Esta tabla da v, u, h y s del vapor sobrecalentado en bloques de presión. Arriba puedes consultarla de forma interactiva (cambia de unidades con SI/US, elige la presión o pasa a la calculadora para cualquier punto con interpolación paso a paso). Estado de referencia: NBP: h = 0 y s = 0 del líquido saturado en el punto de ebullición normal (1 atm).

La tabla en texto, unidades SI
P = 0.01 MPa (Tsat = −200.47 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.1.8776180.04198.812.7787
−2001.8900180.37199.272.7849
−1503.1957213.01244.973.2614
−1004.4969245.54290.513.5718
−505.7970278.08336.053.8028
07.0967310.73381.693.9874
508.3962343.65427.614.1417
1009.6956377.04474.004.2752
15010.995411.08521.024.3934
20012.294445.85568.794.5001
25013.593481.42617.354.5976
30014.893517.77666.704.6877
35016.192554.90716.824.7716
40017.491592.75767.664.8500
P = 0.02 MPa (Tsat = −196.05 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.99194182.78202.622.6508
−1501.5958212.94244.853.0807
−1002.2474245.50290.453.3914
−502.8979278.05336.013.6226
03.5480310.70381.663.8072
504.1979343.63427.593.9616
1004.8477377.03473.984.0950
1505.4975411.06521.014.2133
2006.1472445.84568.784.3200
2506.7969481.41617.344.4175
3007.4465517.77666.704.5076
3508.0962554.89716.824.5915
4008.7458592.75767.664.6699
P = 0.03 MPa (Tsat = −193.18 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.68356184.53205.042.5774
−1501.0625212.86244.742.9747
−1001.4976245.46290.383.2858
−501.9315278.02335.973.5171
02.3651310.68381.633.7017
502.7985343.61427.573.8561
1003.2318377.01473.973.9896
1503.6650411.05521.004.1079
2004.0982445.83568.774.2146
2504.5313481.40617.344.3121
3004.9645517.76666.694.4023
3505.3976554.89716.814.4861
4005.8307592.74767.664.5646
P = 0.05 MPa (Tsat = −189.21 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.42787186.88208.272.4863
−1500.63586212.71244.502.8407
−1000.89769245.37290.263.1526
−501.1584277.96335.883.3841
01.4188310.64381.573.5688
501.6790343.58427.523.7233
1001.9390376.99473.943.8568
1502.1990411.03520.983.9751
2002.4590445.81568.764.0818
2502.7189481.38617.324.1794
3002.9788517.74666.684.2695
3503.2387554.87716.814.3533
4003.4986592.73767.664.4318
P = 0.08 MPa (Tsat = −185.16 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.27807189.18211.422.4036
−1500.39586212.47244.142.7167
−1000.56026245.24290.063.0297
−500.72357277.87335.763.2616
00.88649310.57381.493.4465
501.0492343.52427.463.6010
1001.2118376.94473.893.7346
1501.3744410.99520.943.8529
2001.5369445.78568.733.9596
2501.6994481.35617.304.0572
3001.8619517.72666.674.1473
3502.0244554.85716.804.2312
4002.1868592.71767.654.3097
P = 0.15 MPa (Tsat = −179.03 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.15608192.40215.812.2942
−1500.20917211.93243.302.5489
−1000.29781244.94289.612.8646
−500.38534277.67335.473.0973
00.47248310.41381.283.2826
500.55942343.40427.313.4373
1000.64626376.84473.783.5710
1500.73304410.90520.863.6894
2000.81978445.70568.673.7961
2500.90649481.29617.263.8938
3000.99318517.66666.643.9839
3501.0798554.80716.784.0678
4001.1665592.66767.644.1463
P = 0.25 MPa (Tsat = −173.34 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.097350195.07219.412.2054
−1500.12379211.12242.072.4095
−1000.17783244.50288.952.7293
−500.23073277.37335.052.9633
00.28322310.19380.993.1490
500.33552343.22427.103.3040
1000.38771376.69473.623.4379
1500.43985410.78520.753.5564
2000.49194445.60568.583.6632
2500.54400481.20617.203.7609
3000.59605517.58666.593.8510
3500.64808554.73716.753.9349
4000.70010592.60767.624.0134
P = 0.4 MPa (Tsat = −167.42 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.062779197.46222.572.1230
−1500.075710209.87240.162.2770
−1000.11034243.83287.962.6033
−500.14375276.92334.422.8391
00.17676309.85380.563.0257
500.20957342.96426.793.1811
1000.24228376.48473.393.3152
1500.27493410.60520.573.4338
2000.30753445.44568.463.5408
2500.34011481.06617.103.6385
3000.37267517.46666.533.7287
3500.40521554.62716.713.8126
4000.43774592.50767.603.8912
P = 0.6 MPa (Tsat = −161.69 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.042750199.32224.972.0502
−1500.048926208.10237.462.1568
−1000.072837242.93286.632.4928
−500.095435276.32333.582.7311
00.11761309.41379.972.9187
500.13960342.60426.373.0746
1000.16148376.19473.083.2090
1500.18330410.36520.343.3279
2000.20508445.23568.283.4350
2500.22683480.88616.983.5328
3000.24856517.30666.443.6231
3500.27028554.48716.653.7070
4000.29198592.38767.573.7856
P = 1 MPa (Tsat = −153.53 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.026004201.06227.071.9540
−1500.027297204.09231.391.9896
−1000.042817241.07283.892.3492
−500.056780275.10331.882.5929
00.070302308.51378.812.7827
500.083629341.89425.522.9397
1000.096850375.61472.463.0748
1500.11001409.87519.883.1940
2000.12312444.82567.943.3013
2500.13621480.52616.733.3994
3000.14928516.98666.263.4898
3500.16234554.20716.533.5739
4000.17538592.12767.503.6525
P = 2 MPa (Tsat = −140.41 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.012634200.78226.051.8042
−1000.020252236.10276.602.1398
−500.027789272.00327.582.3989
00.034825306.24375.892.5943
500.041656340.12423.432.7542
1000.048380374.16470.922.8908
1500.055041408.65518.743.0111
2000.061661443.78567.103.1191
2500.068253479.61616.123.2175
3000.074825516.19665.843.3083
3500.081383553.49716.263.3926
4000.087930591.49767.353.4715
P = 3 MPa (Tsat = −131.46 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.0078014196.85220.261.6898
−1000.012674230.55268.572.0012
−500.018127268.79323.172.2792
00.023006303.95372.972.4807
500.027672338.34421.362.6434
1000.032229372.71469.402.7816
1500.036723407.44517.612.9029
2000.041176442.74566.273.0116
2500.045602478.71615.523.1105
3000.050008515.40665.423.2016
3500.054400552.79715.993.2862
4000.058781590.86767.203.3652
P = 5 MPa (Tsat = −118.79 °C)
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
Sat.0.0028004165.54179.541.3487
−1000.0064792216.84249.241.7847
−500.010405262.07314.092.1165
00.013566299.31367.142.3313
500.016498334.78417.272.4999
1000.019319369.84466.432.6414
1500.022077405.04515.432.7646
2000.024795440.69564.672.8746
2500.027487476.93614.372.9744
3000.030159513.83664.623.0662
3500.032817551.39715.483.1512
4000.035465589.60766.933.2306
P = 8 MPa
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
−1000.0027710183.40205.561.4571
−500.0060904251.25299.971.9469
00.0082856292.23358.512.1843
500.010235329.45411.332.3620
1000.012075365.56462.162.5083
1500.013852401.49512.302.6344
2000.015592437.66562.392.7463
2500.017305474.30612.742.8474
3000.019001511.51663.522.9401
3500.020683549.33714.793.0259
4000.022355587.75766.593.1058
P = 15 MPa
T [°C]v [m³/kg]u [kJ/kg]h [kJ/kg]s [kJ/kg·K]
−1000.0014567138.16160.011.1213
−500.0029240224.77268.631.6765
00.0042774275.78339.941.9664
500.0054296317.31398.752.1644
1000.0064867355.90453.202.3212
1500.0074903393.47505.822.4535
2000.0084604430.82557.732.5695
2500.0094079468.36609.482.6735
3000.010339506.28661.372.7682
3500.011259544.66713.552.8555
4000.012170583.55766.102.9366
La tabla en texto, unidades inglesas
P = 1.5 psia (Tsat = −328.48 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.29.15777.45685.5490.66217
−30035.58381.93891.8150.70543
−20058.00897.485113.590.81131
−10080.390113.02135.340.88217
0102.76128.59157.110.93558
100125.12144.27179.000.97866
200147.49160.17201.111.0150
300169.85176.40223.551.0467
400192.21193.03246.381.0749
500214.57210.07269.631.1005
600236.93227.53293.301.1239
700259.29245.40317.371.1456
800281.64263.64341.811.1659
P = 2.5 psia (Tsat = −322.68 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.18.21778.31886.7460.63962
−30021.30381.90591.7600.67352
−20034.78697.468113.560.77954
−10048.224113.01135.320.85044
061.650128.58157.100.90387
10075.072144.26178.990.94695
20088.491160.17201.100.98329
300101.91176.40223.541.0150
400115.33193.02246.381.0432
500128.74210.07269.631.0688
600142.16227.53293.301.0922
700155.57245.40317.371.1139
800168.99263.63341.811.1341
P = 4 psia (Tsat = −316.83 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.11.82979.17487.9300.61922
−30013.27081.85291.6740.64402
−20021.72397.442113.520.75028
−10030.131113.00135.300.82123
038.526128.57157.090.87467
10046.917144.25178.980.91776
20055.306160.16201.100.95412
30063.693176.39223.540.98579
40072.080193.02246.371.0140
50080.466210.06269.621.0396
60088.851227.53293.301.0631
70097.237245.39317.371.0848
800105.62263.63341.811.1050
P = 6 psia (Tsat = −311.32 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.8.154479.96189.0150.60188
−3008.806281.77891.5550.61838
−20014.46697.407113.470.72498
−10020.079112.98135.270.79601
025.680128.56157.070.84948
10031.276144.24178.970.89258
20036.870160.15201.090.92894
30042.462176.39223.530.96061
40048.054193.01246.370.98885
50053.645210.06269.621.0144
60059.236227.52293.291.0379
70064.827245.39317.371.0596
80070.417263.63341.811.0798
P = 10 psia (Tsat = −303.68 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.5.104981.01490.4600.58032
−3005.234381.61591.3010.58565
−2008.659897.338113.360.69301
−10012.037112.94135.210.76419
015.402128.53157.030.81771
10018.763144.22178.940.86084
20022.121160.13201.070.89721
30025.478176.37223.520.92889
40028.834193.00246.360.95713
50032.189210.05269.610.98272
60035.544227.51293.291.0062
70038.899245.38317.361.0279
80042.253263.62341.811.0481
P = 20 psia (Tsat = −291.83 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.2.701482.53092.5280.55144
−2004.305397.162113.100.64931
−1006.0062112.83135.060.72088
07.6946128.45156.930.77454
1009.3782144.16178.870.81772
20011.059160.09201.020.85413
30012.739176.34223.480.88583
40014.418192.97246.330.91408
50016.097210.02269.600.93967
60017.775227.49293.280.96314
70019.453245.36317.360.98486
80021.131263.60341.811.0051
P = 30 psia (Tsat = −283.96 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.1.858683.44293.7600.53463
−2002.853796.985112.830.62346
−1003.9958112.73134.910.69543
05.1253128.38156.830.74922
1006.2499144.11178.810.79246
2007.3722160.04200.970.82890
3008.4932176.30223.450.86062
4009.6133192.94246.310.88888
50010.733210.00269.580.91448
60011.852227.47293.260.93796
70012.971245.34317.350.95967
80014.090263.59341.810.97990
P = 50 psia (Tsat = −272.86 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.1.156084.57595.2710.51333
−2001.692196.624112.280.59036
−1002.3874112.52134.610.66315
03.0698128.24156.640.71720
1003.7473144.00178.670.76056
2004.4225159.96200.880.79706
3005.0962176.23223.380.82882
4005.7692192.88246.260.85711
5006.4416209.94269.540.88273
6007.1137227.42293.240.90621
7007.7855245.30317.340.92794
8008.4571263.55341.800.94817
P = 80 psia (Tsat = −261.28 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.7420785.53596.5200.49333
−2001.038396.066111.440.55901
−1001.4827112.20134.150.63310
01.9137128.02156.350.68756
1002.3396143.83178.470.73110
2002.7632159.82200.730.76769
3003.1855176.12223.280.79951
4003.6069192.79246.180.82783
5004.0278209.86269.490.85348
6004.4483227.35293.210.87698
7004.8686245.24317.310.89872
8005.2886263.50341.790.91896
P = 150 psia (Tsat = −243.31 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.4028386.47597.6560.46512
−2000.5284394.677109.340.51450
−1000.77896111.45133.070.59199
01.0144127.50155.660.64743
1001.2448143.44178.000.69140
2001.4728159.52200.400.72822
3001.6994175.86223.030.76016
4001.9252192.57246.010.78857
5002.1504209.68269.370.81427
6002.3753227.19293.130.83782
7002.5999245.10317.270.85959
8002.8243263.37341.770.87985
P = 250 psia (Tsat = −226.20 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.2380086.53797.5480.43936
−2000.2929792.413105.970.47361
−1000.45711110.35131.490.55720
00.60343126.76154.680.61412
1000.74439142.89177.320.65871
2000.88291159.07199.920.69585
3001.0201175.50222.690.72799
4001.1564192.27245.770.75652
5001.2922209.42269.200.78230
6001.4277226.97293.010.80590
7001.5628244.90317.200.82771
8001.6978263.19341.740.84801
P = 400 psia (Tsat = −208.11 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.1390585.17195.4640.41002
−2000.1547987.89999.3570.42527
−1000.27591108.61129.030.52315
00.37233125.63153.190.58251
1000.46302142.05176.320.62806
2000.55120158.42199.220.66570
3000.63803174.96222.190.69812
4000.72404191.81245.410.72683
5000.80952209.03268.950.75273
6000.89465226.63292.850.77642
7000.97951244.60317.100.79829
8001.0642262.93341.700.81863
P = 600 psia (Tsat = −190.56 °F)
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
Sat.0.07729580.54489.1260.37087
−1000.17508106.13125.560.49101
00.24409124.10151.200.55406
1000.30684140.93175.000.60094
2000.36703157.54198.290.63923
3000.42587174.25221.530.67203
4000.48390191.21244.940.70098
5000.54141208.51268.630.72704
6000.59857226.18292.640.75084
7000.65547244.21316.980.77279
8000.71218262.57341.650.79319
P = 1000 psia
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
−1000.094319100.52117.970.44359
00.14190120.95147.210.51571
1000.18223138.69172.410.56537
2000.21995155.80196.500.60498
3000.25634172.83220.260.63852
4000.29194190.02244.050.66793
5000.32704207.50268.010.69431
6000.36180225.29292.240.71832
7000.39631243.42316.760.74043
8000.43065261.88341.570.76094
P = 2000 psia
T [°F]v [ft³/lbm]u [Btu/lbm]h [Btu/lbm]s [Btu/lbm·R]
−1000.03815784.35998.4810.35925
00.067050112.91137.730.45658
1000.089921133.16166.440.51325
2000.11043151.56192.430.55600
3000.12977169.39217.420.59128
4000.14841187.14242.070.62177
5000.16660205.03266.690.64886
6000.18449223.14291.420.67337
7000.20217241.52316.340.69584
8000.21968260.18341.480.71664

Fuentes

Valores calculados por Simuveliq con CoolProp 8.0.0 (descargado de PyPI, código en GitHub), software libre de licencia MIT. Las temperaturas y presiones de la tabla las eligió Simuveliq; ninguna tabla se copió de un libro.