Simuveliq

Ammonia (R-717) saturation table by pressure

This table gives saturation temperature and properties of saturated liquid and vapor for each pressure. Above you can use it interactively (switch units with SI/US, pick the pressure or go to the calculator for any point with step-by-step interpolation). Reference state: ASHRAE: h = 0 and s = 0 for saturated liquid at −40 °C (−40 °F).

The table as text, SI units
Specific volume [m³/kg]Internal energy [kJ/kg]Enthalpy [kJ/kg]Entropy [kJ/kg·K]
P [kPa]Tsat [°C]vfvgufufgughfhfghgsfsfgsg
40−50.3240.0014242.6781−45.7201311.11265.4−45.6631418.21372.5−0.200116.36446.1643
50−46.4960.0014342.1741−28.8521299.01270.1−28.7811407.61378.8−0.125066.21036.0852
60−43.2540.0014421.8336−14.5261288.51274.0−14.4401398.51384.0−0.0622966.08316.0208
70−40.4290.0014491.5876−2.00961279.41277.4−1.90821390.41388.5−0.00818175.97475.9665
80−37.9170.0014551.40149.14601271.21280.39.26241383.21392.40.0394995.88005.9195
90−35.6490.0014611.255319.2381263.71283.019.3691376.61395.90.0821955.79605.8782
100−33.5770.0014661.137528.4721256.81285.328.6181370.51399.10.120915.72045.8413
120−29.8930.0014760.9592144.9331244.51289.445.1101359.41404.50.189105.58845.7775
140−26.6750.0014850.8303559.3501233.61292.959.5581349.61409.20.247995.47575.7237
160−23.8070.0014930.7327472.2281223.81296.072.4671340.81413.20.299945.37725.6772
180−21.2140.0015000.6561683.9001214.81298.784.1711332.71416.80.346515.28965.6361
200−18.8420.0015070.5944194.6011206.51301.194.9021325.11420.00.388795.21075.5995
250−13.6460.0015230.48200118.111188.21306.3118.491308.31426.80.480335.04155.5218
300−9.21790.0015360.40597138.231172.31310.5138.691293.61432.30.557224.90125.4584
350−5.33860.0015480.35101155.931158.11314.0156.471280.41436.90.623794.78105.4048
400−1.87270.0015600.30936171.791145.31317.0172.411268.41440.80.682664.67565.3582
4501.26920.0015700.27668186.221133.51319.7186.931257.31444.20.735554.58155.3171
5004.14950.0015800.25031199.491122.51322.0200.281246.91447.20.783674.49655.2802
6009.29640.0015980.21036223.301102.61325.9224.261227.91452.10.868794.34735.2161
70013.8170.0016150.18147244.331084.81329.1245.461210.71456.10.942704.21895.1616
80017.8630.0016300.15958263.261068.51331.7264.561194.81459.41.00824.10585.1140
90021.5380.0016440.14239280.541053.41333.9282.021180.11462.11.06734.00455.0718
100024.9130.0016580.12853296.481039.31335.8298.141166.21464.31.12113.91255.0336
120030.9540.0016840.10751325.231013.51338.7327.251140.51467.71.21673.75024.9669
140036.2730.0017080.092319350.77989.951340.7353.171116.81470.01.30013.60934.9094
160041.0430.0017300.080801373.89968.251342.1376.661094.81471.41.37433.48444.8587
180045.3820.0017520.071758395.11947.941343.0398.261074.01472.21.44153.37164.8131
200049.3710.0017730.064463414.79928.761343.5418.341054.11472.51.50303.26844.7715
250058.1740.0018230.051171458.87884.501343.4463.421007.91471.31.63823.04204.6802
300065.7400.0018710.042168497.58844.051341.6503.19964.941468.11.75412.84744.6015
400078.4080.0019640.030697564.59770.131334.7572.44885.071457.51.94912.51764.4667
500088.8860.0020600.023644622.74701.441324.2633.04809.361442.42.11332.23564.3489
600097.8880.0021610.018822675.54634.831310.4688.51734.801423.32.25891.98044.2393
7000105.810.0022750.015278725.21567.921293.1741.13658.941400.12.39331.73884.1321
8000112.910.0024080.012516773.59498.121271.7792.85578.981371.82.52241.49974.0221
9000119.340.0025750.010241822.72421.601244.3845.89490.591336.52.65221.25003.9022
10000125.200.0028110.0082281876.15330.311206.5904.26384.491288.82.79300.965203.7582
11000130.580.0032740.0061031947.25191.301138.5983.27222.421205.72.98240.550923.5333
The table as text, English units
Specific volume [ft³/lbm]Internal energy [Btu/lbm]Enthalpy [Btu/lbm]Entropy [Btu/lbm·R]
P [psia]Tsat [°F]vfvgufufgughfhfghgsfsfgsg
5−63.0280.0227249.294−24.322567.00542.68−24.301612.59588.29−0.0594941.54451.4850
10−41.2790.0231925.794−1.4001550.43549.03−1.3571598.12596.76−0.00323481.42961.4263
15−27.2330.0235217.65713.526539.38552.9113.592588.33601.920.0318571.36051.3923
20−16.5910.0237713.49124.898530.82555.7224.986580.66605.640.0578361.31051.3683
30−0.532560.024189.225642.163517.56559.7242.297568.64610.940.0961151.23851.3346
4011.6910.024507.039655.392507.19562.5855.573559.11614.680.124561.18621.3107
5021.6940.024785.703766.277498.50564.7866.506551.04617.550.147411.14481.2922
6030.2300.025034.800175.610490.94566.5575.888543.96619.850.166641.11031.2770
7037.7160.025254.146783.833484.19568.0384.160537.58621.740.183301.08081.2641
8044.4110.025463.651691.218478.06569.2791.595531.74623.330.198051.05491.2529
9050.4850.025653.263097.944472.40570.3598.371526.32624.690.211321.03171.2430
10056.0580.025842.9495104.14467.14571.28104.62521.25625.860.223411.01071.2341
12066.0250.026172.4745115.28457.54572.82115.86511.91627.770.244810.973781.2186
14074.7880.026492.1309125.14448.88574.03125.83503.40629.230.263430.941901.2053
16082.6410.026781.8705134.04440.94574.98134.83495.53630.360.279970.913741.1937
18089.7770.027051.6661142.18433.56575.74143.08488.15631.230.294900.888441.1833
20096.3340.027321.5012149.70426.63576.33150.72481.18631.890.308530.865421.1740
250110.790.027931.2009166.47410.81577.28167.76465.07632.840.338350.815261.1536
300123.200.028510.99762181.09396.57577.66182.68450.37633.040.363760.772671.1364
350134.140.029060.85056194.18383.44577.61196.06436.64632.700.386050.735321.1214
400143.970.029600.73903206.10371.13577.23208.29423.64631.930.406030.701821.1078
500161.140.030640.58066227.42348.27575.68230.25399.16629.410.440990.642961.0839
600175.910.031670.47321246.33326.96573.29249.85375.99625.830.471260.591561.0628
800200.630.033820.33565279.66286.75566.41284.67331.43616.100.523120.501941.0251
1000221.040.036240.25001309.58247.22556.80316.28286.78603.070.568340.421300.98964
1200238.510.039240.18989338.29205.53543.81347.00238.98585.980.610860.342290.95315
1400253.800.043520.14277368.32156.76525.08379.60182.47562.070.654870.255750.91061
1600267.330.052880.096424408.6379.299487.93424.2992.191516.480.714410.126810.84123

Sources

Values computed by Simuveliq with CoolProp 8.0.0 (downloaded from PyPI, code on GitHub), free software under the MIT license. The temperatures and pressures of the table were chosen by Simuveliq; no table was copied from a book.

Full sources and licenses