Simuveliq

Tabla de vapor sobrecalentado de R-404A

Esta tabla da v, u, h y s del vapor sobrecalentado en bloques de presión. Arriba puedes consultarla de forma interactiva (cambia de unidades con SI/US, elige la presión o pasa a la calculadora para cualquier punto con interpolación paso a paso). Estado de referencia: ASHRAE: h = 0 y s = 0 del líquido saturado a −40 °C (−40 °F).

La tabla en texto, unidades SI
P = 0.05 MPa (Tsat = −59.071 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.35385167.09184.780.87067
−400.38891179.67199.110.93479
−200.42478193.44214.680.99883
00.46010207.88230.881.0604
200.49508223.01247.761.1200
400.52983238.84265.331.1780
600.56445255.36283.591.2345
800.59895272.57302.521.2897
1000.63338290.44322.101.3436
1200.66776308.94342.331.3964
1400.70209328.06363.161.4481
1600.73638347.76384.581.4987
1800.77064368.03406.571.5483
2000.80489388.85429.091.5970
2200.83911410.18452.131.6446
P = 0.08 MPa (Tsat = −50.247 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.22773171.95190.160.85667
−400.23989178.91198.100.89148
−200.26300192.88213.920.95657
00.28556207.45230.291.0188
200.30777222.66247.281.0788
400.32976238.56264.941.1371
600.35159255.13283.251.1937
800.37332272.36302.231.2490
1000.39498290.25321.851.3031
1200.41657308.78342.101.3559
1400.43813327.91362.961.4077
1600.45964347.63384.401.4584
1800.48113367.91406.401.5080
2000.50259388.74428.941.5567
2200.52404410.07451.991.6044
P = 0.15 MPa (Tsat = −36.983 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.12591179.26198.150.84062
−200.13711191.55212.120.89772
00.14976206.43228.890.96149
200.16206221.85246.161.0225
400.17412237.89264.001.0814
600.18603254.56282.461.1385
800.19783271.88301.551.1941
1000.20955289.83321.261.2484
1200.22121308.40341.581.3014
1400.23282327.57362.491.3533
1600.24440347.32383.981.4041
1800.25595367.63406.021.4539
2000.26748388.47428.601.5026
2200.27898409.83451.681.5504
P = 0.25 MPa (Tsat = −24.746 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.077398185.96205.310.82984
−200.079426189.57209.430.84625
00.087614204.92226.830.91239
200.095406220.66244.510.97487
400.10295236.91262.651.0347
600.11033253.74281.321.0925
800.11759271.17300.571.1486
1000.12477289.21320.401.2032
1200.13189307.85340.821.2565
1400.13897327.08361.821.3086
1600.14600346.88383.381.3596
1800.15301367.22405.481.4094
2000.15999388.10428.101.4583
2200.16696409.48451.221.5062
P = 0.4 MPa (Tsat = −12.121 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.049100192.73212.370.82153
00.052539202.53223.550.86340
200.057851218.80241.940.92839
400.062877235.41260.560.98981
600.067722252.49279.571.0487
800.072443270.10299.071.1055
1000.077077288.27319.101.1607
1200.081647307.02339.681.2144
1400.086169326.33360.801.2668
1600.090653346.20382.461.3180
1800.095106366.61404.651.3680
2000.099536387.54427.351.4170
2200.10394408.96450.541.4650
P = 0.6 MPa (Tsat = −0.014275 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.032849198.97218.680.81526
00.032852198.98218.690.81532
200.036890216.15238.290.88455
400.040562233.31257.640.94842
600.044021250.75277.161.0088
800.047342268.63297.031.0668
1000.050569287.00317.341.1227
1200.053727305.90338.131.1770
1400.056834325.33359.431.2298
1600.059901345.30381.241.2813
1800.062937365.78403.551.3317
2000.065948386.78426.351.3809
2200.068938408.26449.631.4291
P = 1 MPa (Tsat = 17.081 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.019380207.09226.470.80737
200.019828209.92229.750.81862
400.022572228.66251.230.88954
600.024986247.03272.020.95389
800.027219265.53292.751.0143
1000.029337284.35313.681.0720
1200.031376303.58334.961.1275
1400.033357323.28356.631.1813
1600.035295343.45378.751.2335
1800.037200364.11401.311.2845
2000.039078385.25424.331.3342
2200.040935406.85447.791.3827
P = 2 MPa (Tsat = 44.062 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.0087101216.40233.820.78921
600.010376235.43256.180.85805
800.011966256.60280.530.92907
1000.013329277.02303.680.99282
1200.014568297.34326.481.0523
1400.015727317.84349.301.1090
1600.016832338.63372.301.1633
1800.017897359.78395.571.2159
2000.018930381.32419.181.2668
2200.019940403.25443.131.3164
P = 3 MPa (Tsat = 62.014 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.0047476215.79230.030.75779
800.0066283244.62264.500.85827
1000.0078891268.27291.940.93388
1200.0089182290.31317.070.99950
1400.0098311311.91341.411.0599
1600.010672333.49365.511.1169
1800.011465355.23389.631.1713
2000.012221377.24413.901.2237
2200.012951399.55438.401.2744
P = 5 MPa
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
800.0014604179.56186.860.61854
1000.0032456241.76257.990.81492
1200.0043171272.78294.370.91002
1400.0050959298.28323.760.98297
1600.0057522322.18350.941.0472
1800.0063385345.50377.191.1065
2000.0068790368.66403.061.1623
2200.0073870391.88428.811.2157
P = 8 MPa
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
800.0011887163.69173.200.56896
1000.0014521200.08211.700.67491
1200.0019573239.62255.280.78866
1400.0025557274.05294.500.88605
1600.0030811303.16327.810.96483
1800.0035384329.74358.051.0331
2000.0039482355.13386.721.0950
2200.0043242379.98414.581.1527
P = 10 MPa
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
800.0011284158.77170.050.55350
1000.0012947191.31204.250.64767
1200.0015572225.77241.350.74447
1400.0019212259.83279.040.83800
1600.0023158290.94314.100.92089
1800.0026901319.38346.280.99356
2000.0030352346.21376.561.0590
2200.0033544372.15405.691.1193
La tabla en texto, unidades inglesas
P = 8 psia (Tsat = −71.136 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.5.170172.25479.9070.20722
−505.486875.58483.7070.21675
06.215783.80093.0020.23814
506.928092.558102.810.25840
1007.6319101.89113.190.27781
1508.3308111.80124.130.29652
2009.0268122.26135.620.31464
2509.7208133.26147.650.33220
30010.414144.76160.180.34926
35011.105156.75173.190.36584
40011.796169.19186.650.38197
P = 15 psia (Tsat = −49.083 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.2.865375.15883.1110.20296
03.266583.42392.4900.22453
503.658692.292102.450.24508
1004.0420101.69112.910.26465
1504.4204111.64123.910.28347
2004.7957122.13135.440.30165
2505.1691133.15147.490.31926
3005.5411144.67160.050.33635
3505.9120156.66173.070.35295
4006.2823169.11186.550.36909
P = 25 psia (Tsat = −28.828 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.1.767877.82486.0030.20003
01.917182.87291.7410.21292
502.163591.905101.910.23392
1002.4006101.40112.500.25374
1502.6326111.41123.590.27270
2002.8615121.94135.180.29097
2503.0883132.99147.270.30864
3003.3137144.53159.860.32577
3503.5381156.54172.910.34241
4003.7617169.00186.400.35857
P = 40 psia (Tsat = −8.0037 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.1.128280.53788.8880.19776
01.156282.00890.5660.20144
501.321691.308101.090.22318
1001.4769100.95111.890.24338
1501.6268111.06123.100.26256
2001.7733121.65134.780.28097
2501.9178132.74146.940.29873
3002.0608144.32159.570.31593
3502.2027156.36172.660.33261
4002.3439168.84186.190.34882
P = 60 psia (Tsat = 11.909 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.7610183.07691.5250.19609
500.8527090.47399.9410.21325
1000.96323100.34111.040.23402
1501.0677110.58122.440.25352
2001.1687121.26134.240.27213
2501.2674132.42146.490.29002
3001.3646144.04159.190.30731
3501.4608156.11172.330.32406
4001.5562168.62185.900.34032
P = 100 psia (Tsat = 39.962 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.4571286.48994.9480.19423
500.4742388.61697.3910.19907
1000.5509399.046109.240.22125
1500.61981109.59121.060.24148
2000.68462120.47133.140.26051
2500.74696131.75145.570.27868
3000.80770143.47158.410.29616
3500.86731155.61171.660.31305
4000.92610168.18185.310.32941
P = 200 psia (Tsat = 84.224 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.2181591.12399.1960.19132
1000.2357895.092103.820.19970
1500.28163106.83117.250.22271
2000.32057118.33130.190.24311
2500.35617130.01143.190.26210
3000.38980141.99156.420.28011
3500.42213154.34169.960.29737
4000.45355167.05183.840.31400
P = 300 psia (Tsat = 113.88 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.1335593.151100.560.18813
1500.16568103.43112.630.20856
2000.19805115.93126.930.23111
2500.22544128.13140.640.25116
3000.25034140.44154.340.26981
3500.27372153.02168.210.28749
4000.29609165.90182.340.30442
P = 500 psia (Tsat = 155.24 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.05568090.35595.5070.17414
2000.096923109.83118.800.21096
2500.11996123.86134.960.23459
3000.13855137.09149.910.25496
3500.15505150.23164.580.27366
4000.17030163.52179.270.29127
P = 800 psia
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
2000.03238991.48296.2770.17176
2500.059499115.61124.420.21309
3000.075743131.33142.550.23780
3500.088701145.71158.840.25858
4000.10004159.75174.560.27742
P = 1500 psia
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
2000.01950477.06882.4820.14641
2500.02460397.164103.990.17782
3000.032348116.96125.940.20772
3500.040495134.59145.830.23309
4000.047916150.73164.030.25491

Fuentes

Valores calculados por Simuveliq con CoolProp 8.0.0 (descargado de PyPI, código en GitHub), software libre de licencia MIT. Las temperaturas y presiones de la tabla las eligió Simuveliq; ninguna tabla se copió de un libro.

Fuentes y licencias completas

Tablas

Más herramientas

English version

© 2026 Simuveliq. Todos los derechos reservados.