Simuveliq

Tabla de vapor sobrecalentado de R-1234yf

Esta tabla da v, u, h y s del vapor sobrecalentado en bloques de presión. Arriba puedes consultarla de forma interactiva (cambia de unidades con SI/US, elige la presión o pasa a la calculadora para cualquier punto con interpolación paso a paso). Estado de referencia: ASHRAE: h = 0 y s = 0 del líquido saturado a −40 °C (−40 °F).

La tabla en texto, unidades SI
P = 0.015 MPa (Tsat = −65.456 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.99783154.14169.100.82255
−601.0251157.63173.010.84110
−401.1246171.00187.870.90770
−201.2234185.20203.550.97222
01.3219200.21220.041.0349
201.4200216.02237.321.0959
401.5179232.59255.361.1554
601.6157249.91274.141.2136
801.7134267.94293.641.2704
1001.8110286.66313.821.3260
1201.9085306.04334.671.3804
P = 0.025 MPa (Tsat = −57.096 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.61948159.24174.730.81238
−400.67126170.77187.550.86949
−200.73125185.02203.300.93427
00.79080200.07219.840.99713
200.85005215.90237.151.0583
400.90910232.49255.221.1179
600.96800249.82274.021.1761
801.0268267.86293.531.2329
1001.0855286.59313.731.2886
1201.1442305.98334.581.3430
P = 0.04 MPa (Tsat = −48.663 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.39950164.47180.460.80479
−400.41622170.43187.080.83375
−200.45436184.75202.930.89894
00.49206199.85219.540.96206
200.52945215.72236.901.0234
400.56663232.34255.001.0831
600.60366249.69273.841.1414
800.64059267.75293.371.1984
1000.67743286.49313.591.2540
1200.71422305.89334.461.3085
P = 0.06 MPa (Tsat = −40.735 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.27350169.45185.860.79971
−400.27447169.97186.440.80218
−200.30050184.39202.420.86793
00.32607199.56219.130.93143
200.35132215.48236.560.99301
400.37636232.14254.721.0529
600.40124249.52273.591.1113
800.42602267.60293.161.1684
1000.45072286.36313.401.2241
1200.47536305.77334.291.2786
P = 0.1 MPa (Tsat = −29.757 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.16942176.42193.360.79540
−200.17735183.64201.380.82769
00.19324198.96218.290.89198
200.20879214.99235.870.95409
400.22412231.73254.141.0144
600.23930249.17273.101.0730
800.25436267.29292.731.1302
1000.26934286.09313.021.1861
1200.28426305.53333.951.2408
P = 0.2 MPa (Tsat = −12.770 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.087958187.27204.860.79351
00.093481197.40216.090.83560
200.10182213.72234.090.89917
400.10991230.68252.660.96043
600.11781248.27271.831.0198
800.12560266.52291.641.0775
1000.13330285.40312.061.1338
1200.14093304.92333.101.1887
P = 0.3 MPa (Tsat = −1.5113 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.059611194.46212.340.79456
00.060081195.70213.730.79964
200.066082212.38232.210.86494
400.071782229.58251.110.92731
600.077288247.35270.530.98742
800.082661265.72290.521.0457
1000.087940284.71311.091.1023
1200.093149304.29332.241.1575
P = 0.5 MPa (Tsat = 14.322 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.036136204.42222.490.79798
200.037304209.43228.090.81725
400.041181227.23247.820.88237
600.044806245.41267.810.94424
800.048272264.07288.211.0037
1000.051629283.27309.091.0612
1200.054907303.02330.481.1170
P = 0.8 MPa (Tsat = 30.765 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.022404214.39232.310.80252
400.023756223.20242.200.83459
600.026422242.21263.350.90004
800.028862261.42284.510.96174
1000.031164281.01305.941.0208
1200.033372301.05327.751.0777
P = 1.5 MPa (Tsat = 56.032 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.011201227.93244.730.80709
600.011645232.45249.910.82274
800.013540254.08274.390.89412
1000.015127275.06297.750.95846
1200.016556296.02320.851.0188
P = 2.5 MPa (Tsat = 79.620 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.0056290235.26249.330.79727
800.0056827235.94250.150.79959
1000.0075144263.83282.620.88917
1200.0087401287.43309.280.95879
P = 4 MPa
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
1000.0015789204.89211.200.68012
1200.0040364268.17284.310.87211
P = 6 MPa
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
1000.0012550189.61197.140.63517
1200.0016254228.58238.340.74260
P = 10 MPa
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
1000.0011229179.69190.910.60586
1200.0012483210.29222.770.68901
La tabla en texto, unidades inglesas
P = 1.5 psia (Tsat = −95.937 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.22.61964.81471.0920.19851
−7523.95967.98174.6310.20797
−5025.55471.93079.0230.21902
−2527.14376.05783.5910.22984
028.72880.35688.3300.24044
2530.31084.82493.2370.25084
5031.89089.45898.3100.26104
7533.46794.254103.540.27107
10035.04499.209108.940.28092
12536.619104.32114.480.29062
15038.193109.58120.180.30016
17539.766114.99126.030.30956
20041.339120.54132.010.31881
22542.911126.23138.140.32793
25044.483132.06144.400.33691
27546.055138.01150.790.34576
P = 2.5 psia (Tsat = −81.863 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.14.03966.84173.3350.19576
−7514.30667.89774.5150.19885
−5015.27371.86078.9250.20996
−2516.23575.99783.5080.22081
017.19380.30588.2590.23144
2518.14884.78093.1760.24185
5019.10089.41998.2550.25207
7520.05094.220103.500.26211
10020.99999.178108.890.27197
12521.947104.29114.440.28168
15022.894109.56120.150.29122
17523.840114.97126.000.30062
20024.785120.52131.990.30988
22525.730126.21138.120.31900
25026.675132.04144.380.32799
27527.619138.00150.770.33684
P = 4 psia (Tsat = −67.714 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.9.054568.91375.6150.19362
−509.489671.75378.7770.20151
−2510.09975.90783.3820.21242
010.70480.22888.1510.22309
2511.30684.71493.0820.23353
5011.90589.36298.1740.24377
7512.50394.169103.420.25383
10013.09999.133108.830.26371
12513.694104.25114.390.27342
15014.288109.52120.090.28298
17514.881114.93125.950.29239
20015.474120.49131.940.30165
22516.066126.18138.080.31078
25016.658132.01144.340.31976
27517.249137.97150.740.32862
P = 6 psia (Tsat = −54.453 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.6.201570.88277.7670.19211
−506.275871.60878.5760.19409
−256.689575.78583.2120.20508
07.098880.12488.0060.21580
257.504984.62492.9570.22628
507.908489.28498.0640.23656
758.310094.100103.330.24664
1008.710199.072108.740.25654
1259.1090104.20114.310.26627
1509.5070109.47120.030.27584
1759.9042114.89125.880.28526
20010.301120.45131.880.29453
22510.697126.15138.020.30366
25011.093131.98144.290.31265
27511.488137.94150.690.32151
P = 10 psia (Tsat = −36.154 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.3.846673.63280.7500.19067
−253.960975.53582.8650.19560
04.214079.91387.7110.20644
254.463584.44392.7030.21701
504.710489.12697.8430.22735
754.955493.962103.130.23748
1005.198798.950108.570.24742
1255.4409104.09114.160.25718
1505.6821109.37119.890.26678
1755.9225114.80125.760.27622
2006.1623120.36131.770.28551
2256.4016126.07137.910.29465
2506.6405131.91144.190.30366
2756.8789137.87150.600.31253
P = 20 psia (Tsat = −7.9751 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.2.004977.91785.3370.18963
02.048179.36186.9410.19315
252.181083.97492.0460.20396
502.310988.72297.2750.21448
752.438693.609102.640.22475
1002.564798.638108.130.23479
1252.6894103.81113.760.24463
1502.8131109.12119.530.25429
1752.9360114.57125.440.26379
2003.0583120.16131.470.27312
2253.1800125.88137.650.28230
2503.3013131.73143.940.29134
2753.4221137.70150.370.30023
P = 30 psia (Tsat = 10.623 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.1.364580.75988.3340.18953
251.418583.47991.3540.19586
501.510088.30096.6830.20658
751.599093.244102.120.21699
1001.686198.317107.680.22715
1251.7719103.52113.360.23708
1501.8565108.86119.170.24681
1751.9403114.34125.110.25636
2002.0235119.94131.180.26573
2252.1060125.68137.370.27495
2502.1881131.54143.690.28402
2752.2698137.53150.140.29294
P = 50 psia (Tsat = 36.688 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.8344484.72592.4450.18995
500.8669587.39495.4160.19585
750.9257192.471101.040.20662
1000.9822297.645106.730.21703
1251.0371102.93112.530.22716
1501.0907108.33118.430.23704
1751.1434113.86124.440.24671
2001.1953119.51130.570.25618
2251.2466125.28136.820.26547
2501.2974131.18143.180.27460
2751.3479137.19149.660.28358
P = 80 psia (Tsat = 63.678 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.5247488.75796.5260.19080
750.5439891.18099.2330.19592
1000.5842996.550105.200.20683
1250.62243101.98111.200.21731
1500.65902107.50117.250.22746
1750.69445113.11123.390.23733
2000.72901118.84129.630.24696
2250.76288124.67135.960.25638
2500.79620130.61142.400.26562
2750.82908136.67148.940.27468
P = 150 psia (Tsat = 105.09 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.2731694.587102.170.19227
1250.2952699.367107.560.20166
1500.32025105.28114.170.21273
1750.34328111.19120.720.22325
2000.36496117.13127.260.23336
2250.38569123.14133.840.24316
2500.40569129.22140.480.25268
2750.42512135.40147.200.26198
P = 250 psia (Tsat = 143.91 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.1515099.146106.160.19268
1500.15749100.91108.200.19606
1750.17835107.74115.990.20858
2000.19587114.25123.310.21990
2250.21155120.65130.430.23049
2500.22604127.02137.480.24060
2750.23972133.42144.510.25033
P = 400 psia (Tsat = 184.03 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.076007101.02106.650.18867
2000.093090107.74114.630.20093
2250.10988115.77123.900.21474
2500.12294123.02132.120.22653
2750.13423129.99139.920.23734
P = 600 psia
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
2250.038302100.30104.550.18255
2500.061258115.03121.830.20741
2750.073734124.07132.260.22186
P = 1000 psia
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
2250.02051585.48389.2790.15766
2500.02362096.229100.600.17389
2750.028819107.86113.200.19134

Fuentes

Valores calculados por Simuveliq con CoolProp 8.0.0 (descargado de PyPI, código en GitHub), software libre de licencia MIT. Las temperaturas y presiones de la tabla las eligió Simuveliq; ninguna tabla se copió de un libro.

Fuentes y licencias completas

Tablas