Simuveliq

Tabla de saturación de amoníaco (R-717) por presión

Esta tabla da temperatura de saturación y propiedades del líquido y el vapor saturados para cada presión. Arriba puedes consultarla de forma interactiva (cambia de unidades con SI/US, elige la presión o pasa a la calculadora para cualquier punto con interpolación paso a paso). Estado de referencia: ASHRAE: h = 0 y s = 0 del líquido saturado a −40 °C (−40 °F).

La tabla en texto, unidades SI
Volumen específico [m³/kg]Energía interna [kJ/kg]Entalpía [kJ/kg]Entropía [kJ/kg·K]
P [kPa]Tsat [°C]vfvgufufgughfhfghgsfsfgsg
40−50.3240.0014242.6781−45.7201311.11265.4−45.6631418.21372.5−0.200116.36446.1643
50−46.4960.0014342.1741−28.8521299.01270.1−28.7811407.61378.8−0.125066.21036.0852
60−43.2540.0014421.8336−14.5261288.51274.0−14.4401398.51384.0−0.0622966.08316.0208
70−40.4290.0014491.5876−2.00961279.41277.4−1.90821390.41388.5−0.00818175.97475.9665
80−37.9170.0014551.40149.14601271.21280.39.26241383.21392.40.0394995.88005.9195
90−35.6490.0014611.255319.2381263.71283.019.3691376.61395.90.0821955.79605.8782
100−33.5770.0014661.137528.4721256.81285.328.6181370.51399.10.120915.72045.8413
120−29.8930.0014760.9592144.9331244.51289.445.1101359.41404.50.189105.58845.7775
140−26.6750.0014850.8303559.3501233.61292.959.5581349.61409.20.247995.47575.7237
160−23.8070.0014930.7327472.2281223.81296.072.4671340.81413.20.299945.37725.6772
180−21.2140.0015000.6561683.9001214.81298.784.1711332.71416.80.346515.28965.6361
200−18.8420.0015070.5944194.6011206.51301.194.9021325.11420.00.388795.21075.5995
250−13.6460.0015230.48200118.111188.21306.3118.491308.31426.80.480335.04155.5218
300−9.21790.0015360.40597138.231172.31310.5138.691293.61432.30.557224.90125.4584
350−5.33860.0015480.35101155.931158.11314.0156.471280.41436.90.623794.78105.4048
400−1.87270.0015600.30936171.791145.31317.0172.411268.41440.80.682664.67565.3582
4501.26920.0015700.27668186.221133.51319.7186.931257.31444.20.735554.58155.3171
5004.14950.0015800.25031199.491122.51322.0200.281246.91447.20.783674.49655.2802
6009.29640.0015980.21036223.301102.61325.9224.261227.91452.10.868794.34735.2161
70013.8170.0016150.18147244.331084.81329.1245.461210.71456.10.942704.21895.1616
80017.8630.0016300.15958263.261068.51331.7264.561194.81459.41.00824.10585.1140
90021.5380.0016440.14239280.541053.41333.9282.021180.11462.11.06734.00455.0718
100024.9130.0016580.12853296.481039.31335.8298.141166.21464.31.12113.91255.0336
120030.9540.0016840.10751325.231013.51338.7327.251140.51467.71.21673.75024.9669
140036.2730.0017080.092319350.77989.951340.7353.171116.81470.01.30013.60934.9094
160041.0430.0017300.080801373.89968.251342.1376.661094.81471.41.37433.48444.8587
180045.3820.0017520.071758395.11947.941343.0398.261074.01472.21.44153.37164.8131
200049.3710.0017730.064463414.79928.761343.5418.341054.11472.51.50303.26844.7715
250058.1740.0018230.051171458.87884.501343.4463.421007.91471.31.63823.04204.6802
300065.7400.0018710.042168497.58844.051341.6503.19964.941468.11.75412.84744.6015
400078.4080.0019640.030697564.59770.131334.7572.44885.071457.51.94912.51764.4667
500088.8860.0020600.023644622.74701.441324.2633.04809.361442.42.11332.23564.3489
600097.8880.0021610.018822675.54634.831310.4688.51734.801423.32.25891.98044.2393
7000105.810.0022750.015278725.21567.921293.1741.13658.941400.12.39331.73884.1321
8000112.910.0024080.012516773.59498.121271.7792.85578.981371.82.52241.49974.0221
9000119.340.0025750.010241822.72421.601244.3845.89490.591336.52.65221.25003.9022
10000125.200.0028110.0082281876.15330.311206.5904.26384.491288.82.79300.965203.7582
11000130.580.0032740.0061031947.25191.301138.5983.27222.421205.72.98240.550923.5333
La tabla en texto, unidades inglesas
Volumen específico [ft³/lbm]Energía interna [Btu/lbm]Entalpía [Btu/lbm]Entropía [Btu/lbm·R]
P [psia]Tsat [°F]vfvgufufgughfhfghgsfsfgsg
5−63.0280.0227249.294−24.322567.00542.68−24.301612.59588.29−0.0594941.54451.4850
10−41.2790.0231925.794−1.4001550.43549.03−1.3571598.12596.76−0.00323481.42961.4263
15−27.2330.0235217.65713.526539.38552.9113.592588.33601.920.0318571.36051.3923
20−16.5910.0237713.49124.898530.82555.7224.986580.66605.640.0578361.31051.3683
30−0.532560.024189.225642.163517.56559.7242.297568.64610.940.0961151.23851.3346
4011.6910.024507.039655.392507.19562.5855.573559.11614.680.124561.18621.3107
5021.6940.024785.703766.277498.50564.7866.506551.04617.550.147411.14481.2922
6030.2300.025034.800175.610490.94566.5575.888543.96619.850.166641.11031.2770
7037.7160.025254.146783.833484.19568.0384.160537.58621.740.183301.08081.2641
8044.4110.025463.651691.218478.06569.2791.595531.74623.330.198051.05491.2529
9050.4850.025653.263097.944472.40570.3598.371526.32624.690.211321.03171.2430
10056.0580.025842.9495104.14467.14571.28104.62521.25625.860.223411.01071.2341
12066.0250.026172.4745115.28457.54572.82115.86511.91627.770.244810.973781.2186
14074.7880.026492.1309125.14448.88574.03125.83503.40629.230.263430.941901.2053
16082.6410.026781.8705134.04440.94574.98134.83495.53630.360.279970.913741.1937
18089.7770.027051.6661142.18433.56575.74143.08488.15631.230.294900.888441.1833
20096.3340.027321.5012149.70426.63576.33150.72481.18631.890.308530.865421.1740
250110.790.027931.2009166.47410.81577.28167.76465.07632.840.338350.815261.1536
300123.200.028510.99762181.09396.57577.66182.68450.37633.040.363760.772671.1364
350134.140.029060.85056194.18383.44577.61196.06436.64632.700.386050.735321.1214
400143.970.029600.73903206.10371.13577.23208.29423.64631.930.406030.701821.1078
500161.140.030640.58066227.42348.27575.68230.25399.16629.410.440990.642961.0839
600175.910.031670.47321246.33326.96573.29249.85375.99625.830.471260.591561.0628
800200.630.033820.33565279.66286.75566.41284.67331.43616.100.523120.501941.0251
1000221.040.036240.25001309.58247.22556.80316.28286.78603.070.568340.421300.98964
1200238.510.039240.18989338.29205.53543.81347.00238.98585.980.610860.342290.95315
1400253.800.043520.14277368.32156.76525.08379.60182.47562.070.654870.255750.91061
1600267.330.052880.096424408.6379.299487.93424.2992.191516.480.714410.126810.84123

Fuentes

Valores calculados por Simuveliq con CoolProp 8.0.0 (descargado de PyPI, código en GitHub), software libre de licencia MIT. Las temperaturas y presiones de la tabla las eligió Simuveliq; ninguna tabla se copió de un libro.

Fuentes y licencias completas

Tablas

Más herramientas

English version

© 2026 Simuveliq. Todos los derechos reservados.