPa and ratio per stage .
- Compressors: gives K and kJ/kg; kJ/kg (449.4 K). Both stages are equal: kJ/kg.
- Turbines: at 1400 K kJ/kg and ; gives K and ; kJ/kg (1078.3 K). kJ/kg.
- The low-pressure turbine exit (1078.3 K) is hotter than the high-pressure compressor exit (449.4 K): the regenerator helps. kJ/kg (928.3 K) and kJ/kg (614.6 K).
- kJ/kg; kJ/kg; %.
- kg/s and MW.
- With the same data: without the regenerator 31.64 %; in a single stage with the 75 % regenerator, 41.40 % and 171.2 kg/s; in a single stage without a regenerator, 34.37 %.
Solve it in Simuveliq
- The button loads Two real stages: 85 % and 88 %, 75 % regenerator, 50 MW: «Variable specific heats», 300 K, 100 kPa, rₚ = 12, «Turbine inlets» 1400 K, 85, 88, 75 and «Net power (optional)» 50.
- Cards: 49.11 %, «Intermediate pressure» 346.4 kPa, «Compressor exits» 449.4 · 449.4 K, «Turbine exits» 1078 · 1078 K, back work 39.81 % and «Air flow» 109.5 kg/s with 101.8 MW. Set the regenerator to 0 (31.64 %) or untick «Two stages…» (41.4 %) to compare.
Example 6Ideal turbojet in flight
Solution
- Diffuser: J/kg kJ/kg; K and kPa.
- Compressor: kPa, K; kJ/kg.
- Combustor: kJ/kg.
- Turbine (): K and kPa.
- Nozzle: K and m/s.
- N·s/kg; kN; kW.
- %; %; %.
Solve it in Simuveliq
- Gas turbines and propulsion → Turbojet, «Load an example» → Ideal turbojet: 260 m/s at −40 °C and 34.5 kPa, rₚ = 10.
- Cards: «Exit velocity» 1006 m/s, «Specific thrust» 745.8 N·s/kg, «Thrust» 33.56 kN, «Propulsive efficiency» 41.08 %, «Thermal efficiency» 54.73 %, «Overall efficiency» 22.49 % and «Compressor work» 249.5 kJ/kg «= turbine work». Change the «Flight speed» to follow the thrust figure. With Real turbojet: components at 85–97 %, variable specific heats: 958 m/s, 31.41 kN and 19.66 %.
Example 7Static thrust on a test stand
Solution
- At rest there is no compression in the diffuser: K, kJ/kg, .
- Compressor: gives K and ; kJ/kg (630.7 K) and kJ/kg.
- kJ/kg.
- Turbine: kJ/kg (1102.7 K). The exit pressure follows from the ideal expansion that would give that work: , K, and kPa.
- Ideal nozzle to 101.325 kPa: gives K and ; m/s.
- kN; MW; % and because .
Solve it in Simuveliq
- The button loads Ground test stand: aircraft at rest, 20 kg/s: «Variable specific heats», 288.15 K, 101.325 kPa, «Flight speed» 0, 12, 1400 K, 85 and 88 and «Air flow (optional)» 20.
- Cards: «Exit velocity» 850.9 m/s, «Thrust» 17.02 kN, «Propulsive efficiency» 0 %, «Thermal efficiency» 41.33 % and «Heat in» 876 kJ/kg with 17.52 MW. The states table gives at each state; in the step by step the turbine computes and as here.
Example 812 kW R-134a heat pump
Solution
- Saturation: kPa and kPa.
- State 1: 200.6 kPa and −5 °C, superheated vapor: kJ/kg and kJ/kg·K.
- Compressor: kJ/kg at 1159.9 kPa with ; kJ/kg, kJ/kg and °C.
- State 3: 1159.9 kPa and 40 °C, compressed liquid: kJ/kg (almost ) , and after the valve .
- and kJ/kg; .
- kg/s; kW and kW, which come from the outdoor air.
- Carnot between K and K: ; the machine reaches 57 % of it. An electric resistance would use 12 kW: the heat pump saves three quarters.
Solve it in Simuveliq
- Refrigeration and heat pumps → Heat pump, «Load an example» → R-134a heat pump: −10 °C and 45 °C, 12 kW of heating (R-134a, «By temperatures», 80 %, «Heating capacity» 12, 5 and 5).
- Cards: «Heat-pump COP» 3.991 (Carnot 6.959), «Heat delivered» 187.5 kJ/kg, «Compressor work» 46.99 kJ/kg with T₂ = 64.9 °C, «COP as a refrigerator» 2.991 and «Refrigerant flow» 0.06399 kg/s with 12, 3.007 and 8.993 kW. Lower the «Evaporating temperature» to see the COP fall; Ideal R-410A heat pump: 0 °C and 40 °C, 10 kW gives 6.131.
Example 9Ideal gas refrigeration
Solution
- : K and K.
- kJ/kg, kJ/kg and kJ/kg: the turbine returns 79 % of the compressor work.
- kJ/kg and , equal to .
- kg/s, kW and kW.
- Carnot between 255 and 300 K: ; the cycle gives 36 % of it. With an 85 % compressor, an 88 % turbine and variable specific heats (15 kW) the COP falls to 0.6954 and the turbine exit rises to 213.6 K.
Solve it in Simuveliq
- Refrigeration and heat pumps → Gas refrigeration, «Load an example» → Ideal gas refrigeration: −18 °C and 27 °C, rₚ = 4, 10 kW.
- Cards: «Refrigeration COP» 2.058 (Carnot 5.667), «Refrigerating effect» 53.38 kJ/kg, «Net work in» 25.94 kJ/kg (compressor 124.5 − turbine 98.61), «Lowest temperature» 201.9 K and «Gas flow» 0.1873 kg/s with 10, 4.86 and 14.86 kW. Load 85 % compressor, 88 % turbine, variable specific heats, 15 kW (0.6954) and With a 90 % regenerator: −33 °C and 35 °C, which reaches 178.2 K.