Simuveliq

R-32 saturation table by pressure

This table gives saturation temperature and properties of saturated liquid and vapor for each pressure. Above you can use it interactively (switch units with SI/US, pick the pressure or go to the calculator for any point with step-by-step interpolation). Reference state: ASHRAE: h = 0 and s = 0 for saturated liquid at −40 °C (−40 °F).

The table as text, SI units
Specific volume [m³/kg]Internal energy [kJ/kg]Enthalpy [kJ/kg]Entropy [kJ/kg·K]
P [kPa]Tsat [°C]vfvgufufgughfhfghgsfsfgsg
5−96.9300.00075115.5997−89.615398.65309.04−89.611426.64337.04−0.439682.42111.9814
6−94.7920.00075424.7194−86.282396.35310.07−86.277424.66338.39−0.420882.38101.9601
8−91.2930.00075923.6039−80.829392.58311.75−80.823421.41340.58−0.390612.31721.9266
10−88.4670.00076332.9241−76.425389.52313.10−76.418418.76342.34−0.366582.26741.9009
15−83.0620.00077152.0006−67.999383.64315.64−67.988413.64345.65−0.321612.17601.8544
20−78.9970.00077771.5286−61.659379.18317.52−61.644409.74348.10−0.288612.11041.8218
25−75.7030.00078291.2407−56.516375.54319.03−56.496406.54350.05−0.262332.05901.7967
30−72.9130.00078741.0463−52.156372.44320.29−52.132403.81351.67−0.240412.01661.7762
40−68.3200.00079500.79946−44.967367.29322.32−44.935399.24354.30−0.204911.94911.7442
50−64.5850.00080130.64884−39.110363.06323.94−39.070395.46356.39−0.176571.89611.7195
60−61.4150.00080680.54704−34.128359.43325.30−34.080392.20358.12−0.152871.85231.6994
80−56.1800.00081610.41778−25.880353.36327.48−25.814386.72360.90−0.114381.78241.6680
100−51.9090.00082400.33885−19.126348.33329.21−19.044382.14363.09−0.0835501.72721.6437
150−43.6350.00084000.23135−5.9673338.39332.42−5.8413372.96367.12−0.0251511.62501.5998
200−37.3230.00085290.176254.1485330.58334.734.3191365.66369.980.0183371.55061.5689
250−32.1500.00086410.1425812.497324.03336.5312.713359.46372.180.0533671.49161.5449
300−27.7310.00087400.1198119.677318.32338.0019.939354.00373.940.0828981.44241.5253
400−20.3780.00089150.09087331.729308.54340.2732.085344.53376.620.131311.36301.4943
500−14.3310.00090680.07318641.754300.21341.9742.207336.35378.560.170531.29961.4701
600−9.15030.00092080.06122050.434292.85343.2950.986329.03380.020.203761.24631.4501
800−0.506130.00094610.04601165.134280.04345.1765.891316.09381.980.258611.15931.4180
10006.62400.00096910.03671377.494268.88346.3878.463304.63383.090.303441.08881.3923
150020.6190.0010220.024032102.53245.07347.60104.06279.59383.640.390950.951721.3427
200031.4310.0010710.017512122.78224.39347.17124.92257.27382.190.458930.844681.3036
250040.3580.0011220.013507140.33205.23345.56143.14236.19379.330.516110.753391.2695
300048.0160.0011760.010773156.23186.70342.93159.76215.49375.250.566670.670961.2376
400060.7680.0013030.0072068185.53148.87334.40190.74172.49363.220.657440.516551.1740
500071.1830.0015010.0048191215.27103.68318.95222.77120.27343.040.747730.349281.0970
The table as text, English units
Specific volume [ft³/lbm]Internal energy [Btu/lbm]Enthalpy [Btu/lbm]Entropy [Btu/lbm·R]
P [psia]Tsat [°F]vfvgufufgughfhfghgsfsfgsg
0.8−140.410.0120681.806−37.761170.86133.10−37.759182.97145.21−0.102610.573110.47051
1−135.620.0121266.360−35.975169.63133.65−35.973181.91145.93−0.0970550.561340.46429
1.5−126.460.0122445.387−32.566167.26134.70−32.562179.86147.29−0.0866800.539770.45309
2−119.580.0123334.672−30.007165.48135.47−30.002178.30148.30−0.0790780.524290.44522
2.5−114.020.0124128.140−27.934164.02136.09−27.929177.04149.11−0.0730340.512180.43915
3−109.320.0124723.728−26.181162.79136.61−26.174175.95149.78−0.0679950.502220.43422
4−101.580.0125818.131−23.296160.74137.45−23.286174.15150.87−0.0598490.486340.42649
5−95.3020.0126714.717−20.951159.07138.12−20.939172.67151.73−0.0533570.473900.42054
6−89.9800.0127512.409−18.960157.64138.68−18.945171.40152.46−0.0479320.463640.41570
8−81.2050.012889.4809−15.671155.25139.58−15.652169.27153.62−0.0391400.447260.40812
10−74.0600.012997.6930−12.986153.29140.30−12.961167.50154.54−0.0321100.434380.40227
15−60.2480.013225.2589−7.7727149.42141.65−7.7360163.98156.25−0.0188270.410540.39172
20−49.7380.013404.0118−3.7827146.41142.63−3.7332161.21157.47−0.00896570.393250.38428
25−41.1410.013553.2499−0.50135143.90143.39−0.43865158.87158.43−0.00104230.379580.37854
30−33.8070.013692.73462.3121141.71144.032.3880156.82159.210.00562320.368240.37386
40−21.6270.013932.07997.0170138.00145.027.1201153.30160.420.0165190.349960.36648
50−11.6280.014131.679810.913134.88145.7911.044150.29161.330.0253180.335430.36075
60−3.07460.014321.409114.274132.13146.4014.433147.61162.050.0327510.323290.35604
8011.1760.014641.065119.936127.39147.3320.152142.94163.100.0449710.303590.34856
10022.9140.014940.8548224.667123.33147.9924.943138.87163.810.0549050.287760.34267
15045.9190.015580.5681934.152114.83148.9834.585130.17164.750.0741350.257460.33159
20063.6780.016170.4210941.713107.68149.3942.311122.66164.970.0888670.234380.32325
25078.3450.016720.3310648.157101.27149.4348.931115.81164.740.101050.215260.31631
30090.9420.017270.2700053.87395.316149.1954.832109.35164.180.111610.198590.31020
400111.990.018410.1919263.92784.109148.0465.28996.952162.240.129650.169600.29925
500129.340.019670.1434072.91173.134146.0474.73184.582159.310.145310.143600.28891
600144.160.021210.1094881.44961.635143.0883.80371.436155.240.159890.118300.27819
800168.560.027300.058883100.8529.524130.37104.8934.200139.090.192630.0544380.24707

Sources

Values computed by Simuveliq with CoolProp 8.0.0 (downloaded from PyPI, code on GitHub), free software under the MIT license. The temperatures and pressures of the table were chosen by Simuveliq; no table was copied from a book.